1. Introduzzjoni
This manual provides detailed instructions for the Waveshare Industrial Modbus RTU 8-Channel Relay Module. This module is designed for industrial control applications, offering reliable relay switching via an RS485 interface using the Modbus RTU protocol. It features multiple isolation protection circuits for enhanced safety and stability.
Il-karatteristiċi ewlenin jinkludu:
- Configurable device address (1-255) for multi-device cascading on an RS485 bus.
- Flash-on, flash-off function for timed relay activation.
- Onboard unibody power supply isolation for stable isolated voltage.
- Onboard unibody magnetic isolation for signal integrity, high reliability, and strong anti-interference.
- It-TVS abbord (Transient Voltage Suppressor) for surge and transient spike voltage suppression, providing lightning protection and anti-electrostatic capabilities.
- Onboard optocoupler isolation to prevent interference from external high-voltage ċirkwiti.
- Reverse-proof circuit to protect against accidental damage from incorrect power connection.
- High-quality relays with a contact rating of ≤10A 250VAC/30VDC.
- Għeluq tal-plastik ABS immuntat fuq il-binarji għal installazzjoni faċli u użu sikur.
- Three LEDs indicating MCU status and signal transceiving status.
2. Kontenut tal-Pakkett
The standard package for the Waveshare Industrial Modbus RTU 8-Channel Relay Module includes the following items:
- Waveshare Modbus RTU 8-Channel Relay Module
- Power adapter (may vary by region)

Image 2.1: The image displays the Waveshare Modbus RTU 8-Channel Relay Module along with a power adapter and a USB to RS485 converter (converter not included with the module).
3. Hardware Matulview
The Modbus RTU 8-Channel Relay Module is designed with robust components and protection circuits. Understanding its internal structure is crucial for proper use and troubleshooting.

Immaġni 3.1: Din l-immaġni tipprovdi deskrizzjoni dettaljata view of the module's internal components, highlighting the high-quality relays, optocoupler isolation, magnetic signal isolation, power supply isolation, TVS lightning & ESD protection, and thickened tracks for large current.
3.1. Komponenti Ewlenin
- High Quality Relay: Ensures reliable switching for connected devices.
- Iżolament tal-Optocoupler: Provides electrical isolation between control and load circuits.
- Magnetic Signal Isolation: Enhances signal integrity and anti-interference capabilities.
- Iżolament tal-Provvista tal-Enerġija: Isolates the power supply for stability and safety.
- Protezzjoni mis-Sajjetti u l-ESD tat-TVS: Jipproteġi kontra l-volumtage surges and electrostatic discharge.
- Thickened Track for Large Current: Designed to handle higher current loads safely.
3.2. Disinn tal-Għeluq
The module is housed in a rail-mounted ABS plastic enclosure, facilitating easy installation in industrial environments and ensuring safe operation.

Image 3.2: The image shows the module's rail-mounted ABS plastic enclosure, designed for easy and secure installation.
4. Setup
Follow these steps to set up your Waveshare Industrial Modbus RTU 8-Channel Relay Module.
4.1. Konnessjoni tal-Enerġija
- Connect the provided power adapter to the DC 5V input terminal of the relay module. Ensure the polarity is correct to prevent damage.
- Verify that the power LED indicator on the module illuminates, indicating successful power-on.
4.2. RS485 Communication Setup
The module communicates via RS485. Multiple devices can be cascaded on the RS485 bus. If communication distance is long, RS485 repeaters may be necessary.
- Connect the RS485 A+, B-, and GND terminals of the module to your RS485 master device (e.g., a computer with a USB to RS485 converter, or a PLC).
- Ensure correct wiring: A+ to A+, B- to B-, and GND to GND.
- For multiple modules, connect them in a daisy-chain configuration as shown in the diagram below.

Image 4.1: This diagram illustrates how to connect multiple Modbus RTU relay modules in a daisy-chain configuration using an RS485 bus, typically connected to a USB to RS485 converter.
4.3. Device Address Configuration
Each module on the RS485 bus must have a unique device address, configurable from 1 to 255. Refer to the Modbus RTU protocol documentation for your specific software or controller to set the device address.
5. Istruzzjonijiet Operattivi
The Waveshare Modbus RTU 8-Channel Relay Module operates using the standard Modbus RTU protocol over an RS485 interface. This section outlines how to control the relays.
5.1. Modbus RTU Protocol
The module responds to standard Modbus RTU commands. You will typically use Modbus function codes to read coil status, write single coils, or write multiple coils to control the relays. Consult the Modbus RTU specification for detailed command structures.
5.2. Relay Control
Each of the 8 channels corresponds to a relay. Relays can be individually controlled (turned ON/OFF) using Modbus commands. The module also supports a flash-on, flash-off function, allowing you to activate a relay for a specified duration and then automatically deactivate it.
5.3. Indikaturi LED
- STA (Status) LED: Keeps flashing when the MCU is working normally.
- TXD (Transmit) LED: Lights up when the module is sending data.
- RXD (Receive) LED: Lights up when the module is receiving data.
6. Konnessjoni tar-Relay
The module's relays have a contact rating of ≤10A 250VAC/30VDC. This allows direct control of various AC and DC devices. Always ensure that the connected load does not exceed the relay's maximum current and voltage klassifikazzjonijiet.
6.1. AC 220V Device Connection
For connecting AC 220V devices, ensure proper insulation and safety precautions. Connect the AC load to the COM (Common) and NO (Normally Open) terminals of the desired relay channel.
6.2. DC 30V Device Connection
For connecting DC devices up to 30V, connect the DC load to the COM (Common) and NO (Normally Open) terminals of the desired relay channel. Ensure correct polarity for DC loads.

