Model: BK171UL

1. Introduzzjoni

This manual provides detailed instructions for the installation, operation, and maintenance of the Beckett BK171UL Condensate Pump. This pump is designed for automatic removal of condensate from HVAC equipment, including air conditioners, furnaces, boilers, dehumidifiers, and high-efficiency oil or gas-fired furnaces. It is suitable for condensate water temperatures up to 150°F and acidic condensate.

Beckett BK171UL Condensate Pump

Image 1.1: Beckett BK171UL Condensate Pump, front view.

2. Informazzjoni dwar is-Sigurtà

TWISSIJA: Riskju ta' Xokk Elettriku. Skonnettja l-provvista tal-enerġija qabel ma tagħmel manutenzjoni.

  • Aqra l-istruzzjonijiet kollha bir-reqqa qabel l-installazzjoni u t-tħaddim.
  • Kun żgur li l-provvista tal-enerġija taqbel mal-volum tal-pompatage (115V).
  • Tħaddimx il-pompa b'korda jew plagg bil-ħsara.
  • Do not immerse the pump in water.
  • This pump is designed for indoor use only.
  • Żomm idejk 'il bogħod minn partijiet li jiċċaqilqu waqt it-tħaddim.
  • Żgura ertjar xieraq skont il-kodiċijiet elettriċi lokali.
  • The pump is equipped with a safety switch. Ensure it is correctly wired to prevent overflow.

3. Kontenut tal-Pakkett

Iċċekkja li l-komponenti kollha huma preżenti qabel tibda l-installazzjoni:

  • Beckett BK171UL Condensate Pump unit
  • 3/8" O.D. barbed check valve
  • Integrated 6-ft grounded power cord
  • Manwal ta 'Istruzzjoni (dan id-dokument)
Sploda view of Beckett BK171UL Condensate Pump components

Immaġni 3.1: Splodiet view showing pump components including cover, check valve, motor, fan, automatic switches, lift-to-test tab, bullseye level, floats, impeller, multi-slot metal mount tabs, 6 ft. grounded power cord, and collection tank.

4. Installazzjoni u Setup

4.1 Immuntar tal-Pompa

The pump features stainless steel multi-slot mounting tabs for secure installation. Ensure the pump is placed on a level surface. Use the integrated bullseye level on the lid to confirm proper horizontal alignment.

Beckett BK171UL Condensate Pump installation features

Image 4.1: Close-up of pump showing bullseye level, twist lock check valve, and lift-to-test tab for easy installation and maintenance.

4.2 Condensate Inlet Connections

The pump is equipped with four 1-1/8-inch diameter inlet holes for connecting condensate drain lines from your HVAC equipment. Connect the drain line(s) to any available inlet(s).

4.3 Discharge Line Connection

Connect a 3/8" I.D. vinyl tubing (not included) to the 3/8" O.D. barbed check valve. The check valve twists to lock into place on the pump, preventing backflow of discharged water. Route the discharge line to an appropriate drain, ensuring it has a continuous downward slope and is free from kinks or obstructions. The pump can lift water up to 17 feet vertically.

4.4 Konnessjoni Elettrika

Plug the 6-ft grounded power cord into a standard 115V electrical outlet. Ensure the outlet is properly grounded and protected by a ground fault circuit interrupter (GFCI) if required by local codes.

4.5 Safety Switch Wiring

The integrated safety switch is designed to shut down the HVAC equipment or trigger an alarm in case of a pump malfunction or high water level, preventing overflow. Consult your HVAC equipment manual for proper wiring of the safety switch. Typically, the safety switch wires are connected in series with the low-voltage thermostat circuit of the HVAC unit.

5. Operazzjoni

5.1 Automatic On/Off Operation

The Beckett BK171UL pump operates automatically. When condensate water in the collection tank reaches a predetermined level, the pump will activate, remove the water, and then shut off once the water level drops. This automatic cycle ensures efficient condensate removal without constant monitoring.

Beckett BK171UL Condensate Pump performance chart

Image 5.1: Diagram illustrating automatic ON/OFF operation and average performance at various lift heights (e.g., 95 GPH at 5 ft lift, 64 GPH at 10 ft lift, 17 ft shut-off).

5.2 Lift-to-Test Function

A "lift-to-test" tab is provided on the pump lid. Lifting this tab manually raises the float, simulating a high water level and activating the pump. This feature allows for quick testing of the pump's functionality and can also be used to drain the tank for servicing.

6. Manutenzjoni

Manutenzjoni regolari tiżgura prestazzjoni ottimali u testendi l-ħajja tal-pompa tal-kondensat tiegħek.

  • Spezzjoni ta' Kull Xahar: Visually inspect the pump, inlet, and discharge lines for any blockages, leaks, or damage. Ensure the discharge line is free of kinks.
  • Tindif Kull Tliet Xhur:
    1. Disconnect power to the pump and the HVAC unit.
    2. Use the lift-to-test tab to drain the tank, or manually remove any remaining water.
    3. Carefully remove the pump cover.
    4. Clean the collection tank, floats, and impeller area to remove any sludge, debris, or mineral deposits. A mild detergent and soft brush can be used.
    5. Laħlaħ il-komponenti kollha sewwa b'ilma nadif.
    6. Reassemble the pump, ensuring the cover is securely in place.
    7. Reconnect power and test the pump using the lift-to-test tab.
  • Linja ta' Skariku: Periodically check the discharge line for algae or mineral buildup, especially if the pump is handling acidic condensate. Clean or replace the tubing as necessary.

