1. Introduzzjoni
This manual provides instructions for the safe and effective operation of the Mastech MS6590P Non-Contact Infrared Digital Thermometer. This device is designed for measuring human body temperature without physical contact, offering a quick and hygienic method for temperature assessment. Please read this manual thoroughly before use and retain it for future reference.
2. Informazzjoni dwar is-Sigurtà
- Tgħaddix l-apparat fl-ilma jew likwidi oħra.
- Keep the device away from direct sunlight, dust, and extreme temperatures.
- Evita li twaqqa 'l-apparat jew suġġett għal impatti qawwija.
- Tippruvax tiżżarma jew issewwi l-apparat int stess. Ikkuntattja persunal tas-servizz kwalifikat.
- Ensure the measurement distance is within 5-15 cm for accurate readings.
- This device is intended for human body temperature measurement. Do not use it for other purposes.
- Żomm fejn ma jintlaħaqx mit-tfal.
3. Prodott Aktarview
The Mastech MS6590P is a handheld, non-contact infrared thermometer featuring a clear LCD display and intuitive controls.

Figura 1: Quddiem view of the Mastech MS6590P thermometer, showing the display, measurement trigger, and function buttons.

Figure 2: Mastech MS6590P thermometer highlighting key features such as precision, fast response, person capacity, temperature conversion, body temperature range, and non-contact measurement.
3.1 Komponenti
- Sensor infra-aħmar: For non-contact temperature measurement.
- Display LCD: Shows temperature readings, mode, and other indicators.
- Measurement Trigger: Activates the measurement process.
- Buttuna tal-Modalità (M): To switch between different measurement modes (e.g., Body/Surface).
- Memory Button (MEM): To access stored temperature readings.
- Buttuna Backlight: To turn the display backlight on/off.
- Kompartiment tal-batterija: Located at the handle for battery installation.
4. Setup
4.1 Installazzjoni tal-batterija
- Locate the battery compartment cover on the handle of the thermometer.
- Slide or open the cover according to the indicator.
- Insert one 9V battery, ensuring correct polarity (+/-). (Battery not included)
- Agħlaq l-għatu tal-kompartiment tal-batterija sew.
The device will typically power on automatically or can be turned on by pressing the measurement trigger.
5. Istruzzjonijiet Operattivi
5.1 Taking a Temperature Reading
- Ensure the thermometer is in "Body" mode for human temperature measurement. If not, press the "M" (Mode) button to switch.
- Point the infrared sensor towards the forehead of the person, maintaining a distance of 5-15 cm.
- Press and hold the measurement trigger. The device will scan and display the temperature within 1 second.
- Release the trigger to hold the reading on the display. The reading will automatically be stored in memory.
5.2 Funzjoni tal-Memorja
The MS6590P can store up to 20 temperature readings.
- Biex view stored readings, press the "MEM" button.
- Each press of the "MEM" button will cycle through the stored readings.
5.3 Unit Conversion (Celsius/Fahrenheit)
Refer to the device's specific instructions for changing between Celsius (ºC) and Fahrenheit (ºF), usually involving a combination of button presses or a switch within the battery compartment.
5.4 Tfigħ Awtomatiku
To conserve battery life, the thermometer will automatically shut down after a period of inactivity.
6. Manutenzjoni
6.1 Tindif
- Use a soft, dry cloth to clean the device's exterior.
- For stubborn stains, a cloth lightly dampened bl-alkoħol jistgħu jintużaw.
- Tużax prodotti tat-tindif li joborxu jew tgħaddasx l-apparat fl-ilma.
- Ensure the infrared sensor lens is clean and free of debris for accurate readings.
6.2 Ħażna
- Aħżen it-termometru f'post frisk u niexef, 'il bogħod mix-xemx diretta u minn temperaturi estremi.
- If the device will not be used for an extended period, remove the battery to prevent leakage.
7 Issolvi l-problemi
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| L-apparat ma jixgħelx. | Il-batterija hija mejta jew installata ħażin. | Replace the 9V battery or ensure correct polarity. |
| Qari mhux preċiż. | Sensor lens is dirty; incorrect measurement distance; extreme ambient temperature. | Clean the sensor lens; ensure 5-15 cm distance; use in stable room temperature. |
| Jintwera "Lo" jew "Hi". | Temperature is outside the measurable range (32ºC-42ºC for body). | Ensure the target temperature is within the specified range. |
8. Speċifikazzjonijiet
| Karatteristika | Dettall |
|---|---|
| Brand | Mastech |
| Mudell | MS6590P |
| Firxa tal-Kejl (Ġisem) | 32ºC - 42ºC |
| Eżattezza | ± 0.2 ºC |
| Distanza tal-Kejl | 5 - 15 ċm |
| Ħin ta' Rispons | 1 sekonda |
| Ħażna tal-Memorja | Sa 20 qari |
| Provvista tal-Enerġija | Batterija waħda ta' 9V (mhux inkluża) |
| Tip ta 'Wiri | LCD |
| Materjal | Plastik |
| Ċertifikazzjonijiet | CE, RoHS, ETL, FCC |

Figure 3: Dimensions of the Mastech MS6590P thermometer, showing measurements of 92mm width, 142mm height, and 47mm depth.
9. Garanzija u Appoġġ
Mastech products are manufactured to high-quality standards. For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or visit the official Mastech websit. Jekk jogħġbok żomm il-prova tax-xiri tiegħek għal talbiet ta' garanzija.