1. Introduzzjoni

This manual provides essential information for the proper installation, operation, and maintenance of the EKWB EK-Quantum Kinetic TBE 300 D5 PWM D-RGB Pump Reservoir - Plexi. Please read this manual thoroughly before proceeding with installation to ensure optimal performance and longevity of your product.

2. Prodott Aktarview

The EK-Quantum Kinetic TBE D5 combo unit is a pump-reservoir assembly designed for liquid cooling systems. It features addressable D-RGB lighting and integrates a genuine D5 pump. The reservoir is constructed with high-quality acrylic for the tube, bottom, and top, sealed with an EPDM O-ring. It includes six G1/4" ports for flexible loop configuration, with one top port featuring a pre-installed nickel-plated brass internal tube to prevent coolant splashing when used as an inlet. The integrated D-RGB lighting is compatible with major motherboard RGB sync technologies.

EK-Quantum Kinetic TBE 300 D5 PWM D-RGB Pump Reservoir - Plexi, full view

Immaġni 1: Sħiħa view of the EK-Quantum Kinetic TBE 300 D5 PWM D-RGB Pump Reservoir, showcasing its transparent plexi tube and integrated pump base.

3. Karatteristiċi

  • Integrated tube reservoir and D5 pump combo unit.
  • Sophisticated addressable D-RGB lighting for customizable aesthetics.
  • Total of six G1/4" ports for versatile liquid cooling loop configurations.
  • Reservoir tube diameter: 60mm.
  • Overall unit height: 300mm.
  • Reservoir free volume: 405mL.
  • D-RGB connector: Standard 3-pin (5V, Digital, Blocked, Ground).
  • Compatible with longer acrylic tubes from EK-RES X3 series reservoirs for potential upgrades.
Close-up of the EK-Quantum Kinetic TBE 300 D5 PWM D-RGB Pump Reservoir base

Immaġni 2: Mill-qrib view of the pump base and lower reservoir section, highlighting the "Kinetic" branding and G1/4" port locations.

4. Speċifikazzjonijiet Tekniċi

KomponentSpeċifikazzjoni
Tip ta' MuturMutur sferiku kommutat elettronikament
Vol ikklassifikattage12V DC
Konsum tal-Enerġija23W
Maximum Pressure Head3.9m
Fluss Massimu1500 L/h
Maximum System Temperature60°C
Konnettur tal-Enerġija4-Pin Molex u 4-Pin PWM FAN konnettur
Reservoir Diameter60mm
Reservoir Free Volume405mL
Overall Unit Height300mm
D-RGB ConnectorStandard 3-pin (5+, Digital, Blocked, Ground)
MaterjalAcrylic, Brass
Dimensjonijiet tal-Prodott (L x W x H)3.59" x 3.07" x 11.73"
Piż1.92 Liri

5. Kontenut tal-Pakkett

The following items are included in the EK-Quantum Kinetic TBE 300 D5 PWM D-RGB package:

  • EK-Quantum Kinetic TBE 300 D5 PWM D-RGB unit
  • Mounting clip with rubber insert
  • Self-adhesive mounting hole pattern sticker
  • Mounting mechanism (including required Allen keys)
Fuq view of the EK-Quantum Kinetic TBE 300 D5 PWM D-RGB Pump Reservoir

Immaġni 3: Fuq view of the reservoir, showing the G1/4" ports and the internal tube for inlet configuration.

6. Setup u Installazzjoni

Proper installation is crucial for the performance and safety of your liquid cooling system. It is recommended to consult the detailed installation guide available on the EKWB official website for step-by-step instructions specific to your system configuration.

  1. Preparazzjoni: Ensure all components are present and undamaged. Plan your loop layout, considering inlet and outlet port usage.
  2. Immuntar: Use the provided mounting clip and mechanism to securely attach the pump-reservoir unit to your chassis. The self-adhesive mounting hole pattern sticker can assist in precise placement.
  3. Konnessjonijiet tal-Port: Connect your G1/4" fittings and tubing to the desired ports. The top port with the pre-installed internal tube is ideal for an inlet to minimize splashing.
  4. Konnessjonijiet elettriċi: Connect the 4-Pin Molex connector for pump power and the 4-Pin PWM FAN connector to your motherboard or fan controller for speed control. Connect the 3-pin D-RGB connector to a compatible addressable RGB header on your motherboard or controller.
  5. Ittestjar tat-tnixxija: Before powering on your system, perform a thorough leak test using a dedicated leak tester or by running the pump with only the power connected (without powering other PC components) for at least 24 hours.
Ġenb view of the EK-Quantum Kinetic TBE 300 D5 PWM D-RGB Pump Reservoir

Immaġni 4: Ġenb view of the pump-reservoir combo, illustrating its cylindrical form factor and mounting bracket attachment point.

