1. Introduzzjoni
This manual provides essential information for the safe and effective installation, operation, and maintenance of your Leviton LB260-GS 60A 2-Pole Plug-On Smart GFCI Branch Circuit Breaker. Please read all instructions carefully before proceeding with installation or use.
The Leviton LB260-GS is a Smart Ground Fault Circuit Interrupter (GFCI) branch circuit breaker designed for use in Leviton Load Centers. It features hydraulic magnetic technology for reliable operation across a wide temperature range and integrates with the My Leviton app for enhanced monitoring and control.
2. Informazzjoni dwar is-Sigurtà
WARNING: RISK OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH.
- This product must be installed and serviced by qualified electrical personnel only.
- Turn off all power to the electrical panel before working on or installing the circuit breaker.
- Dejjem uża voltage detector to confirm power is off before touching any wires or components.
- Follow all local and national electrical codes and regulations.
- Tużax dan l-apparat jekk jidher bil-ħsara.
In-nuqqas ta' segwitu ta' dawn l-istruzzjonijiet jirriżulta f'mewt jew korriment serju.
3. Prodott Aktarview
The Leviton LB260-GS is a 2-pole, 60-Amp Smart GFCI circuit breaker. It is designed to protect against ground faults, which can cause severe electrical shock. Its hydraulic magnetic trip technology ensures consistent performance from -40°C to 85°C (-40°F to 185°F).

Stampa 3.1: Quddiem view of the Leviton LB260-GS Smart GFCI Circuit Breaker. Shows the ON/OFF switch, 60 Amp rating, GFCI indicator, and wireless communication symbol.

Stampa 3.2: Ġenb view of the Leviton LB260-GS Smart GFCI Circuit Breaker, illustrating its compact design for plug-on installation.

