1. Introduzzjoni
This manual provides detailed instructions for the installation, operation, and maintenance of the Sure-Lites EBP500 1-Lamp Emergency Battery Pack. This unit is designed to provide emergency power to fluorescent lamps in the event of a power failure, ensuring illumination for safety and egress.
Jekk jogħġbok aqra dan il-manwal bir-reqqa qabel l-installazzjoni u l-użu biex tiżgura l-funzjonament xieraq u s-sigurtà.
2. Istruzzjonijiet Importanti dwar is-Sigurtà
Meta tuża tagħmir elettriku, għandhom dejjem jiġu segwiti prekawzjonijiet bażiċi tas-sigurtà, inklużi dawn li ġejjin:
- TWISSIJA: Biex tevita vol għolitage from being present on output leads prior to installation, do not connect battery connector until installation is complete and AC power is supplied to the unit.
- ATTENZJONI: This unit requires an unswitched AC power source (120/277V AC, 60Hz). Ensure proper voltage huwa fornut.
- ATTENZJONI: For use in UL Listed indoor fixtures only. Do not use outdoors or in hazardous locations.
- ATTENZJONI: This is a sealed, unitized battery. Replace entire unit when necessary.
- Is-servizz kollu għandu jsir minn persunal tas-servizz kwalifikat.
- Twaħħalx ħdejn ħiters tal-gass jew elettriċi.
- It-tagħmir għandu jiġi mmuntat f'postijiet u f'għoli fejn mhux se jkun suġġett għal tampminn persunal mhux awtorizzat.
- L-użu ta 'tagħmir aċċessorju mhux rakkomandat mill-manifattur jista' jikkawża kundizzjoni mhux sigura.
- Tużax dan it-tagħmir għal użu ieħor minbarra l-użu maħsub tiegħu.
3. Komponenti tal-Prodott
The Sure-Lites EBP500 Emergency Battery Pack is a compact unit designed for integration into fluorescent lighting fixtures. Below is an image illustrating the key features of the device.

Figura 1: Sure-Lites EBP500 Emergency Battery Pack. This image shows the elongated, rectangular battery pack with a metal casing. Visible labels include "EBP500 EMERGENCY BATTERY PACK", "120/240/277 VAC", "60Hz", "34W", "260mA", and a "UL LISTED" certification mark. Wiring terminals with color-coded connections (yellow, blue, red, black, white) are clearly visible at one end, along with a small connector for the test switch/indicator light.
Il-komponenti ewlenin jinkludu:
- Pakkett tal-batterija: Sealed Ni-Cad battery system.
- Terminali tal-Wiring: Color-coded for easy connection to the fixture's ballast and lamp.
- Test Switch/Indicator Light Connector: For connecting the remote test switch and charge indicator light.
- Input Voltage: Supports 120/240/277 VAC, 60Hz.
4. Setup u Installazzjoni
Installation should only be performed by a qualified electrician in accordance with the National Electrical Code and local regulations.
4.1 Kontrolli ta' qabel l-installazzjoni
- Ensure AC power to the fixture is turned OFF at the circuit breaker.
- Verify that the fixture is suitable for emergency lighting applications and has adequate space for the EBP500 unit.
- Ikkonferma l-input voltage of the fixture matches the EBP500 (120/240/277 VAC).
4.2 Istruzzjonijiet tal-Wiring
Refer to the wiring diagram provided with your fixture and the EBP500 unit for specific connections. General steps include:
- Mount the EBP500 unit securely within the fixture or in an adjacent accessible location.
- Disconnect the normal AC ballast from the lamp(s) as per the wiring diagram.
- Connect the EBP500's input wires to the unswitched AC power source (Line and Neutral).
- Connect the EBP500's output wires to the lamp(s) according to the diagram, ensuring proper polarity.
- Connect the remote test switch and indicator light to the designated connector on the EBP500. Mount the test switch/indicator light in an accessible location on the fixture.
- Once all wiring is complete, connect the battery connector to the EBP500 unit.
4.3 Iċċarġjar inizjali
After installation, restore AC power to the fixture. The EBP500 requires a minimum of 24 hours of continuous AC power to fully charge the battery before it can provide its rated emergency duration.
5. Istruzzjonijiet Operattivi
5.1 Operazzjoni Normali
When AC power is present, the EBP500 unit is in standby mode, continuously charging its battery. The indicator light (if installed) will be illuminated, signifying that the battery is charging and ready for emergency operation.
5.2 Operazzjoni ta' Emerġenza
Upon interruption of normal AC power, the EBP500 automatically switches to emergency mode, providing power to the connected fluorescent lamp(s) for a minimum of 90 minutes. The indicator light will turn off during emergency operation.
5.3 Testing the Unit
To test the emergency function, press and hold the test switch. The connected lamp(s) should illuminate, and the indicator light should turn off. Release the test switch to return to normal operation. Regular testing is recommended as per local codes (e.g., monthly 30-second tests, annual 90-minute tests).
6. Manutenzjoni
The EBP500 requires minimal maintenance. However, periodic checks are essential to ensure proper operation.
- Test ta' Kull Xahar: Press the test switch for 30 seconds. The emergency lamp should operate.
- Annual Test: Disconnect AC power to the unit for 90 minutes. The emergency lamp should remain illuminated for the entire duration.
- Tindif: Keep the unit and fixture clean and free of dust. Use a dry cloth for cleaning.
- Sostituzzjoni tal-batterija: The EBP500 contains a sealed Ni-Cad battery. As stated on the unit, the entire unit should be replaced when the battery reaches the end of its service life or fails to hold a charge. Do not attempt to replace individual battery cells.
- Rimi: Dispose of the unit in accordance with local regulations for Ni-Cad batteries. The unit is recyclable.
7 Issolvi l-problemi
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Emerġenza lamp does not illuminate during test or power failure. |
|
|
| Indicator light is off during normal AC power. |
|
|
| Emerġenza lamp duration is less than 90 minutes. |
|
|
Jekk il-passi għas-soluzzjoni tal-problemi ma jsolvux il-problema, ikkuntattja persunal tas-servizz kwalifikat.
8. Speċifikazzjonijiet
- Mudell: EBP500
- Input Voltage: 120/277 VAC, 60 Hz
- Tip ta 'batterija: Sealed Ni-Cad
- Batterija Voltage: 4.8V
- Kapaċità tal-batterija: 2 AH
- Ħin tal-Iċċarġjar: 24 sigħat (minimu)
- Emergency Operation Time: 90 minutes (minimum)
- Maximum Discharge: 0.27A f'120V, 0.25A f'277V
- Materjal tal-Każ: Steel (Alloy Steel)
- Tip ta 'Immuntar: Ħajt
- Kompatibbli Lamp Tipi: T5/T5HO/T8/T12/CFL 2G11/Circular T9/T8/U-
- Ċertifikazzjonijiet: Elenkat UL
- Użabbiltà mill-ġdid: Rikarikabbli
9. Garanzija u Appoġġ
For warranty information or technical support, please contact Sure-Lites customer service. Refer to the product packaging or the Sure-Lites official website for contact details. Please have your model number (EBP500) and purchase date available when contacting support.
This product is designed for long-term reliability when installed and maintained correctly. Adherence to the instructions in this manual will help ensure optimal performance.