1. Introduzzjoni
The IDEAL 61-747 TightSight clamp meter is a CAT III 600 V rated auto-ranging True Root Mean Square (TRMS) digital clamp meter. This instrument is designed for professional and accurate measurement of various electrical parameters in a wide range of applications. Its robust design and innovative features enhance safety and efficiency during electrical testing.

Figure 1.1: IDEAL 61-747 TightSight Clamp Meter with its unique secondary display.
2. Informazzjoni dwar is-Sigurtà
Always adhere to local and national safety codes. Use personal protective equipment (PPE) such as safety glasses and insulated gloves when working with electrical circuits. Ensure the meter is in good working condition before use. Do not exceed the maximum input ratings for any function. Disconnect power to the circuit before making connections for resistance, continuity, capacitance, or diode tests.
- CAT III 600V Rating: This meter is rated for Category III installations up to 600 Volts.
- Spezzjona qabel l-użu: Always inspect the meter, test leads, and accessories for any damage before each use. Do not use if damaged.
- Proper Function Selection: Ensure the correct function is selected for the measurement being performed.
- Mhux Kuntatt VoltagSensur e (NCV): The NCV sensor detects voltage between 40V and 600V. An illuminated red LED and audible tones indicate voltage preżenza.
3. Kontenut tal-Pakkett
Malli tiftaħ il-pakkett, ivverifika li l-oġġetti kollha elenkati hawn taħt huma preżenti u mhux imħassra:
- IDEAL 61-747 TightSight Clamp Miter
- Wavel tat-Test (Aħmar u Iswed)
- Termokoppja tat-Tip K
- 3 x 1.5V AAA Batteries (pre-installed or included separately)
- Soft Storage Pouch with Belt Loop
- Manwal għall-Utent (dan id-dokument)

Figure 3.1: The IDEAL 61-747 Clamp Meter and its standard accessories.
4. Karatteristiċi u Komponenti tal-Prodott
The IDEAL 61-747 clamp meter incorporates several features designed for ease of use, accuracy, and safety:
- Clamp Kap: Measures AC and DC current up to 400 Amps without breaking the circuit.
- TightSight LCD Display: A patented secondary display located at the bottom of the unit, allowing for easy reading in difficult positions.
- Wiri LCD Prinċipali: Primary display for all measurement readings.
- Dial tal-Funzjoni: Rotary switch to select measurement modes.
- Mhux Kuntatt VoltagSensur e (NCV): Integrated into the right tip of the clamp for detecting live voltage mingħajr kuntatt dirett.
- Flashlight inkorporat: Idawwal iż-żona tax-xogħol f'kundizzjonijiet ta' dawl baxx.
- Backlit Displays: Both the main and TightSight displays can be backlit for visibility in dark environments.
- Probe Tip Holder: Located on the backside of the right clamp for convenient single-hand operation with test leads.
- Hanging Strap Mount: Compatible with IDEAL hanging straps (sold separately) for hands-free operation.
- Industrial Grade Overmolding: Enhances grip and provides drop protection.

Figura 4.1: Quddiem view tal-clamp meter highlighting key components.

Figure 4.2: Detail of the integrated probe tip holder for convenience.
5. Setup
5.1 Installazzjoni tal-batterija
The meter operates on three 1.5V AAA batteries. To install or replace batteries:
- Kun żgur li l-miter ikun MITFI.
- Sib il-kompartiment tal-batterija fuq wara tal-miter.
- Uża tornavit biex tiftaħ l-għatu tal-kompartiment tal-batterija.
- Insert the 3 AAA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
- Ibdel l-għatu tal-kompartiment tal-batterija u waħħalha bil-kamin.
5.2 Konnessjoni tal-wajers tat-test
Għal voltage, resistance, continuity, capacitance, and diode measurements, connect the included test leads:
- Insert the red test lead into the V/Ω/CAP/Hz/°C input jack.
- Daħħal il-wajer tat-test iswed fil-jack tad-dħul COM (komuni).
6. Istruzzjonijiet Operattivi
6.1 Tixgħel/Jitfi
Rotate the function dial from the OFF position to any desired measurement function to power on the meter. To power off, rotate the dial back to the OFF position.
6.2 Funzjonijiet tal-Kejl
The 61-747 meter offers a variety of measurement capabilities:
- AC/DC Current (A~, A--): Uża l-clamp head to measure current up to 400 Amps. Open the clamp by pressing the lever, encircle a single conductor, and release the lever to close the clamp.
- AC / DC Voltage (V~, V--): Connect test leads to the circuit. Measures up to 600V.
- Reżistenza (Ω): Qabbad il-wajers tat-test mal-komponent.
- Kontinwità (♫): Connect test leads across the circuit. An audible tone indicates continuity.
- Kapaċità (CAP): Connect test leads across the capacitor.
- Test tad-diode (♫): Qabbad il-wajers tat-test mad-dijodu.
- Frekwenza (Hz): Can be measured in conjunction with voltage jew kurrenti.
- Temperature (°F/°C): Connect the K-Type thermocouple to the meter's input jacks.

