1. Introduzzjoni
The Oh’Care Lite Blood Sugar Test Kit is designed for convenient and accurate blood glucose monitoring. This comprehensive kit provides all necessary components for self-testing, ensuring reliable results to help manage your blood sugar levels effectively. It meets the new ISO-15197:2013 requirements for accuracy and precision.

Image: The Oh’Care Lite Blood Sugar Test Kit, showing the glucometer, test strips, lancing device, and lancets.
2. X'inhu Inkluż
Your Oh’Care Lite Blood Sugar Test Kit comes with the following items:
- ISO Standardized Oh’Care Lite Glucometer
- 50x Test Strips with latest biosensor technology
- 50x Lancets
- Apparat Lancing
- Każ tal-Ġarr Deluxe
- Ġurnal ta ’abbord
- Manwali ta' Istruzzjoni

Image: All components included in the Oh’Care Lite Blood Sugar Test Kit, neatly arranged.
3. Twaqqif u l-Ewwel Użu
The Oh’Care Lite Meter is auto-coding, simplifying the setup process. Follow these steps for your first blood glucose test:
- Ipprepara Idejk: Make sure your hands are thoroughly washed and dry.
- Daħħal l-Istrixxa tat-Test: Insert a fresh test strip into the monitor. The meter will automatically recognize the strip.
- Ipprepara l-Apparat tal-Lancejar: Uncap the lancing device and insert a new lancet.
- Aġġusta l-Fond tal-Lancing: Close the cap and adjust the depth setting (1 to 5, with 5 being the deepest) to your comfort level.
- Load Spring: Load the spring by pulling the end handle of the lancing device.
- Prick Finger: Press the lancing device tip against your finger and prick the skin.
- Iġbor Sample: Gently squeeze your finger to form a blood droplet. Wipe away the first droplet and use the second drop as the sample. Place the blood droplet onto the designated area of the test strip.
- Aqra r-Riżultat: Wait approximately 5 seconds for the meter to display your blood glucose reading.

Image: Visual guide illustrating the eight steps for performing a blood glucose test with the Oh’Care Lite kit.

Image: Close-up of the adjustable lancing device, highlighting its five depth settings and the small blood droplet required for testing.
4. Operating Instructions for Accurate Results
To ensure the most accurate results from your Oh’Care Lite Blood Glucose Meter, please adhere to the following guidelines:
- Always ensure your hands are thoroughly washed and dry before testing.
- Wipe away the first droplet of blood and use the second drop as the sample għall-ittestjar.
- Iġbor id-demm sample as soon as the droplet emerges from the pricked finger.
- Avoid multiple touches with the test strip to prevent contamination.
- Keep the contact end of the test strip free from any foreign substance.
- The meter and lancing device feature a slight touch ejection mechanism to release used strips and lancets without direct contact.

Image: Visual guide showing six simple guidelines to achieve the most accurate blood glucose test results.
Video: Official Oh'Care Lite Diabetes Testing Kit demonstration, showing the quality control process for the glucose meter and its precise and accurate readings.
5. Manutenzjoni u Ħażna
Proper maintenance and storage are crucial for the longevity and accuracy of your Oh’Care Lite Blood Sugar Test Kit.
- Store the meter and test strips in the provided deluxe carrying case to protect them from dust, moisture, and extreme temperatures.
- Keep test strip vials tightly closed after removing a strip to prevent exposure to air, which can affect accuracy.
- Clean the meter's exterior with a soft, damp drapp. Tgħaddasx il-miter fl-ilma jew tużax aġenti tat-tindif ħarxa.
- Dispose of used lancets and test strips properly in a sharps container or according to local regulations.
- Regularly check the expiration date on your test strips and lancets. Only use unexpired supplies.
6 Issolvi l-problemi
If you encounter any issues with your Oh’Care Lite Blood Sugar Test Kit, consider the following common troubleshooting tips:
- Qari mhux eżatt: Ensure hands are clean, the correct amount of blood is applied, and test strips are not expired or damaged. Perform a control solution test if available to verify meter and strip accuracy.
- Messaġġi ta' Żball: Refer to the detailed instruction manual for specific error codes and their corresponding solutions. Common errors relate to insufficient blood sample or strip issues.
- Il-miter mhux qed jixgħel: Iċċekkja l-batterija. Ibdelha jekk meħtieġ.
- Difficulty Obtaining Blood Sample: Adjust the lancing device depth setting. Ensure the lancet is new and properly inserted.
For persistent issues or concerns, please contact ijCare customer support.
7. Speċifikazzjonijiet
| Karatteristika | Speċifikazzjoni |
|---|---|
| Isem tal-Mudell | Lite |
| Ħin Operattiv | 5 Sekondi |
| Kompożizzjoni taċ-Ċellola tal-Batterija | Alkalin |
| Dimensjonijiet tal-Prodott | 3.19"T x 2.05"W x 3.19"Għ |
| Manifattur | ijCare |
| ASIN | B084WN1HK7 |
8. Garanzija u Appoġġ
Your Oh’Care Lite Blood Sugar Test Kit comes with a 3-Year Meter Warranty. We encourage you to fill out your warranty information upon receipt of the kit.
If you require assistance or have any questions regarding your product, please do not hesitate to contact ijCare customer support. We are committed to ensuring your satisfaction and proper use of the device.
For more information and support, visit the official ijCare Store: ijCare Store on Amazon.