1. Introduzzjoni
The Total Automatic Pump Control TWPS101 is an advanced device designed to automate the operation of water pumps. It effectively manages pump activation and deactivation based on water pressure, ensuring a consistent water supply and protecting the pump from dry running. This unit is suitable for various domestic and industrial applications, offering reliable and efficient pump management.
Key features include a robust design with IP65 protection, a maximum current capacity of 10A, and compatibility with standard 220-240V power supplies. Its integrated control system eliminates the need for traditional pressure tanks and pressure switches, simplifying installation and maintenance.
2. Istruzzjonijiet tas-Sigurtà
Please read and understand all safety instructions before installing, operating, or performing maintenance on the Total Automatic Pump Control. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage.
- Sigurtà Elettrika: Always disconnect power to the unit before performing any installation, maintenance, or troubleshooting. All electrical connections must be performed by a qualified electrician in accordance with local electrical codes and regulations. Ensure proper grounding.
- Pressjoni tal-Ilma: Do not exceed the maximum operating pressure of 10 bar (145 psi). Operating beyond this limit can damage the unit and connected plumbing.
- Protezzjoni Ambjentali: The unit has an IP65 protection rating, meaning it is protected against dust ingress and low-pressure water jets from any direction. However, it is not designed for submersion. Install in a location protected from direct heavy rain or prolonged exposure to water.
- Temperatura: Do not operate the unit in environments where the temperature exceeds 60°C.
- Immuntar: Ensure the unit is securely mounted on a stable surface to prevent vibration and damage.
- Tfal u Pets: Żomm l-unità fejn ma jintlaħaqx mit-tfal u l-annimali domestiċi.
3. Komponenti Overview
The Total Automatic Pump Control TWPS101 features a compact design with clearly labeled indicators and connection points.

Stampa 3.1: Quddiem view of the Total Automatic Pump Control TWPS101, showing the control panel with Power On, Pump On, Failure indicators, and the Restart button. The main body and pipe connections are also visible.

Stampa 3.2: Ġenb view of the pump control unit, highlighting the 1-inch pipe diameter inlet and outlet connections, and the sealed cable entry points.
Komponenti ewlenin:
- Panel tal-Kontroll: Located on the front, it includes LED indicators and a restart button.
- Indikatur mixgħul: Green LED, illuminates when the unit receives power.
- Pump On Indicator: Yellow LED, illuminates when the pump is actively running.
- Indikatur tal-falliment: Red LED, illuminates to indicate an error condition, such as dry running.
- Buttuna Nerġgħu: Used to reset the unit after a failure or power interruption.
- Portijiet tad-Dħul/Ħruġ: 1-inch threaded connections for water input and output.
- Electrical Connection Points: Sealed entries for power supply and pump wiring.
4. Speċifikazzjonijiet Tekniċi
The following table details the technical specifications of the Total Automatic Pump Control TWPS101:
| Speċifikazzjoni | Valur |
|---|---|
| Vol ikklassifikattage | 220-240V |
| Frekwenza | 50/60Hz |
| Pressjoni tal-Bidu | 1.5 bar (22 psi) |
| Max. Kurrenti | 10A |
| Max. Pressjoni | 10 bar (145 psi) |
| Dijametru tal-pajp | 1 pulzier x 1 pulzier |
| Grad ta' Protezzjoni | IP65 |
| Max. Temperatura | 60°C |
| Piż tal-oġġett | 900 g |
| Dimensjonijiet tal-Prodott | 23 x 17 x 18.5 ċm |
| Materjal | Metall |
| Kulur | Fidda |
| Numru tal-Mudell | TWPS101 |
5. Setup u Installazzjoni
Proper installation is crucial for the safe and efficient operation of the pump control unit. It is highly recommended that installation be performed by a qualified professional.
Passi ta' Installazzjoni:
- Immuntar: Securely fasten the pump control unit to a stable, vertical surface using appropriate screws. Ensure the unit is mounted in a position where the electrical connections are easily accessible but protected from direct water spray.
- Konnessjonijiet tal-pajpijiet: Connect the pump's discharge pipe to the inlet of the control unit and the system's supply pipe to the outlet. Both connections are 1 inch in diameter. Use thread sealant tape (PTFE tape) to ensure watertight connections. Ensure the unit is installed with the inlet at the bottom and outlet at the top, as indicated by flow arrows if present.
- Wiring Elettriku:

