APEX Domus 3

Manwal tal-Utent tas-Sistema ta' Saqqijiet bi Pressjoni Alternanti Apex Medical Domus 3

Model: Domus 3

1. Introduzzjoni

This manual provides comprehensive instructions for the safe and effective use of the Apex Medical Domus 3 Alternating Pressure Mattress System. This system is designed to assist in the prevention and treatment of pressure injuries, ulcers, and bedsores for individuals requiring extended bed rest. Please read this manual thoroughly before setup and operation.

Apex Medical Domus 3 Alternating Pressure Mattress System with pump on a hospital bed.

Figura 1.1: The Apex Medical Domus 3 Alternating Pressure Mattress System. This image displays the complete system, including the mattress installed on a hospital bed frame and the external pump unit. The mattress features individual air cells, and the pump is shown connected to the mattress.

2. Informazzjoni dwar is-Sigurtà

Adherence to the following safety guidelines is crucial for patient well-being and proper system function.

3. Komponenti

The Apex Medical Domus 3 system typically includes the following components:

4. Istruzzjonijiet ta' Setup

  1. Ipprepara l-Qafas tas-Sodda: Place the mattress system directly onto a standard hospital or home bed frame. Ensure the bed frame is clean and free of sharp objects that could damage the mattress.
  2. Pożizzjona s-Saqqu: Unroll the Domus 3 mattress on the bed frame with the air hose connection end positioned towards the foot of the bed where the pump will be placed. Ensure the CPR strap is accessible.
  3. Qabbad il-Pompa: Attach the air hoses from the mattress to the corresponding connectors on the variable pressure pump unit. Ensure connections are secure.
  4. Immuntar il-Pompa: Hang the pump unit securely at the foot of the bed using its integrated hangers.
  5. Qabbad l-Enerġija: Plug the pump's power cord into a grounded electrical outlet.
  6. Inflazzjoni Inizjali: Turn on the pump. The mattress will begin to inflate. Allow approximately 20-30 minutes for the mattress to fully inflate and stabilize before placing a patient on it.
Apex Medical Domus 3 mattress cover with zipper and water-resistant material detail.

Figura 4.1: Mattress Cover Features. An image showcasing two features of the mattress cover: a close-up of the zipper-all-around design for easy removal and replacement, and a magnified view of the Nylon/PU cover material demonstrating its water-resistant properties with water droplets on the surface.

5. Istruzzjonijiet Operattivi

5.1 Power On/Off

5.2 Modi ta' Terapija

The Domus 3 offers two therapy modes:

Refer to the pump unit's controls to select the desired therapy mode.

Diagram illustrating the alternating pressure redistribution cycle of the mattress.

Figura 5.1: Alternating Pressure Cycle. This diagram shows a human figure lying on the mattress, with an illustration of the alternating pressure cycle. Blue blocks represent inflated air cells, and arrows indicate the cyclical inflation and deflation pattern designed to redistribute pressure and prevent injury.

5.3 Pressure Adjustment (Firmness)

The pump unit features a variable pressure setting with a weight indicator.

5.4 Low Air Loss Function

Air cells 3 through 11 are designed with a low air loss feature. This function continuously ventilates air to wick moisture and heat away from the mattress surface, contributing to patient comfort and skin integrity. This operates automatically when the system is powered on.

Close-up of Apex Medical Domus 3 mattress showing low air loss ventilation.

Figura 5.2: Low Air Loss Feature. A detailed view of the mattress surface, highlighting the low air loss feature. Blue arrows indicate airflow through the air cells, designed to reduce moisture and heat for patient comfort and prevent skin maceration.

6. Manutenzjoni u Kura

6.1 Cleaning the Mattress and Cover

6.2 Air Cell Replacement

Each of the 20 individual 8-inch air cells can be removed and replaced if damaged.

  1. Turn off the pump and disconnect it from the mattress.
  2. Unzip the mattress cover.
  3. Carefully detach the damaged air cell from its connections within the mattress structure.
  4. Install a new, compatible air cell, ensuring it is securely connected.
  5. Zip the mattress cover back into place and re-connect the pump for inflation.

7 Issolvi l-problemi

ProblemaKawża PossibbliSoluzzjoni
Mattress not inflating or losing pressure
  • Korda tal-enerġija skonnettjata
  • Air hoses not securely connected
  • Leak in mattress or air cells
  • Malfunzjoni tal-pompa
  • Check power connection to outlet and pump.
  • Ensure air hoses are firmly attached to both mattress and pump.
  • Inspect mattress and individual air cells for punctures or damage. Replace damaged cells if necessary.
  • Contact customer support if pump appears to be malfunctioning.
Low pressure alarm sounds
  • Mattress not fully inflated
  • Tnixxija tal-arja
  • Patient weight exceeds capacity
  • Allow more time for inflation.
  • Check for leaks in mattress or hose connections.
  • Verify patient weight is within the 440 lbs capacity.
Pump is unusually loud
  • Obstruction around pump fan
  • Malfunzjoni tal-pompa
  • Ensure adequate ventilation around the pump unit.
  • Contact customer support if noise persists. (Note: Pump noise level is typically ≤ 30dB(A)).

