ProCom ML1PHG

ProCom ML1PHG Ventless Propane Gas Infrared Space Heater User Manual

Model: ML1PHG

Introduzzjoni

This manual provides essential information for the safe and efficient operation of your ProCom ML1PHG Ventless Propane Gas Infrared Space Heater. Please read all instructions carefully before installation and use. This heater is designed to provide supplemental heat for indoor residential spaces.

ProCom ML1PHG Ventless Propane Gas Infrared Space Heater, front view.

Figure 1: ProCom ML1PHG Ventless Propane Gas Infrared Space Heater, front view.

Informazzjoni dwar is-Sigurtà

Is-sigurtà tiegħek u s-sigurtà ta’ ħaddieħor huma importanti ħafna. Dan il-manwal fih messaġġi importanti dwar is-sigurtà. Dejjem aqra u obdi l-messaġġi kollha dwar is-sigurtà.

Kontenut tal-Pakkett

Iċċekkja li l-komponenti kollha huma preżenti qabel tibda l-installazzjoni.

Setup u Installazzjoni

The ProCom ML1PHG heater can be wall-mounted using the included bracket or placed on a floor with optional base feet (sold separately).

Immuntar tal-ħajt

  1. Select a suitable wall location, ensuring it is away from combustible materials and has proper clearances.
  2. Attach the wall mounting bracket securely to the wall using the provided hardware. Ensure the bracket is level and firmly anchored to wall studs or appropriate anchors.
  3. Carefully lift the heater and align the mounting slots on the back of the heater with the bracket. Lower the heater onto the bracket until it is securely seated.
ProCom ML1PHG Heater mounted on a wall in a living room

Figura 2: Eżample of the heater mounted on a wall.

Konnessjoni tal-Gass

This heater operates on Liquid Propane (LP) gas only. A qualified technician must perform the gas connection.

Close-up of the LP gas connection point on the heater

Figura 3: Close-up view of the Liquid Propane (LP) gas connection point.

Istruzzjonijiet Operattivi

The ML1PHG heater features a manual control for simple operation.

Proċedura ta' Tqabbid

  1. Kun żgur li l-valv tal-provvista tal-gass għall-heater ikun miftuħ.
  2. Locate the control knob on the top of the heater.
  3. Push the control knob in and turn it counter-clockwise to the PILOT/IGN pożizzjoni.
  4. While holding the knob in, repeatedly press the INDIKATUR button until the pilot flame ignites. You should see a small blue flame.
  5. Kompli żomm il-pum tal-kontroll magħfus għal madwar 30-60 sekonda wara li l-pilota jixgħel biex tħalli t-termokoppja tisħon.
  6. Release the control knob. The pilot flame should remain lit. If it extinguishes, repeat steps 3-5.
  7. Once the pilot is lit, push the control knob in slightly and turn it counter-clockwise to the desired heat setting: BAXXA or GĦOLJA. The main burner will ignite.
Close-up of the control knob with Ignitor button, Pilot/Ign, Off, Low, and High settings

Figure 4: Control knob and ignitor button for operation.

Close-up of the radiant ceramic plaques glowing red when operating

Figure 5: The radiant ceramic plaques will glow red during operation.

Shutting Down the Heater

Manutenzjoni

Manutenzjoni regolari tiżgura l-lonġevità u t-tħaddim sikur tal-ħiter tiegħek.

Issolvi l-problemi

Irreferi għat-tabella li ġejja għal kwistjonijiet komuni u s-soluzzjonijiet tagħhom.

ProblemaKawża PossibbliSoluzzjoni
Il-pilota mhux se jixgħelNo gas supply; Air in gas line; Pilot orifice clogged; Thermocouple faulty; ODS activated.Ensure gas supply is on; Bleed air from line; Clean pilot orifice; Replace thermocouple; Check ventilation.
Pilot lights but main burner will not igniteControl knob not held long enough; Low gas pressure; Main burner orifice clogged.Hold knob for 30-60 seconds; Check gas supply pressure; Clean main burner orifice.
Heater produces odorNew heater burn-off; Dust accumulation; Inadequate ventilation.Operate for a few hours in a well-ventilated area; Clean heater; Increase ventilation.
Il-heater jintefa bla mistenniODS activation (low oxygen); Pilot flame extinguished; Gas supply interrupted.Ensure adequate ventilation; Relight pilot; Check gas supply.

