3M 60927

3M Mercury Vapor/Organic Vapor/Acid Gas Cartridge/Filter P100 60927 User Manual

Mudell: 60927 | Marka: 3M

1. Introduzzjoni

This manual provides essential information for the proper use, maintenance, and storage of the 3M Mercury Vapor/Organic Vapor/Acid Gas Cartridge/Filter P100, model 60927. This product is designed to be used with compatible 3M half and full facepiece respirators featuring a bayonet-style connection.

The 3M 60927 cartridge/filter is NIOSH-approved for protection against mercury vapor, chlorine, sulfur dioxide, organic vapor, and hydrogen sulfide. It also includes a P100 particulate filter for protection against certain oil and non-oil based particulates.

3M 60927 Cartridge/Filter, front view

Figura 1: Quddiem view of the 3M Mercury Vapor/Organic Vapor/Acid Gas Cartridge/Filter P100 60927. The magenta color indicates its specific protection capabilities.

2. Informazzjoni dwar is-Sigurtà

TWISSIJA: Misuse of 3M industrial and occupational products may result in injury, sickness, death, or property damage. These products are intended for workplace use by trained industrial and occupational customers. They are not intended for consumer use.

For help with product selection and use, consult your on-site safety professional, industrial hygienist, or other subject matter expert.

3. Setup u Installazzjoni

The 3M 60927 Cartridge/Filter is designed for easy attachment to compatible 3M half and full facepiece respirators using a bayonet connection system.

3.1 Tagħmir Meħtieġa

3.2 Passi ta' Installazzjoni

  1. Spezzjona l-Komponenti: Before each use, inspect the cartridge/filter and the respirator facepiece for any signs of damage, cracks, or wear. Do not use damaged equipment.
  2. Allinja l-Kartriġ: Align the bayonet connection on the cartridge with the corresponding receptacle on the respirator facepiece. The cartridge should be oriented so the 3M logo and model number are visible and facing outwards.
  3. Attach Cartridge: Push the cartridge onto the receptacle and twist clockwise approximately a quarter turn until it clicks into place. Ensure both cartridges (if using a dual-cartridge respirator) are securely attached.
  4. Agħmel Kontroll tas-Siġill: Conduct a positive and/or negative pressure user seal check as described in your respirator's instruction manual to ensure a proper fit and seal.
Qiegħ view of 3M 60927 Cartridge/Filter showing bayonet connection

Figura 2: Qiegħ view of the 3M 60927 cartridge, highlighting the bayonet connection point for attachment to a respirator.

4. Istruzzjonijiet Operattivi

Once properly installed on a compatible 3M respirator and a successful user seal check has been performed, the 3M 60927 cartridge/filter provides respiratory protection.

Worker wearing a respirator with cartridges in an industrial setting

Figure 3: An industrial worker utilizing respiratory protection, demonstrating a typical application environment for the 3M 60927 cartridge.

5. Manutenzjoni u Ħażna

5.1 Sostituzzjoni tal-Kartriġ

Cartridges must be replaced when:

To replace, twist the used cartridge counter-clockwise to detach it from the respirator. Dispose of used cartridges according to local regulations. Install new cartridges following the "Setup and Installation" steps.

5.2 Ħażna

Store unused cartridges in their original, sealed packaging in a clean, dry, and cool environment, away from direct sunlight and contaminants. Do not store near chemicals or in areas with high humidity.

6 Issolvi l-problemi

ProblemaKawża PossibbliSoluzzjoni
Smell/Taste of ContaminantsCartridge breakthrough, improper seal, cartridge expired, wrong cartridge type.Immediately leave contaminated area. Replace cartridges. Re-check seal. Ensure correct cartridge for hazard.
Diffikultà biex tieħu n-nifsCartridges clogged with particulates, high breathing rate, physical exertion.Immediately leave contaminated area. Replace cartridges. Reduce exertion.
Cartridge not attaching securelyImproper alignment, damaged bayonet connection on cartridge or respirator.Ensure correct alignment and twist until click. Inspect for damage; replace if necessary.
Discomfort or IrritationImproper fit, allergic reaction to materials, contaminants bypassing seal.Re-adjust respirator fit. Perform seal check. Consult safety professional.

7. Speċifikazzjonijiet

KaratteristikaDettall
Numru tal-Mudell60927
Brand3M
Tip ta' ProtezzjoniMercury Vapor, Organic Vapor, Acid Gas, P100 Particulate
Approvazzjoni tan-NIOSHIva
Tip ta' KonnessjoniBajjunetta
KulurMagenta
Dimensjonijiet tal-Prodott (L x W x H)17.3 x 15.1 x 11.1 inches (packaging dimensions, individual cartridge smaller)
Data L-Ewwel Disponibbli14 ta’ Jannar, 2020
Manifattur3M

8. Garanzija u Appoġġ

3M industrial and occupational products are intended, labeled, and packaged for sale to trained industrial and occupational customers for workplace use. Unless specifically stated otherwise on the applicable product packaging or literature, these products are not intended, labeled, or packaged for sale to or use by consumers.

For additional product information, technical support, or warranty details, please visit the official 3M website or contact your local 3M representative. It is crucial to select and use products in compliance with applicable health and safety regulations and standards (e.g., U.S. OSHA, ANSI), as well as all product literature, user instructions, warnings, and other limitations.

Riżorsi onlajn: www.3M.com