Figure 6.1: Measuring current with the clamp meter, demonstrating the TightSight display.
6.3 Funzjonijiet Speċjali
- TightSight Display: The secondary display at the bottom of the meter mirrors the main display, providing an alternative viewangolu tal-ing.
- Mhux Kuntatt Voltage (NCV): Select the NCV function. Place the right tip of the clamp near a live conductor. The red LED in the center of the meter will illuminate and an audible tone will sound if voltage is detected (40V-600V).
- Dawl ta' wara: Press the backlight button (often combined with flashlight button) to illuminate the displays for better visibility in dim conditions.
- Flashlight: Press the flashlight button to activate the built-in flashlight.
- ŻOMM: Jiffriża l-qari attwali fuq id-displej.
- MIN / MAX: Records the minimum and maximum readings over a period.
- RELATIVE (REL): Measures the difference between a stored reference value and the current reading.
- ŻERO: Used to zero out the display for DC current measurements to remove residual magnetism.
- FIRXA: Jaqleb bejn il-modi ta' kejl awtomatiku tal-firxa u l-modi ta' kejl manwali tal-firxa.
- Mitfi Awtomatiku: The meter will automatically power off after a period of inactivity to conserve battery life. This feature can typically be disabled if needed (refer to the full user manual for specific instructions).

Figure 6.2: Using the Non-Contact Voltage (NCV) sensor.

Figure 6.3: The built-in flashlight illuminating the work area.
7. Manutenzjoni u Kura
Proper maintenance ensures the longevity and accuracy of your clamp metru:
- Tindif: Imsaħ il-miter b'reklamaramp cloth and mild detergent. Do not use abrasives or solvents. Ensure the meter is dry before storage or use.
- Sostituzzjoni tal-batterija: Replace batteries when the low battery indicator appears on the display. Remove batteries if the meter will not be used for an extended period.
- Ħażna: Store the meter in its soft storage pouch in a cool, dry place, away from direct sunlight and extreme temperatures.
- Kalibrazzjoni: Għal użu professjonali, huwa rakkomandat kalibrazzjoni perjodika minn ċentru ta' servizz kwalifikat biex tinżamm l-eżattezza.
8 Issolvi l-problemi
If you encounter issues with your IDEAL 61-747 clamp meter, refer to the following common problems and solutions:
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Il-miter ma jixgħelx. | Batteriji mejta jew installati ħażin. | Check battery polarity; replace with new 1.5V AAA batteries. |
| No reading or unstable reading. | Incorrect function selected; poor test lead connection; out of range. | Ensure correct function; check test lead connections; verify measurement is within meter's range. |
| NCV sensor not detecting voltage. | Voltage below detection threshold (40V); sensor not close enough to conductor. | Tiżgura voltage is within 40V-600V range; position sensor closer to the live conductor. |
| Id-displej huwa mċajpar jew qed jitteptep. | Batterija baxxa. | Ibdel il-batteriji. |
9. Speċifikazzjonijiet
Key technical specifications for the IDEAL 61-747 Clamp Miter:
| Parametru | Valur |
|---|---|
| Numru tal-Mudell | 61-747 |
| Dimensjonijiet tal-Prodott | 10 x 6 x 2 pulzieri |
| Piż tal-oġġett | 1.41 Liri |
| Manifattur | IDEALI |
| Sors tal-Enerġija | Battery Powered (3 x 1.5V AAA) |
| Stil | Diġitali |
| Kulur | Aħmar |
| Kejl tal-Kurrent AC/DC | Sa 400 Amps |
| AC / DC Voltage Kejl | Sa 600 Volt |
| Mhux Kuntatt Voltage Medda ta' Sejbien | 40V sa 600V |
| Temperature Measurement Range (Tester) | -40°F sa 1832°F (-40°C sa 1000°C) |
| Temperature Measurement Range (K-Type Thermocouple) | -40°C sa 250°C (-40°F sa 482°F) |
| Klassifikazzjoni tas-Sigurtà | CAT III 600V |
| Tip ta 'Wiri | Digital, 4000 Count, Dual Backlit Displays |
| Karatteristiċi | True RMS, TightSight Display, Flashlight, Probe Tip Holder, Hanging Strap Mount, Hold, Min/Max, Relative, Zero, Range, Auto Power Off |
10. Garanzija u Appoġġ
For detailed warranty information and customer support, please refer to the official IDEAL Electrical documentation or contact IDEAL customer service.