Jekk il-passi għas-soluzzjoni tal-problemi ma jsolvux il-problema, ikkuntattja tekniku tas-servizz kwalifikat.

Speċifikazzjonijiet

KaratteristikaDettall
BrandProCom
Numru tal-MudellML1PHG
Tip ta' FjuwilGass Propan Biss
Maximum BTU Output10,000 BTU
Kopertura tat-TisħinSa 500 Sq. Ft.
Tip ta' KontrollManual (On/Off Settings)
Sistema ta 'TqabbidPush Button Piezo Ignition
Karatteristiċi tas-SigurtàOxygen Depletion Sensor (ODS) with automatic shut-off
Elettriku MeħtieġNru
Dimensjonijiet tal-Prodott (H x W x D)18.5" Għoli x 24" Wisa' x 8" Fond
Piż tal-Prodott13 lbs.
Tip ta 'ImmuntarImmuntar mal-ħajt (ħardwer inkluż)
UPC848660004002
Diagram showing dimensions of the ProCom ML1PHG heater: 18.5 inches high, 24 inches wide, 8 inches deep.

Figure 6: Product dimensions of the ProCom ML1PHG heater.

Informazzjoni dwar Garanzija

This ProCom ML1PHG Ventless Propane Gas Infrared Space Heater comes with a Garanzija Limitata ta' Sena from the date of purchase. This warranty covers defects in materials and workmanship under normal use and service. For full warranty details and to make a claim, please refer to the documentation included with your product or contact ProCom customer support.

Appoġġ għall-Klijent

For technical assistance, parts, or service inquiries, please contact ProCom customer support. Have your model number (ML1PHG) and purchase date available when contacting support.

Note: Contact information for ProCom is not provided in the product data. Please refer to the manufacturer's official website or product packaging for direct support channels.

Dokumenti Relatati - ML1PHG

Preview Manwal tal-Utent tar-Radju 2-Way tal-Banda taċ-Ċittadini Procom PRO-9900 AM/FM ĠDID
Manwal tal-utent għar-Radju 2-Way Procom NEW PRO-9900 AM/FM Citizens Band, li jiddeskrivi l-funzjonijiet, l-operazzjonijiet, il-karatteristiċi u l-ispeċifikazzjonijiet tekniċi tiegħu għal użu ottimali.
Preview PROCOM Atlas Loud Mouth Digital Wireless Intercom User Manual
This user manual provides comprehensive information on the PROCOM Atlas Loud Mouth Digital Wireless Intercom, including its features, operation, specifications, safety guidelines, and FCC compliance.
Preview ProCom Heating Vent-Free Gas Space Heater: Operation and Installation Manual
Comprehensive guide for ProCom Heating vent-free gas space heaters, covering installation, operation, safety, maintenance, and troubleshooting for models MN180TPA-B, ML150TPA-B, MN300TPA-B, and ML250TPA-B.
Preview Manwal tas-Sid għat-Tħaddim u l-Installazzjoni tal-Heater tal-Ħajt tal-Gass mingħajr Vent ProCom
Dan il-manwal jipprovdi struzzjonijiet dwar it-tħaddim u l-installazzjoni għall-ProCom Vent-Free Gas Wall Heaters, inklużi l-mudelli MN2PHG, MN2PTG, MN3PHG, MN3PTG, ML2PHG, ML2PTG, ML3PHG, u ML3PTG. Ikopri l-prekawzjonijiet ta' sigurtà, il-karatteristiċi tal-prodott, l-ispeċifikazzjonijiet, il-proċeduri ta' installazzjoni, it-tħaddim, is-soluzzjoni tal-problemi, il-partijiet, l-aċċessorji, u informazzjoni dwar il-garanzija.
Preview Manwal tal-Heater tal-Log tal-Gass mingħajr Ventilazzjoni ProCom Heating
Dan il-manwal jipprovdi struzzjonijiet komprensivi dwar l-installazzjoni, it-tħaddim, is-sigurtà u l-manutenzjoni għall-mudelli ProCom Heating Vent-Free Gas Log Heater PCNSD18T, PCNSD24TD, u PCNSD24M. Tgħallem kif tinstalla u tuża l-gas log heater tiegħek b'mod sigur.
Preview ProCom Heating QNSD250T Vent-Free Gas Stove Owner's Operation and Installation Manual
Detailed owner's operation and installation manual for the ProCom Heating QNSD250T Vent-Free Gas Stove, covering safety, specifications, installation, operation, maintenance, and troubleshooting.