Introduzzjoni

Immaġni: Star 025191 High Performance Pool Pump. This image displays the complete pool pump unit, highlighting its compact design and key components like the motor, pump housing, and transparent strainer lid.
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Star 025191 High Performance Pool Pump. This pump is designed for use with in-ground or above-ground swimming pools up to 53,000 gallons, ensuring water clarity and hygiene. Please read this manual thoroughly before installation and operation.
The Star 025191 pump features a 1.5 HP single-speed motor, factory-wired for 230 Volts, and is constructed from corrosion-resistant thermoplastic for durability. It delivers a high volume flow rate of up to 110 GPM at 20’ TDH for efficient water circulation to filtration systems.
Istruzzjonijiet Importanti dwar is-Sigurtà
Meta tinstalla u tuża dan it-tagħmir elettriku, għandhom dejjem jiġu segwiti prekawzjonijiet bażiċi tas-sigurtà, inklużi dawn li ġejjin:
- Aqra u segwi l-istruzzjonijiet kollha.
- PERIKLU: Risk of electrical shock. Connect only to a grounded receptacle protected by a ground-fault circuit interrupter (GFCI).
- TWISSIJA: Biex tnaqqas ir-riskju ta' korriment, tħallix lit-tfal jużaw dan il-prodott.
- TWISSIJA: Din il-pompa hija għal installazzjoni permanenti biss. Tużax ma' pixxini li jistgħu jinħażnu.
- Ensure the electrical supply matches the pump's voltage requirements (115V or 230V). The pump is factory-wired for 230V.
- All wiring must be performed by a qualified electrician and comply with local codes and regulations.
- Always disconnect power to the pump before servicing or performing maintenance.
- Do not operate the pump if it has been damaged in any way.
- Keep all connections dry and away from water.
Kontenut tal-Pakkett
Ivverifika li l-komponenti kollha huma preżenti fil-pakkett qabel tibda l-installazzjoni.

Immaġni: Package Contents Diagram. This illustration details the main pump unit (A) and the included connection accessories: 2-inch slip union adapters (B), 1.5-inch slip union adapters (C), and couplings (D).
| Oġġett | Deskrizzjoni | Kwantità |
|---|---|---|
| A | Star 025191 Pool Pump | 1 |
| B | 2" Slip Union Adapters | 2 |
| C | 1.5" Slip Union Adapters | 2 |
| D | Couplings | 2 |
Setup u Installazzjoni
Proper installation is crucial for the pump's performance and longevity. Refer to the installation diagram and follow these steps carefully.
1. L-Għażla tas-Sit
- Install the pump as close to the pool as possible to minimize friction loss from long suction lines.
- Ensure the pump is installed on a firm, level base that can support its weight and prevent vibration.
- Provide adequate ventilation around the motor for cooling.
- Protect the pump from excessive moisture and direct sunlight.
2. Konnessjonijiet tal-plaming
The pump is designed to connect to either 1.5-inch or 2-inch pipe using the included slip union adapters and couplings.
- Apply thread sealant to all threaded connections to ensure a watertight seal.
- Connect the appropriate slip union adapters (1.5" or 2") to the pump's inlet and outlet ports.
- Use the couplings to connect the pump to your existing pool plumbing. Ensure all connections are tight to prevent air leaks, especially on the suction side.

