SKINACT Sage Electric Spa Treatment Table

SKINACT Sage Electric Spa Treatment Table User Manual

Model: Sage Electric Spa Treatment Table

Introduzzjoni

Thank you for choosing the SKINACT Sage Electric Spa Treatment Table. This manual provides essential information for the safe and efficient use, setup, operation, and maintenance of your new electric spa table. Please read this manual thoroughly before initial use and retain it for future reference.

SKINACT Sage Electric Spa Treatment Table, front-side view

Image: The SKINACT Sage Electric Spa Treatment Table in white upholstery with a natural wood finish base, shown from a front-side angle.

Informazzjoni dwar is-Sigurtà

Adherence to the following safety guidelines is crucial for preventing injury and damage to the equipment:

  • Always use the remote control to adjust the table's position slowly and carefully to prevent tipping.
  • Keep the face-hole area clear of obstructions when the client is in the face-down position.
  • Teċċedix il-kapaċità massima tal-piż ta' 330 lbs (150 kg).
  • Keep the table away from heat sources and sharp objects to prevent damage to the upholstery and potential injury.
  • Ensure the power cord is not pinched or damaged. Do not operate the table if the power cord is compromised.
  • Unplug the table from the power outlet before cleaning or performing any maintenance.

Setup

The SKINACT Sage Electric Spa Treatment Table is shipped fully assembled, simplifying the setup process.

Spakkjar u Tqegħid

  1. Carefully remove all packaging materials. Inspect the table for any signs of damage incurred during shipping. Report any damage to the carrier and SKINACT customer service immediately.
  2. Position the table on a flat, stable, and level surface. Ensure there is adequate space around the table for safe operation and client access.
  3. Locate a grounded electrical outlet within reach of the power cord. Avoid using extension cords if possible. If an extension cord is necessary, ensure it is rated for the table's power requirements.

Konnessjoni tal-Enerġija

  1. Plug the power cord securely into the grounded electrical outlet.
  2. The table is now ready for operation.
Diagram showing dimensions of the SKINACT Sage Electric Spa Treatment Table

Image: A diagram illustrating the dimensions of the spa table, including length, width, height range, and maximum weight capacity of 330 lbs.

Istruzzjonijiet Operattivi

The SKINACT Sage Electric Spa Treatment Table features three motors for adjusting height, backrest, and central module inclination, all controlled via a wired remote.

Funzjonijiet ta 'Kontroll mill-bogħod

The remote control allows for precise adjustments to optimize client comfort and practitioner ergonomics.

Close-up of the SKINACT electric spa table remote control

Immaġni: Close-up view of the wired remote control, showing buttons for height adjustment, backrest adjustment, central module adjustment, lock, power, reset, lamp, and heating functions.

  • Aġġustament Għoli: Use the dedicated buttons to raise or lower the entire table. The adjustable height range is 23 inches to 37 inches.
  • Graphic illustrating height adjustment of the spa table

    Image: A graphic depicting the spa table's height being adjusted up and down, indicated by green arrows.

  • Aġġustament tad-dahar: Control the inclination of the backrest from 0° (flat) to +70° (upright position).
  • Graphic illustrating backrest adjustment of the spa table

    Image: A graphic showing the backrest of the spa table inclining upwards, indicated by a green arrow.

  • Central Module Inclination: Adjust the central section of the table from 0° to +28° for various treatment positions.
  • Graphic illustrating central module adjustment of the spa table

    Image: A graphic showing the central module of the spa table inclining upwards, indicated by a green arrow.

  • Funzjoni Lock: Press the 'LOCK' button to prevent accidental adjustments. Press again to unlock.
  • Buttuna tal-Qawwa: Turns the table's electrical functions on or off.
  • Buttuna Irrisettja: Resets the table to a default flat position.
  • Lamp Buttuna: Activates or deactivates any integrated lighting (if applicable).
  • Buttuna tat-Tisħin: Activates or deactivates the heating function (if applicable).

Detentur tax-Xugamani

The table includes a convenient towel holder located on the side of the base.

Close-up of the integrated towel holder on the spa table

Immaġni: Close-up view of the white metal towel holder extending from the wooden base of the spa table.

Manutenzjoni

Proper maintenance ensures the longevity and hygienic condition of your spa treatment table.

Tindif tal-Tapizzerija

  • The table features high-quality, easy-cleaning PU upholstery.
  • For general cleaning, wipe the upholstery with a dry cloth.
  • For deeper cleaning or disinfection, use a mild, non-abrasive cleaner specifically designed for PU materials. Test any cleaning solution on an inconspicuous area first.
  • Avoid harsh chemicals, solvents, or abrasive cleaning tools, as these can damage the upholstery.
  • Ensure the table is completely dry before next use.

Kura Ġenerali

  • Regularly inspect all moving parts and electrical connections for wear or damage.
  • Keep the area around the motors and moving mechanisms free from dust and debris.
  • Do not place heavy or sharp objects on the table when not in use.

