Introduzzjoni
This manual provides detailed instructions for the installation, operation, and maintenance of your Commercial Electric 6-inch Integrated LED Recessed Downlight with Nightlight Trim. Please read all instructions carefully before installation and retain this manual for future reference.
Informazzjoni dwar is-Sigurtà
- Dejjem itfi l-enerġija mis-circuit breaker qabel tibda l-installazzjoni jew tagħmel xi manutenzjoni.
- Ikkonsulta elettriċista kwalifikat jekk m'intix ċert dwar il-proċess ta 'installazzjoni.
- Kun żgur li l-konnessjonijiet elettriċi kollha jsiru skont il-kodiċijiet u l-ordinanzi lokali.
- Tippruvax timmodifika l-apparat. Kwalunkwe modifika tista' tħassar il-garanzija u toħloq periklu għas-sigurtà.
- This fixture is designed for use with 120V, 60Hz circuits.
- Ilbes nuċċalijiet u ingwanti tas-sigurtà waqt l-installazzjoni.
Karatteristiċi
- Teknoloġija LED integrata: Energy-efficient lighting with a long lifespan.
- Temperatura tal-Kulur Aġġustabbli: Select from 2700K (Warm White), 3000K (Soft White), 3500K (Cool White), 4000K (Bright White), or 5000K (Daylight).
- Modalità Nightlight: Provides a soft amber glow (2000K, 35 Lumens) for ambient illumination.
- Luminożità Għolja: Delivers 670 Lumens of light output using only 11 Watts of power.
- Dimmable: Compatible with most standard LED dimmers (down to 10%).
- Klassifikazzjoni Imxarrba: Adattat għal damp and wet locations, including bathrooms and showers.
- Direct Contact to Insulation: Designed for safe installation in ceilings with insulation.
- Kostruzzjoni Durabbli: Heavy-duty metal construction for long-lasting performance.
- Long Rated Life: Sa 50,000 sigħat ta 'tħaddim.
Speċifikazzjonijiet
| Brand | Kummerċjali elettriċi |
| Numru tal-Mudell | 346798989 |
| Tip ta' Sors tad-Dawl | LED integrat |
| Wattage | 11 Watts |
| Output Lumen | 670 Lumens |
| Temperaturi tal-Kulur | 2700K, 3000K, 3500K, 4000K, 5000K |
| Nightlight Color Temp | 2000K (Ambra Artab) |
| Dimmable | Iva (sa 10%) |
| Wet Rated | Iva |
| Materjal | Copper (internal components), Metal (housing) |
| Ħajja Rated | 50,000 sigħat |
Setup u Installazzjoni
This fixture is designed for easy installation in existing 6-inch recessed housings or new construction/remodeling projects. Ensure power is OFF at the circuit breaker before proceeding.
- Prepare the Recessed Housing: Remove any existing bulb and trim from the recessed can.
- Agħżel it-Temperatura tal-Kulur: Locate the slide switch on the back of the LED downlight fixture. Before installation, select your desired color temperature (2700K, 3000K, 3500K, 4000K, or 5000K). Once installed, this switch is not easily accessible.
- Qabbad l-Adapter: Screw the E26 adapter (standard screw-in base) into the existing bulb socket inside the recessed housing.
- Connect the Fixture: Plug the orange quick connector from the LED downlight into the corresponding connector from the E26 adapter. Ensure a secure connection.

- Insert the Downlight: Gently push the LED downlight into the recessed housing. The spring clips on the sides of the fixture will secure it in place against the ceiling.
- Irrestawra l-Enerġija: Erġa' ixgħel il-kurrent mis-circuit breaker.
Istruzzjonijiet Operattivi
Tibdil tat-Temperatura tal-Kulur
The desired color temperature (2700K, 3000K, 3500K, 4000K, or 5000K) is selected using a slide switch located on the back of the fixture. This selection must be made prior to installation.
Activating Nightlight Mode
To activate the Nightlight mode (2000K Soft Amber glow):
- Kun żgur li d-dawl bħalissa huwa MITFI.
- Quickly toggle your wall switch ON/OFF/ON. The fixture will illuminate in Nightlight mode.
To return to the standard downlight mode from Nightlight mode:
- Quickly toggle your wall switch OFF/ON/OFF. The fixture will return to the previously selected standard color temperature.
Funzjoni Dimming
This LED downlight is dimmable down to 10% with compatible LED dimmer switches. Refer to the product specifications or packaging for a list of recommended dimmer models.
Manutenzjoni
The integrated LED light source does not require bulb replacement. For cleaning, ensure the power is turned OFF at the circuit breaker.
- Imsaħ l-apparat b'ċarruta ratba, niexfa, jew kemxejn imxarrbaamp drapp.
- Do not use abrasive cleaners, solvents, or polishes, as these can damage the finish or electrical components.
- Kun żgur li l-apparat ikun niexef għalkollox qabel ma terġa' ddaħħal il-kurrent.
Issolvi l-problemi
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Id-dawl ma jixgħelx | No power to the fixture; Loose connection; Faulty switch. | Check circuit breaker; Ensure all connections are secure; Test wall switch. |
| Light flickers or dims improperly | Swiċċ tad-dimmer inkompatibbli; Wajers maħlula. | Ensure dimmer is LED compatible; Check wiring connections. |
| Nightlight mode does not activate | Incorrect wall switch toggling sequence. | Follow the ON/OFF/ON sequence precisely. |
| Light is not the desired color temperature | Slide switch set incorrectly. | Remove fixture and adjust the slide switch on the back. |
Informazzjoni dwar Garanzija
Specific warranty details for this product are not provided in the available information. Please refer to the product packaging or contact Commercial Electric customer support for warranty terms and conditions.
Appoġġ
For technical assistance or further inquiries, please refer to the contact information provided on the product packaging or the official Commercial Electric website. Please have your model number (346798989) available when contacting support.