2gig 2GIG-STZ-1

2GIG Z-Wave 700 Programmable Thermostat (Model 2GIG-STZ-1) User Manual

Model: 2GIG-STZ-1 | Brand: 2GIG

1. Introduzzjoni

This manual provides comprehensive instructions for the installation, operation, and maintenance of your 2GIG Z-Wave 700 Programmable Thermostat, Model 2GIG-STZ-1. This device allows for remote control of your heating and air conditioning systems via a Z-Wave network, in addition to direct control from the thermostat unit.

The 2GIG-STZ-1 thermostat is compatible with most modern HVAC systems, including standard Gas/Electric (2-stage tisħin, 2-stage cooling) and Heat Pump systems (3-stage tisħin, 2-stage cooling), with support for humidifiers and dehumidifiers.

2GIG Z-Wave 700 Programmable Thermostat front view

Figura 1: Quddiem view of the 2GIG Z-Wave 700 Programmable Thermostat, displaying current temperature, fan status, and time.

Karatteristiċi ewlenin:

2. Informazzjoni dwar is-Sigurtà

Please read all instructions carefully before installing or operating this thermostat. Failure to follow these instructions could result in property damage, injury, or death.

3. Kontenut tal-Pakkett

Ivverifika li l-oġġetti kollha huma preżenti fil-pakkett:

4. Installazzjoni

4.1. Tħejjija għall-Installazzjoni

  1. Turn off power to your heating and cooling system at the main circuit breaker.
  2. Remove your old thermostat's cover. Take a picture of the wiring connections for reference.
  3. Label each wire with the corresponding terminal letter from your old thermostat.
  4. Disconnect the wires and remove the old thermostat's mounting plate.

4.2. Mounting the Back Panel

The back panel of the 2GIG-STZ-1 thermostat serves as the mounting base and wiring terminal.

  1. Feed the wire cable from the wall through the access hole in the new mounting plate.
  2. Use the provided wall anchors and two Phillips screws to secure the back panel to the wall.
  3. Ensure the back panel is level for proper aesthetic alignment.
Diagram showing how to mount the thermostat back panel and feed wires

Figure 2: Illustration of mounting the back panel, showing wire access and screw locations.

4.3. Il-wajers tat-Termostat

Connect the labeled wires to the corresponding terminals on the thermostat's back panel. Refer to your old thermostat's wiring diagram and the labels you made. The 2GIG-STZ-1 supports the following configurations:

For 24VAC power, ensure both "R" and "C" wires are connected. If a "C" wire is not available, the thermostat can be powered by 4 AA batteries, but it will not repeat Z-Wave signals in your network.

4.4. It-twaħħil tal-Panew ta 'quddiem

Once wiring is complete, attach the thermostat's front panel to the mounted back panel.

  1. Align the front panel with the back panel.
  2. Gently press the front panel onto the back panel until it snaps securely into place around all edges.
Diagram showing how to attach the thermostat front panel to the back panel

Figure 3: Illustration of attaching the front panel to the back panel, showing the snap-together mechanism.

After the front panel is attached, restore power to your HVAC system at the circuit breaker.

5. Istruzzjonijiet Operattivi

5.1. L-Ixgħel tat-Termostat

The thermostat can be powered by 24VAC from your HVAC system (if "R" and "C" wires are connected) or by four (4) AA batteries. If 24VAC is supplied, batteries are not required for operation but can serve as a backup. If only battery-powered, the thermostat will not function as a Z-Wave repeater.

5.2. Kontrolli Bażiċi

The thermostat features a clear LCD display and intuitive buttons for control:

5.3. Aġġusta tat-Temperatura

Agħfas il- Up or Down arrow buttons to increase or decrease the desired temperature setpoint. The display will show the new setpoint temporarily.

5.4. Z-Wave Network Integration

To integrate the thermostat into your Z-Wave network, refer to your Z-Wave hub's instructions for adding new devices. The 2GIG-STZ-1 is a Z-Wave 700 series device, offering enhanced range and battery life. Once paired, you can control the thermostat remotely via your Z-Wave smart device or hub interface.

Nota: For optimal Z-Wave performance and to function as a Z-Wave repeater, the thermostat should be powered by 24VAC.

6. Manutenzjoni

6.1. Tindif tat-Termostat

Biex tnaddaf it-termostat, imsaħ bil-mod il-barra b'ċarruta ratba u damp cloth. Do not use abrasive cleaners, solvents, or spray cleaners directly onto the thermostat, as this may damage the unit or its electronic components.

6.2. Sostituzzjoni tal-batterija

If your thermostat is battery-powered, replace the four (4) AA batteries when the low battery indicator appears on the display. Ensure to use fresh, high-quality alkaline batteries. If the thermostat is 24VAC powered, battery replacement is not typically required for operation, but batteries can be installed for backup power.

  1. Carefully remove the front panel of the thermostat from the back panel.
  2. Neħħi l-batteriji AA qodma.
  3. Insert four new AA batteries, ensuring correct polarity (+/-).
  4. Reattach the front panel to the back panel until it snaps securely.

