1. Prodott Aktarview
The EXCEL Tankless Gas Water Heater is designed to provide instant hot water for various applications, including small apartments, lofts, flats, RVs, and mobile homes. This unit operates on Propane (LPG) and features exclusive low water pressure startup technology, requiring only 2 PSI of water pressure to activate. Its vent-free design eliminates the need for complex and costly flue installations, making it a convenient and energy-efficient solution for on-demand hot water.

Figura 1.1: Quddiem u ġenb view of the EXCEL Tankless Gas Water Heater, showcasinid-disinn kompatt u l-pumi tal-kontroll tiegħu.
Karatteristiċi ewlenin:
- Propane Gas (LPG) Unit: Designed for use with liquid propane gas.
- Low Water Pressure Startup: Activates with as little as 2 PSI of water pressure, ideal for areas with fluctuating water supply. This is achieved through a magnetic water flow sensor, unlike older units that rely on rubber diaphragms requiring higher pressure.
- Vent-Free Technology: Does not require a traditional flue or ductwork for exhaust. Equipped with an Oxygen Depletion Safety (ODS) shutoff and an exclusive 20-minute safety shutoff feature for indoor installation with proper ventilation.
- Daqs kompatt: Dimensions are approximately 12.8 inches (front width) x 8 inches (depth) x 18.75 inches (height), allowing for flexible installation.
- Tqabbid Awtomatiku: Powered by 2 D-size batteries (included) for automatic ignition upon water flow.
- Energy and Water Saving: Delivers hot water instantly, reducing waste.
2. Informazzjoni dwar is-Sigurtà
Read and understand all safety warnings and instructions before installing, operating, or performing maintenance on this appliance. Failure to follow these instructions could result in property damage, personal injury, or death.
Prekawzjonijiet Ġenerali tas-Sigurtà:
- Dan l-apparat għandu jiġi installat minn professjonist kwalifikat skont il-kodiċijiet u r-regolamenti lokali kollha.
- Ensure adequate ventilation when installing the unit indoors due to its vent-free design.
- Taħżinx jew tużax gażolina jew fwar u likwidi oħra li jaqbdu fil-viċinanza ta' dan jew kwalunkwe apparat ieħor.
- Check for gas leaks using a soapy water solution after installation and during maintenance. Never use an open flame.
- The unit is equipped with an Oxygen Depletion Safety (ODS) shutoff system and a 20-minute safety shutoff feature. Do not bypass or tamper b'dawn l-apparati tas-sigurtà.
- Ensure proper battery installation for automatic ignition. Use new, high-quality D-size alkaline batteries.
- Protect the unit from freezing temperatures. Drain the unit if it will be exposed to freezing conditions (see Maintenance section).
- Dan il-prodott fih kimiċi magħrufa mill-Istat ta' California li jikkawżaw kanċer u difetti fit-twelid jew ħsara riproduttiva oħra (twissija tal-Propożizzjoni 65).
3. Setup u Installazzjoni
Proper installation is critical for the safe and efficient operation of your EXCEL Tankless Gas Water Heater. Refer to the diagrams below for connection points.
Identifikazzjoni tal-Komponent:

Figure 3.1: Connection points at the bottom of the unit.

Figure 3.2: Location of the Winter Drain and Battery Box.
Passi ta' Installazzjoni:
- Immuntar: Securely mount the unit to a wall using appropriate hardware. Ensure the mounting surface can support the weight of the unit when filled with water.
- Konnessjonijiet tal-Ilma:
- Connect the cold water supply line to the Daħla tal-Ilma Kiesaħ.
- Connect the hot water output line to the Żbokk tal-Ilma sħun.
- Ensure all water connections are tight and leak-free. Use appropriate sealing tape or compound.
- Konnessjoni tal-gass:
- Connect the Propane (LPG) gas supply line to the Dħul tal-gass. The unit includes an LPG Brass Fitting for a ⅜" Flare connection.
- Verify all gas connections are secure and test for leaks using a soapy water solution.
- Installazzjoni tal-batterija: Open the battery box and insert two D-size batteries. Ensure correct polarity. These batteries power the automatic ignition system.
- Ventilazzjoni: For indoor installations, ensure the area has adequate ventilation as this is a vent-free appliance.

