OJ Electronics UDG4-4999-B

Manwal tal-Utent tat-Termostat OJ Microline UDG4-4999

Programmable Thermostat for Radiant Floor Heating Systems

1. Introduzzjoni

This manual provides detailed instructions for the installation, operation, and maintenance of your OJ Microline UDG4-4999 Touch Screen Programmable Thermostat. Designed for electric radiant floor heating systems, this thermostat features dual voltage (120V/240V) and dual sensing (air/floor) capabilities, along with a built-in Class A GFCI for enhanced safety. Please read this manual thoroughly before installation and use to ensure proper function and safety.

OJ Microline UDG4-4999 Thermostat front view

Figura 1: Quddiem view of the OJ Microline UDG4-4999 Thermostat, displaying its intuitive touch screen interface.

2. Informazzjoni dwar is-Sigurtà

TWISSIJA: Risk of electric shock. Installation must be performed by a qualified electrician in accordance with local electrical codes. Disconnect power at the circuit breaker before installing or servicing the thermostat.

3. Setup u Installazzjoni

The UDG4-4999 thermostat is designed for easy installation in a standard electrical box. It supports both 120V and 240V systems and includes a floor sensor for precise temperature control.

3.1 Tneħħija tal-kaxxa u l-komponenti

Carefully remove the thermostat and its components from the packaging. The package should include:

3.2 Istruzzjonijiet tal-Wiring

Follow the wiring diagram below for correct installation. Ensure all connections are secure and comply with local electrical codes. The thermostat requires a dedicated circuit.

Wiring diagram for OJ Microline UDG4-4999 Thermostat

Figure 2: Technical specifications and wiring diagram for the UDG4-4999 Thermostat. Note the connections for Neutral, Hot from power source, and House Ground.

  1. Itfi l-enerġija mill-circuit breaker prinċipali.
  2. Connect the power supply wires (Line/Load) to the appropriate terminals on the thermostat as indicated in the wiring diagram.
  3. Connect the floor heating cable wires to the designated heating load terminals.
  4. Connect the floor sensor wires to the sensor terminals. Ensure the sensor is properly placed in the floor according to heating system manufacturer guidelines.
  5. Waħħal it-termostat mal-kaxxa elettrika bl-użu tal-viti pprovduti.
  6. Irrestawra l-enerġija fis-circuit breaker.

4. Istruzzjonijiet Operattivi

The UDG4-4999 thermostat features an intuitive 3.5" responsive touch color screen for easy operation and programming.

4.1 Initial Setup and Install Wizard

Upon first power-up, the thermostat will guide you through an Install Wizard to set basic parameters such as date, time, temperature units, and floor type.

4.2 Aġġustament Bażiku tat-Temperatura

From the main screen, you can easily adjust the setpoint temperature using the up and down arrows. The thermostat will temporarily override any active program until the next scheduled event.

Hand adjusting temperature on thermostat screen

Figure 3: A hand interacting with the thermostat screen to adjust the temperature setpoint.

4.3 Programming the Thermostat

The thermostat offers a 7-day programmable schedule with multiple events per day to optimize comfort and energy savings. Access the programming menu via the main screen's menu button.

4.4 Karatteristiċi Avvanzati

5. Manutenzjoni

The OJ Microline UDG4-4999 thermostat requires minimal maintenance.

6 Issolvi l-problemi

Jekk tesperjenza problemi bit-termostat tiegħek, irreferi għall-problemi u s-soluzzjonijiet komuni li ġejjin:

ProblemaKawża PossibbliSoluzzjoni
L-iskrin tat-termostat huwa vojt.No power, tripped circuit breaker, or loose wiring.Check circuit breaker. Ensure wiring connections are secure. Contact a qualified electrician if problem persists.
Is-sistema tat-tisħin mhux qed tixgħel.GFCI tripped, thermostat in OFF mode, or wiring issue.Press the GFCI 'Reset' button. Check thermostat mode. Verify wiring.
Temperatura mhux preċiża.Floor sensor issue or improper placement.Ensure floor sensor is correctly installed and not damaged.
Cannot turn the thermostat completely OFF for summer.Thermostat may not have a dedicated 'OFF' button for the heating function, or it's in a continuous program mode.Set the thermostat to Vacation Mode with a very low setpoint, or use the 'OFF' setting if available in the menu. For complete power disconnection, turn off the dedicated circuit breaker.