Image 6.1: This diagram illustrates how to connect both AC 220V and DC 30V devices to the relay module. It shows wiring for a light bulb (AC) and a motor (DC) using the COM and NO terminals, with the module powered by DC 5V.
7. Applikazzjonijiet
The Waveshare Industrial Modbus RTU 8-Channel Relay Module is versatile and suitable for a wide range of applications:
- Kontroll Industrijali: Valve control, pump station control, and unattended industrial control systems.
- Dar Intelliġenti: Controlling appliances like air conditioners, access control systems, purifiers, and water heaters.
- Intelligent Agriculture: Kontroll tal-muturi tal-purtieri tal-bibien, blowers tal-arja, u tagħmir agrikolu ieħor.
- Tnissil u Biedja: Controlling ventilators, lighting, water supply systems, and feeding systems.

Image 7.1: This image displays four common application areas for the relay module: Industrial Control, Smart Home, Intelligent Agriculture, and Breeding & Farming, showing examples of equipment that can be controlled.
8. Speċifikazzjonijiet
Detailed technical specifications for the Modbus RTU Relay Module:
| Karatteristika | Modbus RTU Relay | Modbus RTU Relay (B) |
|---|---|---|
| Provvista tal-Enerġija | 5V | 7-36V |
| Interface tal-Komunikazzjoni | RS485 | |
| rata baud | 4800, 9600, 19200, 38400, 57600, 115200, 128000, 256000 | |
| Format ta' Komunikazzjoni Predefinit | 9600, N, 8, 1 | |
| Kanali tar-Relay | 8 | |
| Formola ta' Kuntatt | 1NO 1NC | |
| Kuntatt Klassifikazzjoni | ≤10A 250VAC/30VDC | |
| Protokoll ta' Komunikazzjoni | Protokoll standard Modbus RTU | |
| Indirizz RS485 | 1-255 | |
| Indikaturi LED | STA: L-indikatur tal-MCU, jibqa' jteptep meta l-MCU jaħdem normalment TXD: Indikatur TX, jixgħel meta tintbagħat id-dejta RXD: Indikatur RX, jixgħel meta jirċievi d-dejta | |
9. Manutenzjoni
The Waveshare Industrial Modbus RTU 8-Channel Relay Module is designed for robust and reliable operation with minimal maintenance. To ensure longevity and optimal performance:
- Żomm Nadif: Periodically clean the exterior of the module with a soft, dry cloth. Avoid using harsh chemicals or abrasive materials.
- Kundizzjonijiet Ambjentali: Operate the module within its specified temperature and humidity ranges. Avoid exposure to excessive dust, moisture, or corrosive environments.
- Integrità tal-Konnessjoni: Regularly check all wiring connections (power, RS485, and relay loads) to ensure they are secure and free from corrosion or damage.
- Aġġornamenti tal-Firmware: Iċċekkja l-Waveshare uffiċjali website for any available firmware updates that may improve performance or address issues. Follow update instructions carefully.
10 Issolvi l-problemi
If you encounter issues with your Waveshare Industrial Modbus RTU 8-Channel Relay Module, refer to the following troubleshooting tips:
- Il-Modulu Mhux Jixgħel:
- Ensure the power adapter is correctly connected and providing the specified voltage (5V għal dan il-mudell).
- Check the power outlet and cable for functionality.
- Verify the power LED indicator. If it's off, there might be a power issue.
- No RS485 Communication:
- Verify RS485 wiring: A+ to A+, B- to B-, and GND to GND.
- Check the baud rate, data bits, parity, and stop bits settings in your Modbus master software. These must match the module's default or configured settings (e.g., 9600, N, 8, 1).
- Ensure the module's RS485 device address is unique and correctly configured in your master software.
- Observe the TXD and RXD LEDs. If they are not flashing during communication attempts, check wiring and software settings.
- For long distances or multiple devices, consider adding RS485 terminators or repeaters.
- Ir-Relays Mhux Qed Jattivaw:
- Confirm that the module is powered on and communicating correctly (check communication LEDs).
- Verify the Modbus commands sent to activate the specific relay channels.
- Check the wiring of the load connected to the relay. Ensure the load's power supply is active and within the relay's contact rating.
- Kun żgur li t-tagħbija nnifisha hija funzjonali.
- Operazzjoni intermittenti:
- Check for loose connections on power, RS485, and relay terminals.
- Ensure the operating environment is stable and free from excessive electrical noise or temperature fluctuations.
- Verify that the power supply is stable and sufficient for both the module and the connected loads.
11. Dimensjonijiet tal-Kontorn
The physical dimensions of the Waveshare Industrial Modbus RTU 8-Channel Relay Module are provided below for installation planning.

Image 11.1: This image provides detailed measurements of the module, including its length (145mm), width (90mm), and height (40mm), along with other specific dimensions for mounting.
12. Garanzija u Appoġġ
Waveshare products are designed for quality and reliability. For specific warranty information, please refer to the warranty policy provided with your purchase or visit the official Waveshare website. For technical support, documentation, and additional resources, please visit the Waveshare support portal or contact their customer service directly.
Waveshare Uffiċjali Websit: www.waveshare.com