Introduzzjoni
This manual provides detailed instructions for the installation, operation, and maintenance of your IMI HEIMEIER Thermostatic Head and Valve Set. Please read these instructions carefully before installation and use to ensure proper function and safety. This set is designed for precise temperature control in heating systems.
Komponenti tal-Prodott
The IMI HEIMEIER Thermostatic Head and Valve Set typically includes the following components:
- Kap termostatiku: M30 x 1.5 connection, with a temperature setting range of 6 °C to 28 °C. This component senses room temperature and adjusts the valve accordingly.
- Thermostat Valve: Heimeier Calypso 1/2 inch. This valve regulates the flow of heating water to the radiator.
- Return Screw Connection: Corner shape, for connecting the return pipe.

Immaġni 1: Fuqview of the IMI HEIMEIER Thermostatic Head and Valve Set, showing the white thermostatic head and two metallic valve components.
Setup u Installazzjoni
Installation should be performed by a qualified professional. Ensure the heating system is depressurized and cooled before beginning installation.
- Prepare the Radiator: Ensure the existing valve is removed and the pipe connections are clean and free of debris.
- Install the Thermostat Valve: Screw the Heimeier Calypso 1/2 inch thermostat valve into the flow pipe connection of the radiator. Use appropriate sealing materials (e.g., PTFE tape or hemp) to ensure a watertight connection.
- Install the Return Screw Connection: Attach the corner-shaped return screw connection to the return pipe of the radiator. Again, ensure proper sealing.
- Attach the Thermostatic Head: Once the valve body is securely installed, align the thermostatic head (M30 x 1.5) with the valve body. Screw the head onto the valve body until it is hand-tight. Do not overtighten.

Immaġni 2: Mill-qrib view of the two metallic valve components, showing their threaded connections.

Immaġni 3: Mill-qrib view of the white IMI HEIMEIER Thermostatic Head, showing the M30 x 1.5 connection and temperature markings.
Istruzzjonijiet Operattivi
The thermostatic head allows you to set the desired room temperature. The markings on the head correspond to different temperature ranges:
- Snowflake Symbol (Frost Protection): Approximately 6 °C. Prevents the room from freezing.
- Settings 1 to 5: Correspond to increasing temperatures, typically from 12 °C to 28 °C. Each number represents an approximate temperature setting.
To adjust the temperature, simply rotate the thermostatic head to the desired setting. The head will automatically regulate the hot water flow to maintain the selected room temperature.
Manutenzjoni
The IMI HEIMEIER Thermostatic Head and Valve Set requires minimal maintenance. Regular checks can ensure optimal performance:
- Tindif: Wipe the thermostatic head with a soft, damp drapp. Tużax tindif jew solventi li joborxu.
- Iċċekkja tal-Funzjoni: Periodically rotate the head through its full range of settings to ensure smooth operation and prevent sticking, especially before the heating season.
- Spezzjoni tat-tnixxija: Visually inspect the valve connections for any signs of water leakage. Address any leaks immediately.
Issolvi l-problemi
If you experience issues with your thermostatic head and valve set, consider the following common problems and solutions:
- Radiator Not Heating:
- Ensure the thermostatic head is set to a high enough temperature.
- Check if the valve pin is stuck. Remove the thermostatic head and gently press the pin on the valve body. It should move freely. If stuck, try to free it by gently tapping or lubricating.
- Verify that the main heating system is operational and there is hot water circulation.
- Radiator Always Hot (Even on Low Setting):
- The valve pin might be stuck in the open position. Follow the steps above to check and free the pin.
- Ensure the thermostatic head is correctly mounted and fully engaged with the valve body.
- Tnixxijiet fil-Konnessjonijiet:
- Tighten connections carefully, ensuring not to overtighten.
- If tightening does not resolve the issue, the sealing material may need to be replaced. This should be done by a qualified professional.
For persistent issues, contact a qualified heating technician.
Speċifikazzjonijiet
| Manifattur | IMI HEIMEIER |
| Numru tal-Mudell | xc |
| ASIN | B08HS8P3BT |
| Thermostatic Head Connection | M30 x 1.5 |
| Firxa tal-issettjar tat-temperatura | 6°C - 28°C |
| Thermostat Valve Size | 1/2 inch (Heimeier Calypso) |
| Return Connection Type | Corner shape |
| Dimensjonijiet tal-Pakkett | 5.2 x 4.49 x 2.64 pulzieri |
| Piż tal-oġġett | 1.11 liri |
| Batteriji Meħtieġa | Nru |
Informazzjoni dwar is-Sigurtà
- Always ensure the heating system is depressurized and cooled before attempting any installation or maintenance.
- Installation should only be carried out by competent individuals or qualified professionals.
- Do not use excessive force when tightening connections to avoid damaging components.
- Żomm il-materjali tal-ippakkjar 'il bogħod mit-tfal biex tevita perikli ta' soffokazzjoni.