Stampa 3.3: Wara view of the Leviton LB260-GS Smart GFCI Circuit Breaker, highlighting the plug-on bus connections for easy installation into a Leviton Load Center.
Karatteristiċi ewlenin:
- Integrazzjoni intelliġenti: Connects with the My Leviton app for energy consumption data, enhanced safety alerts, and remote control.
- Installazzjoni faċli: Revolutionary plug-on design allows for quick and tool-free installation into Leviton Load Centers.
- Teknoloġija Manjetika Idrawlika: Ensures precise and reliable tripping characteristics across a wide temperature range without derating.
- Sigurtà Mtejba: Features patented reset lockout technology, preventing reset if ground fault protection is compromised.
4. Setup u Installazzjoni
Professional installation by a qualified electrician is required.
- Ipprepara ċ-Ċentru tat-Tagħbija: Ensure all power to the Leviton Load Center is turned OFF at the main service disconnect. Verify with a voltagtester.
- Konnessjonijiet tal-Wajer: The Leviton Load Center design allows branch phase and neutral connections to be made directly on the panel bus bars without the circuit breaker present. Land the branch circuit wires (hot and neutral) to the appropriate terminals on the load center bus.
- Installa l-Breaker: Align the LB260-GS circuit breaker with the desired position on the load center bus. Firmly push the breaker onto the bus until it clicks into place. No additional wiring to the breaker itself is required.
- Wajer tal-art: Connect the ground wire from the branch circuit to the ground bar in the load center.
- Ivverifika l-Installazzjoni: Iċċekkja darbtejn il-konnessjonijiet kollha għal sigurtà u qagħda tajba.
- Irrestawra l-Enerġija: Once installation is complete and verified, restore power to the load center.
For a visual guide on installing Leviton Load Centers and circuit breakers, please refer to the video below:
Vidjo 4.1: An instructional video demonstrating the installation process for Leviton Load Centers and their plug-on circuit breakers, including wiring and breaker placement.
5. Istruzzjonijiet Operattivi
Operazzjoni manwali:
- Tixgħel: Push the breaker handle firmly to the "ON" position.
- Itfi: Push the breaker handle firmly to the "OFF" position.
- Ir-Resetjar ta' Breaker li Qabbad: If the breaker trips, the handle will move to a center position. To reset, first push the handle firmly to the "OFF" position, then push it to the "ON" position. If the breaker immediately trips again, there may be an electrical fault that needs to be addressed.
GFCI Test and Reset:
The GFCI function should be tested monthly to ensure proper operation.
- Kun żgur li l-interruttur ikun fil-pożizzjoni "ON".
- Press the "TEST" button on the face of the breaker. The breaker should immediately trip to the center position.
- To restore power, push the handle firmly to the "OFF" position, then to the "ON" position.
- If the breaker does not trip when the "TEST" button is pressed, or if it does not reset, the GFCI function may be faulty. Contact a qualified electrician for inspection and replacement.
Smart Features (My Leviton App):
The LB260-GS integrates with the My Leviton app, providing advanced functionality:
- Monitoraġġ tal-Enerġija: View real-time and historical energy consumption data for the circuit.
- Kontroll mill-bogħod: Turn the breaker ON or OFF remotely via the app.
- Notifiki: Receive alerts for electrical anomalies, tripped breakers, or other status changes.
- Awto-Test: The smart breaker performs self-tests and reports status to the app.
Refer to the My Leviton app documentation for detailed instructions on connecting and utilizing smart features.
6. Manutenzjoni
- Monthly GFCI Test: Perform the GFCI test as described in Section 5.
- Spezzjoni Viżwali: Periodically inspect the circuit breaker for any signs of physical damage, discoloration, or loose connections. If any issues are observed, contact a qualified electrician.
- Tindif: Keep the breaker and surrounding area clean and free of dust and debris. Do not use liquid cleaners directly on the breaker.
7 Issolvi l-problemi
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| L-interruttur jitlaq ta' spiss. | Overload, short circuit, or ground fault. | Reduce load on the circuit. Check for damaged appliances or wiring. If it's a GFCI trip, check for ground faults in connected equipment. Contact an electrician if the problem persists. |
| Breaker does not reset after tripping. | Persistent fault (overload, short circuit, or ground fault) or internal breaker damage. | Ensure the handle is pushed fully to "OFF" before attempting to reset to "ON". If it still won't reset, a fault is likely present. Do not force the breaker. Contact a qualified electrician. |
| GFCI test button does not trip the breaker. | Mekkaniżmu GFCI difettuż. | The breaker may be defective. It must be replaced by a qualified electrician. |
| No data in My Leviton app / Breaker not connecting. | Network issue, app configuration error, or data hub issue. | Ensure your Wi-Fi network is active and the Leviton data hub (if applicable) is connected. Check app settings and follow in-app troubleshooting guides. |
For issues not covered here, contact Leviton customer support or a qualified electrician.
8. Speċifikazzjonijiet
| Attribut | Dettall |
|---|---|
| Brand | Leviton |
| Numru tal-Mudell | LB260-GS |
| Klassifikazzjoni kurrenti | 60 Amps |
| Numru ta 'Pollakki | 2 |
| Voltage | 120 / 240 VAC |
| Tip ta 'Circuit Breaker | GFCI (Ground Fault Circuit Interrupter) |
| Trip Technology | Hydraulic Magnetic |
| Klassifikazzjoni tal-Interruzzjoni | 10KA |
| Tip ta 'Immuntar | Panel Mounting (Plug-On) |
| Temperatura operattiva | -40°C sa 85°C (-40°F sa 185°F) |
| Dimensjonijiet | 4 x 2.5 x 3.9 pulzieri (approssimattiv) |
| Piż | 13.6 uqija |
| UPC | 078477815342 |
9. Garanzija u Appoġġ
Garanzija:
This Leviton product is covered by a Garanzija Limitata ta' 10 Snin. For full details regarding warranty terms and conditions, please refer to the official Leviton warranty statement available on their websit jew ikkuntattja l-appoġġ tal-klijent.
Appoġġ għall-Klijent:
For technical assistance, product information, or warranty claims, please contact Leviton customer support through their official webis-sit jew l-informazzjoni ta' kuntatt ipprovduta mal-imballaġġ tal-prodott tiegħek.
You can visit the official Leviton website for more resources: www.leviton.com