7. Istruzzjonijiet Operattivi

Once installed and leak-tested, the EK-Quantum Kinetic TBE 300 D5 PWM D-RGB is ready for operation.

  • Filling the Loop: Fill the reservoir with appropriate liquid cooling fluid. Ensure the reservoir remains adequately filled during the initial filling process to prevent the pump from running dry.
  • Ħruġ ta' Arja: Operate the pump at a low to moderate speed to circulate coolant and remove air bubbles from the loop. Tilt your system gently to help dislodge trapped air. Refill the reservoir as needed.
  • Kontroll PWM: The D5 PWM pump allows for speed control via a 4-pin PWM signal from your motherboard or a dedicated fan controller. Adjust pump speed based on your cooling requirements and noise preferences.
  • D-RGB Control: The integrated D-RGB lighting can be controlled using compatible motherboard software (e.g., ASUS Aura Sync, MSI Mystic Light Sync, Gigabyte RGB Fusion) or a standalone D-RGB controller connected to the 3-pin header.
EK-Quantum Kinetic TBE 300 D5 PWM D-RGB Pump Reservoir with D-RGB lighting active

Image 5: The pump-reservoir unit with its D-RGB lighting illuminated, demonstrating the aesthetic capabilities.

8. Manutenzjoni

Regular maintenance ensures the longevity and efficiency of your liquid cooling system.

  • Sostituzzjoni tal-Coolant: It is recommended to replace the coolant every 6-12 months, depending on the coolant type and system usage, to prevent buildup and maintain optimal performance.
  • Tlaħliħ tas-Sistema: When replacing coolant, consider flushing the entire loop with distilled water or a dedicated cleaning solution to remove any accumulated debris or old coolant residue.
  • Spezzjoni: Periodically inspect tubing, fittings, and the reservoir for any signs of leaks, discoloration, or material degradation.
  • Tindif tal-Pompa: If flow issues occur, the pump impeller can be accessed and cleaned. Refer to the EKWB website for specific disassembly instructions for the D5 pump.

9 Issolvi l-problemi

Din it-taqsima tindirizza kwistjonijiet komuni li tista’ tiltaqa’ magħhom.

  • No Pump Operation:
    • Verify the 4-Pin Molex power connector is securely connected to the power supply.
    • Kun żgur li l-provvista tal-enerġija qed taħdem sew.
    • Check the 4-Pin PWM FAN connector for proper connection to the motherboard/controller and that the fan header is enabled in BIOS/UEFI.
  • Poor Flow/Low Performance:
    • Check for air bubbles trapped in the loop. Bleed the system thoroughly.
    • Ensure the reservoir is adequately filled with coolant.
    • Inspect for kinks in tubing or obstructions in water blocks/radiators.
    • Verify pump speed settings in your motherboard BIOS or software.
  • Id-Dawl D-RGB Mhux Jaħdem:
    • Confirm the 3-pin D-RGB connector is correctly attached to a 5V addressable RGB header (not a 12V RGB header).
    • Check D-RGB software settings on your motherboard or external controller.
    • Ensure the D-RGB header on your motherboard is enabled in BIOS/UEFI.
  • Tnixxijiet:
    • Immediately shut down the system.
    • Identify the source of the leak. Tighten fittings, replace O-rings, or replace damaged components as necessary.
    • Always perform a leak test after any adjustments or repairs.

10. Garanzija u Appoġġ

For warranty information, technical support, or further assistance, please visit the official EK Water Blocks webis-sit jew ikkuntattja l-appoġġ għall-klijenti tagħhom direttament. Żomm il-prova tax-xiri tiegħek għal talbiet ta' garanzija.

Uffiċjali Websit: www.ekwb.com