7. Speċifikazzjonijiet

KaratteristikaDettall
Numru tal-MudellUDG4-4999-B
Voltage120V / 240V AC
Tagħbija Massima15 Amps (1800W@120V, 3600W@240V)
GFCIClass A (5mA trip level)
Tip ta' Kontroll tat-TemperaturaTisħin fl-art
TiskopriDual Sensing (Air & Floor)
Floor Limit Range+41 sa +104°F (+5 sa +40°C)
Firxa tat-Temperatura Ambjentali+32 sa +104°F (0 sa +40°C)
Tip ta 'Wiri3.5 Pulzier Touchscreen
Teknoloġija tal-KonnettivitàBil-fili
Tip ta 'ImmuntarMount Wall
ĊertifikazzjonijietC-UL-us Listed, Certified for Wet Room installations
DimensjonijietAppross. 6 x 3.5 x 2.6 pulzieri
Piż tal-oġġett12.8 uqija

8. Garanzija u Appoġġ

8.1 Limited Factory Warranty

The OJ Microline UDG4-4999 Thermostat comes with a 3-Year limited factory WarrantyDin il-garanzija tkopri difetti fil-materjali u fix-xogħol taħt użu normali. Jekk jogħġbok żomm il-prova tax-xiri tiegħek għal talbiet ta' garanzija.

8.2 Appoġġ għall-Klijent

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact OJ Electronics customer support. Refer to the official OJ Electronics webis-sit għall-aktar informazzjoni ta' kuntatt aġġornata.

Dokumenti Relatati - UDG4-4999-B

Preview Termostat OJ Microline UTN4-4999 għal Tisħin Elettriku taħt l-Art | OJ Electronics
Esplora l-OJ Microline UTN4-4999, termostat eleganti u intuwittiv għat-tisħin elettriku taħt l-art. Il-karatteristiċi jinkludu reġistrazzjoni tal-enerġija, protezzjoni tal-art, GFCI, u speċifikazzjonijiet tekniċi dettaljati. Ideali għal installazzjonijiet residenzjali.
Preview Manwal tal-Utent u Gwida għall-Installazzjoni tat-Termostat OJ Electronics UDG/UDG/UTN/USG
Gwida għall-utent u l-installazzjoni għat-termostati OJ Electronics UDG, UDG, UTN, USG. Tkopri l-installazzjoni, il-programmazzjoni, it-tħaddim, is-sigurtà GFCI, u s-soluzzjoni tal-problemi għal sistemi ta' tisħin elettriku taħt l-art.
Preview UWG5 WiFi LED Touch Thermostat User Manual - OJ Electronics
Comprehensive user manual for the OJ Electronics UWG5 WiFi LED Touch Thermostat. Learn about setup, features, smart home integration with Alexa and Google, troubleshooting, and more.
Preview Istruzzjonijiet tat-Termostat Diġitali OJ Electronics MCD3-1999-UAE6
Manwal tal-utent u gwida għall-installazzjoni għat-termostat diġitali OJ Electronics MCD3-1999-UAE6, li jkopri s-setup, it-tħaddim, is-sigurtà, u l-ispeċifikazzjonijiet tekniċi għat-tisħin elettriku taħt l-art.
Preview OJ Electronics UWG4/AWG4 WiFi Touch Thermostat Quick Start Guide
Quick start guide for the OJ Electronics UWG4/AWG4 WiFi Touch Thermostat, covering installation, setup, and basic operation for underfloor heating systems.
Preview Manwal tal-Utent tat-Termostat Touch UTN5 ta' OJ Electronics
Manwal komprensiv għall-utent għat-Termostat Touch UTN5 ta' OJ Electronics, li jiddeskrivi l-karatteristiċi tiegħu, il-wizard tas-setup, is-settings operattivi, u gwida għas-soluzzjoni tal-problemi.