7 Issolvi l-problemi

If you encounter issues with your 2GIG-STZ-1 thermostat, refer to the following common problems and solutions:

ProblemaKawża PossibbliSoluzzjoni
Thermostat has no power/blank display.No 24VAC power; dead batteries; incorrect wiring.Check circuit breaker for HVAC system. Replace AA batteries if battery-powered. Verify "R" and "C" wire connections.
Is-sistema HVAC mhux qed tirrispondi għat-termostat.Incorrect wiring; system mode set to "Off"; Z-Wave communication issue.Double-check wiring. Ensure system mode is set to "Heat", "Cool", or "Auto". Re-pair with Z-Wave network if controlling remotely.
Temperature swing is too wide.Thermostat differential settings.Consult the advanced settings menu (if available) or your Z-Wave controller for options to adjust temperature differential. This setting controls how far the temperature deviates from the setpoint before the system activates.
Ma nistax nikkonnettja man-netwerk Z-Wave.Thermostat too far from hub; interference; incorrect pairing procedure.Ensure thermostat is within range of the Z-Wave hub or a repeater. Follow Z-Wave hub's specific instructions for inclusion/exclusion. Ensure thermostat is 24VAC powered to act as a repeater.

8. Speċifikazzjonijiet

KaratteristikaDettall
Numru tal-Mudell2GIG-STZ-1 (also known as 2GIG-STZ1-345)
Kompatibilità24VAC 3H/2C non-heat pump/heat pump systems with humidifier/dehumidifier support. Not compatible with 120/240 VAC systems.
Room Temperature Measurement ScaleFahrenheit / Celsius (user selectable)
Firxa tat-Temperatura tal-Kamra32 sa 122 grad F (0 sa 50 grad C)
Preċiżjoni tat-Temperatura+/- 1 degrees F (0.5 degrees C)
Heat Set Point Range32 - 90 degrees F (0 - 32 degrees C)
Cool Set Point Range61 - 122 degrees F (16 - 50 degrees C)
Setting Reżoluzzjoni1 grad F (0.5 grad C)
Kontroll tal-fannAwto/Mixgħul
Provvista tal-EnerġijaAC: 18-26VAC 60Hz (R and C); 4x AA size battery (6VDC)
Firxa tat-Temperatura Operattiva32 sa 122 grad F (0 sa 50 grad C)
Umdità Operattiva10-90 percent Non-Condensing
Dimensjonijiet (H x W x D)5.75 x 4.5 x 1 pulzieri (14.6 x 11.4 x 2.5 ċm)
Piż1.06 lbs (0.48 kg)
KonnettivitàZ-Wave (serje 700)
Tip ta 'WiriLCD b'lura ta 'wara

9. Informazzjoni dwar Garanzija

The 2GIG Z-Wave 700 Programmable Thermostat (Model 2GIG-STZ-1) comes with a Garanzija Limitata ta' Sena from the manufacturer. Please retain your proof of purchase for warranty claims. For specific terms and conditions, refer to the warranty documentation included with your product or contact 2GIG customer support.

10. Appoġġ għall-Klijent

For further assistance, technical support, or warranty inquiries, please contact 2GIG customer support. You may also refer to the support resources provided by your Z-Wave hub manufacturer for integration-specific questions.

Nota: Manufacturer support policies may vary. Access to detailed manuals or direct support might be restricted to authorized dealers or installers in some cases.

Dokumenti Relatati - 2GIG-STZ-1

Preview Katalgu tal-Prodotti tas-Sigurtà u l-Awtomazzjoni 2GIG
Katalogu komprensiv ta' prodotti tas-sigurtà u tal-awtomazzjoni tad-dar 2GIG, inklużi pannelli tal-kontroll, tastieri, sensuri, kameras, u apparati Z-Wave. Jinkludi speċifikazzjonijiet dettaljati u informazzjoni dwar il-prodott.
Preview 2GIG Z-Wave Plus V2 Thermostat (2GIG-STZ-1) Quick Start Guide
Quick start guide for installing and setting up the 2GIG Z-Wave Plus V2 Thermostat (Model 2GIG-STZ-1), covering wiring, mounting, Z-Wave pairing, and system mode configuration.
Preview Gwida għall-Utent tat-Termostat li Jaħdem bil-Batterija 2GIG Z-Wave Plus v2
Esplora t-Termostat li Jaħdem bil-Batterija 2GIG Z-Wave Plus v2 b'din il-gwida komprensiva għall-utent u l-installazzjoni. Tgħallem dwar l-integrazzjoni tad-dar intelliġenti, il-kompatibilità tas-sistema HVAC, is-setup, u t-tħaddim minn Nortek Security & Control.
Preview Gwida għall-Utent tat-Termostat li Jaħdem bil-Batterija 2GIG Z-Wave Plus v2
Gwida komprensiva għall-utent għat-Termostat li jaħdem bil-Batterija 2GIG Z-Wave Plus v2, li tiddeskrivi l-installazzjoni, is-setup tas-sistema, il-modi ta' tħaddim, l-integrazzjoni ta' Z-Wave, is-settings avvanzati, u l-ispeċifikazzjonijiet għall-awtomazzjoni tad-dar intelliġenti.
Preview 2GIG-PIR1-345 Passive Infrared Motion Detector Installation and Operating Instructions
Comprehensive guide for the 2GIG-PIR1-345 Passive Infrared Motion Detector, covering installation, setup, pet immunity features, testing, environmental considerations, and technical specifications.
Preview Istruzzjonijiet dwar l-Operazzjoni tal-Boċċa tal-Paniku 2GIG-PANIC1-345
Istruzzjonijiet tat-tħaddim, linji gwida għall-installazzjoni, programmazzjoni, ittestjar, u sostituzzjoni tal-batterija għar-remote bil-buttuna tal-paniku 2GIG-PANIC1-345. Jinkludi speċifikazzjonijiet u informazzjoni dwar il-konformità mal-FCC.