1. Introduzzjoni

This manual provides instructions for the proper installation, operation, and maintenance of the Zurn 34-850TXL Lead-Free FNPT Tapped Ball Valve. This valve is designed for residential, commercial, and industrial applications, suitable for throttling and balancing low-pressure steam, air, water, and non-corrosive gas or oil systems.

Zurn 34-850TXL Lead-Free FNPT Tapped Ball Valve, front view

Figura 1: Quddiem view of the Zurn 34-850TXL Lead-Free FNPT Tapped Ball Valve.

2. Informazzjoni dwar is-Sigurtà

Read all instructions carefully before installation or operation. Failure to follow these instructions may result in property damage, personal injury, or death. Always wear appropriate personal protective equipment (PPE) during installation and maintenance.

  • Ensure the system is depressurized and drained before installing or servicing the valve.
  • Verify compatibility of the valve material with the fluid being handled.
  • Do not exceed the maximum pressure rating of the valve.
  • L-installazzjoni għandha titwettaq minn persunal kwalifikat skont il-kodiċijiet u r-regolamenti lokali.

3. Kontenut tal-Pakkett

The package should contain the following item:

  • One (1) Zurn 3/4" Tapped Ball Valve (Model 34-850TXL)

4. Speċifikazzjonijiet tal-Prodott

KaratteristikaDettall
Numru tal-Mudell34-850TXL
BrandZurn
MaterjalBrass, Bronze
Finish ta 'barraBronż
Daqs tal-Konnessjoni tad-Dħul0.75 Pulzier
Tip ta' Konnessjoni tad-DħulPort sħiħ
Daqs tal-Konnessjoni tal-Ħutlet0.75 Pulzier
Tip ta' Konnessjoni tal-ĦutFNPT (Female National Pipe Taper)
Numru ta' Portijiet2
Dimensjonijiet tal-Prodott (L x W x H)3 x 4 x 4 pulzieri
Piż tal-oġġett11.29 uqija
KonformitàLead-Free Compliant, Specification Met: Steam
Zurn 34-850TXL Ball Valve with model number visible

Figura 2: Ġenb view of the Zurn 34-850TXL valve, showing model markings.

5. Installazzjoni

Follow these steps for proper installation of the Zurn 34-850TXL ball valve:

  1. Preparazzjoni: Ensure the system is completely shut off, depressurized, and drained. Clean the pipe threads of any debris.
  2. Siġillant tal-Ħjut: Apply an appropriate thread sealant (e.g., PTFE tape or pipe dope) to the male pipe threads. Ensure the sealant is compatible with the system fluid and valve materials.
  3. Konnessjoni: Thread the valve onto the pipe. Use a wrench on the valve body flats to tighten. Tissikkax iżżejjed, as this can damage the valve or pipe threads. Avoid applying torque to the valve handle.
  4. Orjentazzjoni: The valve can be installed in any orientation. Ensure the handle has sufficient clearance for full quarter-turn operation.
  5. Tapped Port (if applicable): If utilizing the tapped port, ensure proper connection and sealing of any auxiliary devices (e.g., pressure gauges, drain valves).
  6. Istartjar tas-Sistema: Slowly repressurize the system and check for leaks at all connections.
Zurn 34-850TXL Ball Valve, showing FNPT inlet

Figura 3: View of the valve's FNPT inlet connection.

Zurn 34-850TXL Ball Valve, showing FNPT outlet

Figura 4: View of the valve's FNPT outlet connection.

6. Operazzjoni

The Zurn 34-850TXL is a quarter-turn ball valve, meaning it requires a 90-degree rotation of the handle to go from fully open to fully closed, or vice versa.

  • Biex Tiftaħ il-Valv: Rotate the handle until it is parallel with the pipeline. This indicates a full port opening, allowing maximum flow.
  • Biex Tagħlaq il-Valv: Rotate the handle until it is perpendicular to the pipeline. This indicates the valve is fully closed, stopping flow.
  • Throttling/Balancing: The valve can be partially opened to regulate flow. For precise balancing, specialized balancing valves may be more suitable.

7. Manutenzjoni

The Zurn 34-850TXL ball valve is designed for minimal maintenance. Regular inspection is recommended to ensure optimal performance.