8. Speċifikazzjonijiet

KaratteristikaDettall
MudellDomus 3
Mattress Dimensions (L x W x H)78.7 x 35.4 x 8 pulzieri
Piż tas-SistemaMadwar 22.3-il Lira
Kapaċità tal-piż440 liri
Tip tad-drappNylon, Polyurethane (Cover)
Karatteristiċi SpeċjaliLow Air Loss, Alternating Pressure, Water Resistant Cover, CPR Strap, Low Pressure Alarm
Livell tal-Istorbju tal-Pompa≤ 30dB (A)
ManifatturApex Mediku
Dimensions of Apex Medical Domus 3 mattress and pump system.

Figura 8.1: System Dimensions. A visual representation of the dimensions for both the Apex Medical Domus 3 mattress and its accompanying pump unit. Key measurements for length, width, and height are indicated for both components.

Apex Medical Domus mattress showing two height options, 5-inch and 8-inch.

Figura 8.2: Mattress Height Options. This image illustrates the two available height options for the Domus mattress: a 5-inch version and an 8-inch version. The current product is the 8-inch model, providing enhanced support.

9. Garanzija u Appoġġ

9.1 Informazzjoni dwar Garanzija

The Apex Medical Domus 3 Alternating Pressure Mattress System comes with a Garanzija ta' 1 snin on both the mattress and the pump unit. This warranty covers manufacturing defects and malfunctions under normal use. Please retain your proof of purchase for warranty claims.

9.2 Appoġġ għall-Klijent

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Apex Medical customer support. Refer to the product packaging or the official Apex Medical websit għal informazzjoni ta' kuntatt attwali.

Dokumenti Relatati - Domus 3

Preview Gwida Rapida għall-Modalità tal-Fornitur Awtomatiku tal-APEX XT
Gwida rapida għall-professjonisti mediċi dwar kif jużaw l-apparat APEX XT Auto fil-Modalità Fornitur, inkluż is-setup tan-navigazzjoni u r-risettjar tal-miters tal-konformità.
Preview Manwal tal-Utent tal-Pompa APEX VAC: Istruzzjonijiet u Gwida tas-Sigurtà
Manwal komprensiv għall-utent għall-Pompa APEX VAC, li jiddeskrivi l-operazzjoni, is-sigurtà, l-ispeċifikazzjonijiet tekniċi, u s-soluzzjoni tal-problemi għall-mudelli VacPro, VacMaxi, u VacPlus minn Apex Medical Corp.
Preview Manwal tal-Istruzzjonijiet tas-Sistema APEX XT Auto CPAP
Manwal ta' struzzjonijiet komprensiv għas-Sistema APEX XT Auto CPAP (Mudell 9S-005720), li jagħti dettalji dwar is-setup, it-tħaddim, il-manutenzjoni, is-soluzzjoni tal-problemi, u l-ispeċifikazzjonijiet tekniċi għat-trattament tal-Apnea Ostruttiva tal-Irqad (OSA).
Preview Manwal tal-Istruzzjonijiet tas-Siġġu tal-Massaġġi APEX-V2 - Gwida għat-Twaqqif, it-Tħaddim, u l-Manutenzjoni
Comprehensive instruction manual for the APEX-V2 massage chair, covering safety precautions, installation, operation, settings, specifications, troubleshooting, cleaning, and maintenance. Learn how to set up and use your APEX-V2 massage chair effectively.
Preview Manwal tas-Sid tas-Sistema ta' Sigurtà DESTINY
Dan il-manwal tas-sid għas-Sistema ta' Sigurtà Apex DESTINY jipprovdi gwida komprensiva dwar l-installazzjoni, it-tħaddim, il-modi ta' armar (AWAY, HOME, NIGHT), aċċess remot, funzjonijiet ta' bypass, u karatteristiċi fakultattivi ta' awtomazzjoni tad-dar.
Preview Manwal tal-Utent tas-Siġġu tal-Massaġġi Apex AP-Pomp
Manwal komprensiv tat-tħaddim tal-utent għas-siġġu tal-massaġġi Apex AP-Pomp, li jkopri l-prekawzjonijiet ta' sigurtà, il-manutenzjoni, l-installazzjoni, il-funzjonijiet tal-kontrollur, is-soluzzjoni tal-problemi, u l-ispeċifikazzjonijiet.