1. Introduzzjoni
This manual provides essential information for the safe and efficient operation, installation, and maintenance of the Danfoss RT-112 Manual Pressure Switch. The RT-112 is designed for industrial applications, including boiler, air, water, and oil systems, to monitor and control pressure.

Figura 1: Quddiem view of the Danfoss RT-112 Manual Pressure Switch, showing the main housing and pressure connection.
2. Informazzjoni dwar is-Sigurtà
Always adhere to local regulations and safety standards when installing, operating, or maintaining the pressure switch. Failure to do so may result in injury or damage to equipment.
- Ensure power is disconnected before any installation or maintenance work.
- Persunal kwalifikat biss għandu jwettaq l-installazzjoni u l-wajers.
- Verify the pressure switch ratings match the system requirements.
- Protect the device from excessive vibration, moisture, and extreme temperatures.
3. Setup u Installazzjoni
The Danfoss RT-112 is designed for panel mounting and features a screwed connector for pressure lines.
3.1 Immuntar
Mount the pressure switch securely to a panel using appropriate fasteners. Ensure the mounting surface is stable and free from excessive vibration.

Figure 2: The Danfoss RT-112 pressure switch shown with included mounting hardware, including screws and washers.
3.2 Konnessjoni tal-Pressjoni
Connect the pressure line to the 3/8" screwed connector at the bottom of the unit. Use appropriate sealing tape or compound to ensure a leak-free connection.

Figura 3: Dettaljat view of the 3/8" pressure connection, which is a standard threaded fitting for pressure lines.
3.3 Wiring Elettriku
The RT-112 features a Normally Open (NO) contact type and SPDT terminal. Refer to the internal wiring diagram and electrical specifications before connecting to the power supply. Ensure the power source matches the switch's current rating (10 Amps,3 Amps) u voltage rekwiżiti.

Figura 4: Intern view of the pressure switch, displaying the electrical terminals, pressure adjustment scales, and internal components.

Figura 5: Ġenb view of the pressure switch, highlighting the label with electrical ratings and certifications.
4. Istruzzjonijiet Operattivi
The Danfoss RT-112 is a manual pressure switch, requiring manual adjustment for its setpoint and differential.
4.1 Setting Pressure Setpoint
To adjust the pressure setpoint, remove the cover and locate the adjustment knob. Rotate the knob to align the desired pressure value with the indicator. The internal scale provides readings in bar, psig, kg/cm², and kPa.

Figura 6: Fuq view of the pressure switch, showing the manual adjustment knob used to set the pressure threshold.
4.2 Setting Differential
The differential setting determines the pressure difference between the cut-in and cut-out points. Adjust this setting as required for your application, typically found near the main setpoint adjustment.
5. Manutenzjoni
The Danfoss RT-112 is designed for minimal maintenance. Regular inspections are recommended to ensure optimal performance and longevity.
- Spezzjoni Viżwali: Periodically check for any signs of physical damage, corrosion, or leaks around the pressure connection.
- Integrità tal-Konnessjoni: Ensure all electrical and pressure connections remain tight and secure.
- Tindif: Keep the exterior of the unit clean and free from dust or debris. Do not use abrasive cleaners.
- Kontroll tal-Kalibrazzjoni: If precise pressure control is critical, periodically verify the switch's setpoint accuracy using a calibrated pressure gauge.
6 Issolvi l-problemi
This section provides guidance for common issues encountered with the Danfoss RT-112 pressure switch.
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Switch does not activate at setpoint | Incorrect setpoint; wiring issue; pressure not reaching setpoint; clogged pressure line | Verify setpoint; check wiring connections; confirm system pressure; inspect pressure line for obstructions. |
| Switch activates erratically | Vibration; pressure fluctuations; faulty switch | Reduce vibration; stabilize pressure; replace switch if faulty. |
| Leak at pressure connection | Improper sealing; damaged threads | Re-apply sealing tape/compound; inspect threads for damage. |
7. Speċifikazzjonijiet Tekniċi
| Attribut | Valur |
|---|---|
| Brand | Danfoss |
| Mudell | RT-112 |
| Mod ta' Operazzjoni | Manwal |
| Klassifikazzjoni kurrenti | 10 Amps,3 Amps |
| Tip ta' Kuntatt | Normalment Miftuħ |
| Tip ta' Konnettur | Invitat |
| Terminal | Spdt |
| Tip ta 'Ċirkwit | 2-mod |
| Tip ta 'Immuntar | Immonta fuq il-Panew |
| Tip ta' Attwatur | Lieva taċ-ċappetta |
| Kuntatt Materjal | Ram |
| Dimensjonijiet tal-Pakkett | 9 x 4.5 x 3 pulzieri |
| Piż | 3.3 Liri |
| Data L-Ewwel Disponibbli | 29 ta’ Jannar, 2020 |

Figure 7: Common industrial applications for the Danfoss RT-112 pressure switch, including HVAC, turbines, heavy engineering, and air conditioning systems.
8. Garanzija u Appoġġ
For warranty information and technical support, please contact Danfoss customer service or visit the official Danfoss websit. Żomm l-irċevuta tax-xiri tiegħek għal pretensjonijiet ta' garanzija.
Protection plans may be available for extended coverage. Refer to your purchase details for more information on available protection plans.
Għal aktar għajnuna, tista' żżur il- Ħanut Danfoss fuq Amazon.