Immaġni: Installation Diagram and Performance Data. This image provides a visual guide for connecting the pump to an in-ground pool system and includes a table detailing the pump's flow rate (GPM) at various Total Dynamic Head (TDH) levels.
3. Konnessjonijiet elettriċi
The Star 025191 pump is factory-wired for 230 Volts. If your electrical supply is 115 Volts, consult a qualified electrician for proper rewiring. The pump includes a 3 ft pigtail cord with ring terminals for connection.
- Ensure the power supply is disconnected at the circuit breaker before making any electrical connections.
- Connect the pump's pigtail cord to a dedicated circuit protected by a Ground-Fault Circuit Interrupter (GFCI).
- All electrical connections must comply with national and local electrical codes.
Istruzzjonijiet Operattivi
1. L-Ipprajmar tal-Pompa
Before starting the pump for the first time, or after the pump has been drained, it must be primed.
- Ensure the pool water level is adequate.
- Open all suction and return valves in the pool plumbing system.
- Remove the transparent strainer cover and fill the strainer basket housing with water until it overflows.
- Replace the strainer cover, ensuring it is securely tightened to prevent air leaks.
- Turn on the power to the pump. The pump should begin to draw water and expel air from the return lines.
- If the pump does not prime within 5 minutes, turn it off, re-prime, and check for air leaks in the suction line.
2. Operazzjoni Normali
- Once primed, the pump will operate continuously, circulating water through your filtration system.
- Monitor the pressure gauge on your filter (if applicable) to ensure it is within the normal operating range. An unusually high pressure reading may indicate a dirty filter or blockage.
- Regularly check the transparent strainer cover to see if the basket needs cleaning.
Manutenzjoni
Regular maintenance ensures optimal performance and extends the life of your pool pump.
1. Cleaning the Strainer Basket
The large strainer basket is designed to collect debris before it reaches the pump impeller. The transparent cover allows for easy visual inspection.
- Turn off the pump and disconnect power at the circuit breaker.
- Rotate the transparent strainer cover counter-clockwise to remove it.
- Lift out the strainer basket and empty any collected debris.
- Laħlaħ il-basket sewwa bl-ilma.
- Inspect the O-ring on the strainer cover for cracks or wear. Replace if necessary.
- Poġġi l-basket nadif lura fil-kaxxa, waqt li tiżgura li jkun imqiegħed sew.
- Replace the strainer cover, tightening it clockwise until snug. Do not overtighten.
- Re-prime the pump as described in the "Operating Instructions" section.
2. Preparazzjoni għax-xitwa
If you live in an area where temperatures drop below freezing, proper winterization is essential to prevent damage.
- Itfi l-pompa u skonnettja l-enerġija.
- Drain all water from the pump by removing the drain plugs (if applicable) or by disconnecting plumbing.
- Store the pump in a dry, protected area, or cover it securely if it must remain outdoors.
Issolvi l-problemi
This section addresses common issues you might encounter with your pool pump. For problems not listed here, contact customer support.
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Il-pompa ma tibdax | No power; tripped circuit breaker/GFCI; faulty motor. | Check power supply; reset breaker/GFCI; consult electrician. |
| Pump runs but does not prime or moves little water | Air leak in suction line; low water level; clogged strainer basket; closed valves. | Check all connections for leaks; ensure adequate pool water level; clean strainer basket; open all valves. |
| Ħsejjes jew vibrazzjonijiet eċċessivi | Air leak; cavitation; worn bearings; debris in impeller. | Check for air leaks; ensure proper water flow; contact service for worn parts. |
| Ilma inixxi mill-pompa | Loose connections; worn O-rings/seals; cracked housing. | Tighten connections; replace O-rings/seals; contact service for housing damage. |
Speċifikazzjonijiet
Detailed technical specifications for the Star 025191 High Performance Pool Pump.

Immaġni: Product Dimensions and Specifications. This image provides a detailed technical drawing with key dimensions of the pump and a table summarizing its electrical and performance characteristics.
| Speċifikazzjoni | Valur |
|---|---|
| Numru tal-Mudell | 025191 |
| Horsepower (HP) | 1.5 HP |
| Tip ta' Mutur | Veloċità Unika |
| Voltage | 115/230V (Factory wired for 230V) |
| Fażi | 1 |
| Rata tal-Fluss (Massima) | 110 GPM @ 20' TDH (6,000 GPH) |
| Materjal | Corrosion-resistant Thermoplastic |
| Daqs tal-Ħatt | 1.5" or 2" (adapters included) |
| Tul tal-kurdun | 3 ft pigtail with ring terminals |
| Protezzjoni Termali | Iva |
| Dimensjonijiet ġenerali | 26.5" x 9.45" x 12.6" |
| Piż | Madwar 50 lbs (22.6 kg) |
| UPC | 054757100056 |
Garanzija
The Star 025191 High Performance Pool Pump is covered by a Garanzija limitata ta 'sena mid-data tax-xiri. Din il-garanzija tkopri difetti fil-materjali u l-abbilità taħt użu u servizz normali.
For warranty claims or to understand the full terms and conditions, please refer to the warranty card included with your product or contact Star Water Systems customer support.
Note: This product is not available for shipment to California.
Appoġġ għall-Klijent
For technical assistance, replacement parts, or warranty inquiries, please contact Star Water Systems customer support.
- Websit: www.starwatersystems.com (Eżampil-link, il-link attwali jista' jvarja)
- Telefon: Refer to your product packaging or the manufacturer's websit għal numri ta' kuntatt attwali.
When contacting support, please have your model number (025191) and date of purchase readily available.