7 Issolvi l-problemi

ProblemaKawża PossibbliSoluzzjoni
Il-pompa ma taħdimxEbda enerġija għall-pompaCheck power cord connection, circuit breaker, and GFCI.
Float switch stuck or obstructedDisconnect power, remove cover, clean floats and tank.
Il-pompa taħdem imma ma toħroġx ilmaDischarge line clogged or kinkedInspect and clear the discharge line. Ensure no kinks.
Check valve obstructedDisconnect power, remove and clean the check valve.
Impeller misdudaDisconnect power, remove cover, clean impeller area.
Il-pompa taħdem kontinwamentIs-swiċċ tal-galleġġjant imwaħħal fil-pożizzjoni "mixgħul"Disconnect power, remove cover, clean floats and tank.
Leak in discharge line or check valveInspect all connections and the discharge line for leaks. Tighten or replace as needed.
Il-pompa hija storbjużaDebris in impeller or motorDisconnect power, remove cover, clean impeller area.
Il-pompa mhix livellataAdjust pump placement using the bullseye level.

8. Speċifikazzjonijiet

  • Mudell: BK171UL
  • Voltage: 115V
  • Maximum Lift: 17 pied
  • Rata tal-fluss: 112 GPH @ 1 ft lift
  • Ampetà: 1.1 Amps
  • Wattage: 60 Watts
  • Frekwenza: 60 HZ
  • Collection Tank Capacity: 2.5 Quarts
  • Konnessjoni tal-Ħruġ: 3/8" O.D. barbed check valve
  • Konnessjonijiet tad-daħla: Four 1-1/8" diameter holes
  • Korda tal-Enerġija: 6 ft grounded with plug
  • Maximum Condensate Water Temperature: 150°F
  • Materjal: Acrylonitrile Butadiene Styrene (ABS), plastik
  • Dimensjonijiet (L x W x H): 11.2" x 5.2" x 6.6"
  • Piż tal-oġġett: 3.7 Liri
  • Karatteristiċi tas-Sigurtà: Integrated safety switch, Thermally protected motor
  • Ċertifikazzjonijiet: UL/cUL listed in U.S./Canada
Beckett BK171UL Condensate Pump dimensions

Image 8.1: Dimensions of the Beckett BK171UL Condensate Pump.

9. Garanzija u Appoġġ

The Beckett BK171UL Condensate Pump comes with a Garanzija tal-manifattur ta 'sena. For warranty claims, technical assistance, or replacement parts, please contact Beckett Corporation customer support. Keep your purchase receipt as proof of purchase.

For further assistance, please refer to the official Beckett Corporation websit jew ikkuntattja lid-dipartiment tas-servizz tal-konsumatur tagħhom.

Dokumenti Relatati - BK171UL

Preview Pompa tal-Kondensat Awtomatika Beckett CB22: Manwal tal-Installazzjoni, Tħaddim u Sigurtà
Manwal komprensiv tas-sid għall-Unità Awtomatika tal-Kondensat Beckett CB22. Jinkludi struzzjonijiet dettaljati għall-installazzjoni, tħaddim sikur, wajers, manutenzjoni, issolvi l-problemi, u informazzjoni dwar il-garanzija limitata.
Preview Gwida għall-Installazzjoni u l-Manutenzjoni tal-Pompa għat-Tneħħija tal-Kondensat Beckett BK17/BK22
Din il-gwida tipprovdi struzzjonijiet dettaljati dwar l-installazzjoni, il-manutenzjoni u s-sigurtà għall-pompi tat-tneħħija tal-kondensat Beckett BK17 u BK22, inkluż informazzjoni dwar il-garanzija u l-ispeċifikazzjonijiet tal-prestazzjoni.
Preview Beckett Automatic Condensate Removal Pump Installation and Operation Manual
This manual provides comprehensive installation, operation, wiring, testing, and troubleshooting guidance for Beckett Automatic Condensate Removal Pumps, including models CL201UL, CL202UL, CL202ULHT, and CL202CE. It details warranty information and maintenance procedures.
Preview Gwida ta' Referenza Rapida għall-Kontroll tal-Bojler Beckett AquaSmart 7600
Gwida ta' referenza rapida u konċiża għall-kontroll tal-bojler Beckett AquaSmart tas-Serje 7600, li tkopri l-ispeċifikazzjonijiet tekniċi, l-installazzjoni, il-programmazzjoni bażika, u d-dijagrammi tal-wajers, flimkien ma' informazzjoni dwar il-garanzija.
Preview Manwal tal-Installazzjoni u t-Tħaddim tal-Kontroll Avvanzat tal-Bojler Beckett AquaSmart Mudell 7600
Gwida komprensiva għas-sistema ta' kontroll tal-bojler Beckett AquaSmart Mudell 7600, li tkopri l-installazzjoni, il-wajers, l-ipprogrammar, karatteristiċi bħal HeatManager™, u s-soluzzjoni tal-problemi għal applikazzjonijiet residenzjali u kummerċjali ħfief.
Preview Kontroll tal-Bojler Beckett AquaSmart 7610: Folja tal-Prodott u Speċifikazzjonijiet
Folja komprensiva tal-prodott għall-Kontroll tal-Bojler Beckett AquaSmart 7610. Tiddeskrivi l-karatteristiċi, il-benefiċċji, il-funzjonalità HeatManager™, reset mingħajr fili fakultattiv, informazzjoni dwar l-ordnijiet, dijagrammi tal-wajers, klassifikazzjonijiet elettriċi, speċifikazzjonijiet tat-temperatura, u klassifikazzjonijiet ambjentali. Tinkludi n-numri tal-partijiet għas-sensuri u l-aċċessorji.