Stampa 5.1: Wiring diagram illustrating the connections for power input and pump output. Note the requirement for a three-wire cable and proper fastening of all screws and cable entries.
- Provvista tal-Enerġija: Connect the main power supply (220-240V, 50/60Hz) to the designated input terminals. Use a three-wire cable with an outer diameter between 7.5mm and 8.5mm. Ensure the power source is protected by a suitable circuit breaker.
- Konnessjoni tal-Pompa: Connect the pump's power cable to the designated output terminals.
- Konnessjonijiet sikuri: Ensure all four screws on the terminal cover are securely fastened. The two cable fixing nuts must also be tightened to prevent cable movement and maintain IP65 integrity.
- L-ertjar: Ensure the unit and the pump are properly grounded to prevent electrical hazards.
- Imla Inizjali: Before starting the pump, ensure the pump and the suction line are fully primed with water to prevent dry running.
6. Istruzzjonijiet Operattivi
The Total Automatic Pump Control TWPS101 operates automatically once properly installed and powered.
Sekwenza ta' Operazzjoni:
- Qawwa Mixgħul: Once power is supplied to the unit, the Qawwa Mixgħul (green) indicator light will illuminate.
- Bidu Awtomatiku: When a tap or valve is opened, causing a pressure drop below the starting pressure (1.5 bar), the control unit will automatically start the pump. The Pompa Mixgħula (yellow) indicator light will illuminate.
- Waqfien Awtomatiku: When the tap or valve is closed, and water flow stops, the pressure in the system will rise. The control unit will automatically stop the pump after a few seconds, and the Pompa Mixgħula id-dawl se jintefa.
- Protezzjoni mit-tħaddim xott: If the pump runs without water (dry running), the control unit will detect the lack of flow and automatically stop the pump to prevent damage. The Nuqqas (red) indicator light will illuminate.
- Restarting After Failure: Jekk il- Nuqqas light is on, ensure there is water supply to the pump. Once the water supply is restored, press the Ibda mill-ġdid button on the control panel to reset the unit and resume normal operation.
7. Manutenzjoni
The Total Automatic Pump Control TWPS101 is designed for minimal maintenance. However, regular checks can help ensure its longevity and reliable performance.
- Spezzjoni regolari: Periodically inspect the unit for any signs of physical damage, leaks, or loose connections.
- Tindif: Żomm il-barra tal-unità nadifa u ħielsa mit-trab u l-fdalijiet. Uża drapp artab u nadif.amp drapp għat-tindif. Tużax tindif jew solventi li joborxu.
- Azzjoni tax-xitwa (jekk applikabbli): In areas prone to freezing temperatures, ensure the unit and connected pipes are drained or protected from frost to prevent damage.
- Konnessjonijiet elettriċi: Occasionally check that all electrical connections remain tight and secure.
8 Issolvi l-problemi
This section provides solutions to common issues you might encounter with your Total Automatic Pump Control.
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Failure (red) light is on. | No water supply to the pump (dry running). Pompa mhux ipprajmata. | Ensure water supply is available. Prime the pump and suction line. Press the Ibda mill-ġdid buttuna. |
| Il-pompa ma tixgħelx meta jinfetaħ il-vit. | Ebda enerġija għall-unità. Konnessjonijiet elettriċi sfużi. Problema bil-mutur tal-pompa. Unit in failure mode (red light on). | Check power supply and circuit breaker. Verify all electrical connections are secure. Check pump motor for faults. If red light is on, follow steps for 'Failure' light. |
| Il-pompa taħdem kontinwament. | Leak in the plumbing system. Pressure sensor malfunction. Constant water demand. | Check all pipes, fittings, and fixtures for leaks. If no leaks are found, the pressure sensor may be faulty and require professional inspection. Ensure no taps are left open. |
| Il-pompa tixgħel u tintefa ta' spiss. | Small leak in the system. Check valve issue. Fluss ta 'ilma insuffiċjenti. | Inspect for small leaks. Check the pump's check valve for proper operation. Ensure adequate water supply to the pump. |
If the problem persists after attempting these solutions, please contact a qualified technician or the manufacturer's support.
9. Informazzjoni dwar Garanzija
Specific warranty terms and conditions for the Total Automatic Pump Control TWPS101 are typically provided at the time of purchase or included with the product packaging. Please refer to your purchase receipt or the documentation supplied with your unit for detailed warranty coverage, duration, and claim procedures. Keep your proof of purchase in a safe place.
10. Appoġġ għall-Klijent
For technical assistance, spare parts, or further inquiries regarding your Total Automatic Pump Control TWPS101, please contact your retailer or the authorized Total service center in your region. When contacting support, please have your product model number (TWPS101) and purchase details ready.