  • Spezzjoni: Periodically check for any signs of leaks around the valve body or connections. Inspect the handle for damage or looseness.
  • Tindif: Keep the exterior of the valve clean. Avoid using harsh chemicals that could damage the bronze finish or internal components.
  • Lubrikazzjoni: The valve is designed with self-lubricating components and typically does not require external lubrication.
  • Tiswija: In case of persistent leaks or operational issues, it is recommended to replace the valve. Attempting to repair internal components may void any warranty and could compromise the valve's integrity.

8 Issolvi l-problemi

ProblemaKawża PossibbliSoluzzjoni
Tnixxija fil-konnessjonijiet tal-pajpijietImproper thread sealant, insufficient tightening, damaged threads.Depressurize system, reapply thread sealant, retighten connections. If threads are damaged, replace the valve or pipe section.
Leakage from valve body/stemInternal seal failure, manufacturing defect.Ibdel il-valv.
Valv diffiċli biex iddawwarDebris inside valve, worn internal components, corrosion.Attempt to cycle the valve several times. If resistance persists, replace the valve.
Incomplete shut-offDebris preventing full closure, worn ball or seats.Ibdel il-valv.

9. Garanzija u Appoġġ

For specific warranty information and technical support regarding your Zurn 34-850TXL Lead-Free FNPT Tapped Ball Valve, please refer to the official Zurn website or contact Zurn customer service directly. Keep your purchase receipt for warranty claims.

Manifattur: Zurn Industries

Websit: www.zurn.com (Eżampil-link, il-link attwali jista' jvarja)

Dokumenti Relatati - 34-850TXL

Preview Zurn NR3XL Water Pressure Reducing Valve with Integral By-Pass Check Valve and Strainer
Detailed specifications and installation guide for the Zurn NR3XL, a water pressure reducing valve designed for potable water lines. Features include an integral strainer, by-pass check valve, and low lead cast bronze body. Suitable for residential and commercial applications.
Preview Valv tat-Tnaqqis tal-Pressjoni Zurn NR3XL mingħajr Ċomb: Gwida għall-Installazzjoni, Manutenzjoni u Tiswija
Gwida komprensiva għall-Valv tat-Tnaqqis tal-Pressjoni mingħajr Ċomb Zurn NR3XL, li tkopri l-installazzjoni, l-ispezzjoni, il-manutenzjoni, il-proċeduri ta' tiswija, u s-soluzzjoni tal-problemi. Tinkludi l-ispeċifikazzjonijiet tal-prodott u informazzjoni dwar il-garanzija.
Preview Assemblaġġ tal-Valv li Jnaqqas il-Pressjoni Zurn Wilkins ZW209FP: Installazzjoni, Tħaddim, u Manutenzjoni
Gwida komprensiva għall-assemblaġġ tal-valv li jnaqqas il-pressjoni tal-protezzjoni min-nar Zurn Wilkins ZW209FP, li tkopri l-installazzjoni, il-bidu, it-tħaddim, il-karatteristiċi tal-fluss, u l-proċeduri ta' manutenzjoni. Tinkludi struzzjonijiet dettaljati għall-valv prinċipali u l-valv pilota PV-PRD.
Preview Assemblaġġ tal-Valv ta' Iċċekkjar Doppju ZURN Mudell 350AST: Speċifikazzjonijiet u Applikazzjoni
Dettalji tekniċi komprensivi għall-Mudell 350AST Double Check Valve tal-ZURN, li jkopru l-applikazzjoni tiegħu f'sistemi tal-ilma tax-xorb, materjali, standards ta' konformità, dimensjonijiet, piżijiet, karatteristiċi tal-fluss, u linji gwida għall-installazzjoni.
Preview Zurn AquaSense ZER-SM Series Automatic Battery-Powered Flush Valve Manual
Comprehensive manual for Zurn AquaSense ZER-SM series automatic battery-powered flush valves, covering installation, operation, maintenance, troubleshooting, and parts breakdown for models like ZER6000-SM, ZER6200-SM, ZER6003-SM, and ZER6203-SM.
Preview ZURN Model AG Air Gap Adaptor Fitting
The ZURN Model AG Air Gap Adaptor Fitting is designed for use with ZURN WILKINS Reduced Pressure Principle Backflow Preventers, ensuring proper drain line installation on horizontal or vertical systems. This document details its specifications, materials, and typical installation requirements.