Issolvi l-problemi

If you encounter issues with your SKINACT Sage Electric Spa Treatment Table, refer to the following common troubleshooting steps:

ProblemaKawża PossibbliSoluzzjoni
Table does not respond to remote control.No power, remote control cable disconnected, or remote control locked.Check if the power cord is securely plugged into a live outlet. Ensure the remote control cable is firmly connected to the table. Press the 'LOCK' button on the remote to unlock it.
Motors make unusual noise.Obstruction in moving parts or motor issue.Inspect for any obstructions under the table or near moving components. If the noise persists, discontinue use and contact customer support.
Table movement is jerky or inconsistent.Power supply issue or motor malfunction.Ensure the power supply is stable. Try resetting the table using the 'RESET' button. If the problem continues, contact customer support.

If these steps do not resolve the issue, please contact SKINACT customer support for further assistance.

Speċifikazzjonijiet

KaratteristikaDettall
MudellSage Electric Spa Treatment Table
BrandSKINACT
Materjal tal-TapizzerijaPU upholstery
Ħxuna tal-Kuxxin4 pulzieri
Base FinishInjam naturali
Muturi3 (for height, backrest, central module)
Medda ta' Għoli Aġġustabbli23" - 37"
Backrest Inclination0° sa +70°
Central Section Inclination0° sa +28°
Dimensjonijiet tal-Prodott (L x W x H)79.5" x 31" x 23"-37" (approx. 80 x 31 x 23 inches)
Piż tal-oġġett200 lbs (90.7 kg)
Maximum Client Weight330 lbs (150 kg)
AssembleaImmuntata kompletament
Kura tal-ProdottImsaħ b'Ċarruta Niexfa

Garanzija u Appoġġ

Informazzjoni dwar Garanzija

Specific warranty details for the SKINACT Sage Electric Spa Treatment Table are typically provided at the time of purchase or can be obtained directly from the manufacturer. Please retain your proof of purchase for warranty claims.

Appoġġ għall-Klijent

For technical assistance, parts, or warranty inquiries, please contact SKINACT customer service:

  • Visit the official SKINACT store on Amazon: SKINACT Store
  • Refer to the contact information provided with your purchase documentation.

Dokumenti Relatati - Sage Electric Spa Treatment Table

Preview Informazzjoni dwar is-Sigurtà tal-Imwejjed tat-Trattament li Jduru SkinAct
Linji gwida essenzjali dwar is-sigurtà għat-tħaddim ta' sodod tal-wiċċ u mwejjed tat-trattament idrawliċi u elettriċi li jduru SkinAct, b'fokus fuq l-istabbiltà u s-sigurtà tal-klijent.
Preview Manwal tal-Utent tal-Mejda tat-Trattament Elettrika Bellage - SkinAct
Manwal tal-utent għall-Mejda tat-Trattament (Siġġu) SkinAct Bellage Kompletament Elettrika b'4 Muturi, li jipprovdi struzzjonijiet, twissijiet, speċifikazzjonijiet, gwida għall-installazzjoni, użu tal-kontrollur, aġġustamenti, u informazzjoni dwar il-manutenzjoni.
Preview Gwida għall-Utent tas-Sistema tal-Kura tal-Ġilda Pro 11 Function
Gwida għall-utent għas-Sistema tal-Kura tal-Ġilda Pro 11 Function (SKU16147) minn SkinAct, li tiddeskrivi d-diversi funzjonijiet tagħha, il-benefiċċji, il-passi operattivi, u l-prekawzjonijiet għall-użu estetiku professjonali.
Preview Manwal tal-Utent u Gwida tal-Immuntar tas-Siġġu SkinAct Lusso IV
Manwal komprensiv għall-utent u struzzjonijiet għall-assemblaġġ għas-siġġu recliner elettriku SkinAct Lusso IV. Tgħallem kif tiġbor, tħaddem, u żżomm is-siġġu Lusso IV tiegħek.
Preview SkinAct Roll On Wax Warmer b'Mankijiet b'Żewġ jew Tliet Slots - Manwal tal-Utent
Manwal uffiċjali għall-utent għall-SkinAct Roll On Wax Warmer (SKU17584), li jipprovdi struzzjonijiet għall-użu, manutenzjoni, twissijiet ta' sigurtà, u speċifikazzjonijiet tekniċi għat-tneħħija tax-xagħar professjonali u personali.
Preview Manwal u Gwida għall-Utent tal-Kopula tat-Terapija bid-Dawl LED ARC SkinAct (SKU25538)
Dan id-dokument jipprovdi struzzjonijiet komprensivi, linji gwida dwar is-sigurtà, proċeduri ta' manutenzjoni, u speċifikazzjonijiet tekniċi għall-SkinAct ARC LED Light Therapy Dome (SKU25538), apparat professjonali tas-sbuħija.