Figura 3.3: Intern view highlighting the magnetic water flow sensor, which enables low water pressure startup.
4. Istruzzjonijiet Operattivi
Follow these steps to operate your EXCEL Tankless Gas Water Heater.
Istartjar Inizjali:
- Ensure all water and gas connections are properly made and leak-free.
- Iftaħ il-valv prinċipali tal-provvista tal-gass.
- Open a hot water faucet in your system. The unit will detect water flow (as low as 2 PSI) and automatically ignite.
- Allow water to run for a few moments to purge any air from the lines.
Operazzjoni ta' Kuljum:
- To get hot water, simply open any hot water faucet connected to the unit. The heater will automatically ignite and begin heating water as it flows through.
- The unit is designed for a temperature rise of approximately 45°F, delivering 1.6 Gallons Per Minute (GPM).
- While suitable for multiple points of use, it is recommended to use no more than one point of use at a time for optimal performance.
- For incoming cold water temperatures below 50°F (down to 40°F), you may need to reduce the water flow rate using the control knob to achieve desired hot water temperature.
- The unit features a 20-minute safety shutoff. If hot water is continuously drawn for more than 20 minutes, the unit will automatically shut off. To restart, close the hot water faucet and then reopen it.
5. Manutenzjoni
Manutenzjoni regolari tiżgura l-lonġevità u t-tħaddim effiċjenti tal-water heater tiegħek.
Kontrolli ta' Rutina:
- Sostituzzjoni tal-batterija: Replace the two D-size batteries annually, or if the ignition becomes inconsistent. Use high-quality alkaline batteries.
- Spezzjoni tat-tnixxija: Periodically check all water and gas connections for leaks. For gas leaks, use a soapy water solution.
- Tindif ta' barra: Naddaf il-barra tal-unità b'artab, damp drapp. Tużax tindif jew solventi li joborxu.
Winterization (Freezing Protection):
If the unit will be exposed to freezing temperatures, it is crucial to drain all water from the system to prevent damage.
- Itfi l-provvista tal-gass lill-unità.
- Itfi l-provvista tal-ilma kiesaħ lejn l-unità.
- Open a hot water faucet in your system to relieve pressure.
- Sib il- Winter Drain valve at the bottom of the unit (refer to Figure 3.2). Open this valve to drain the water from the heat exchanger.
- Once drained, close the drain valve.

Figura 5.1: Intern view of the copper heat exchanger, which should be drained to prevent freezing damage.
6 Issolvi l-problemi
This section provides solutions to common issues you might encounter with your water heater.
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| L-ebda ilma sħun / L-unità ma tixgħelx | L-ebda fluss tal-ilma jew pressjoni tal-ilma insuffiċjenti | Ensure water supply is on and water pressure is at least 2 PSI. Check for kinks in water lines. |
| Batteriji mejta jew baxxi | Replace both D-size batteries with new alkaline batteries. | |
| L-ebda provvista tal-gass | Ensure gas tank is not empty and gas supply valve is fully open. | |
| ODS or 20-minute safety shutoff activated | Ensure adequate ventilation. If unit ran for 20 minutes, close and reopen hot water faucet to reset. | |
| L-ilma mhux sħun biżżejjed | High water flow rate for incoming temperature | Reduce water flow rate using the control knob on the unit. |
| Temperatura baxxa tal-ilma li jkun dieħel | The unit adds approximately 45°F to incoming water. If incoming water is very cold, the output temperature will be lower. Reduce flow rate. | |
| Gas or water leaks | Konnessjonijiet sfużi jew komponenti bil-ħsara | Tighten all connections. If leaks persist, contact a qualified professional for inspection and repair. Do not attempt to repair gas leaks yourself. |
Jekk il-problema tippersisti wara li tipprova dawn is-soluzzjonijiet, ikkuntattja tekniku tas-servizz kwalifikat.
7. Speċifikazzjonijiet
Technical specifications for the EXCEL Tankless Gas Water Heater.

Figure 7.1: Product label with detailed specifications.
| Speċifikazzjoni | Valur |
|---|---|
| Brand | EĊĊEL |
| Numru tal-Mudell | 850020757060 |
| Dimensjonijiet tal-Prodott (W x D x H) | 12.8" x 8" x 18.75" (madwar) |
| Piż tal-oġġett | 8.6 liri |
| Tip ta' Fjuwil | Propan (LPG) |
| Voltage | 3 Volts (for ignition) |
| Batteriji Meħtieġa | 2 D-size batteries |
| Rata massima tal-fluss | 1.6 Galluni Kull Minuta (GPM) |
| Output tas-Sħana | 40,000 Unità Termali Brittanika (BTU) |
| Żieda fit-temperatura | Adds approximately 45°F to cold water |
| Minimum Water Pressure Startup | 2 PSI |
| Pressjoni Operattiva Massima | 120 PSI |
| Karatteristiċi tas-Sigurtà | Oxygen Depletion Safety (ODS) shutoff, 20-minute safety shutoff |
| Tip ta 'Immuntar | Mount Wall |
| Komponenti Inklużi | 2 Size D Batteries, Exhaust diffuser Plate, LPG Brass Fitting for ⅜" Flare connection |
8. Garanzija u Appoġġ
For warranty information and technical support, please refer to the documentation included with your purchase or contact the seller directly. The seller for this product is typically Energy-Store.
For additional resources and product information, you may visit the official EXCEL websit: www.excelonlinestore.com





