PerfectPrime TC0521

PerfectPrime TC0521 4-Channel Thermocouple Thermometer User Manual

Mudell: TC0521

1. Introduzzjoni

Thank you for choosing the PerfectPrime TC0521 4-Channel Thermocouple Thermometer. This instrument is designed for precise temperature measurement across multiple points simultaneously, supporting K, J, E, T, N, R, and S type thermocouples. It features data logging capabilities, USB PC connectivity, and wireless mobile app integration for convenient monitoring and analysis. This manual provides essential information for the safe and efficient operation of your device.

2. Prodott Aktarview

Karatteristiċi Ewlenin

  • Four Channels Thermocouple Thermometer supporting K, J, E, T, N, R, S Type.
  • 3.35" LCD display for clear readings.
  • Internal DataLog Storage: 32,000 data logger records per channel.
  • USB PC Interface: Real-time monitoring, graphic display, data logging, storage, and data import/export.
  • Wireless connectivity to mobile apps (iOS and Android).
  • Fast response and samprata tal-linarda.
  • Adjustable auto power-off timer.
  • Temperature alarm function.
  • Instant recall function for stored data.

Identifikazzjoni tal-Komponent

PerfectPrime TC0521 Thermometer front view
Quddiem view of the PerfectPrime TC0521 Thermometer, showing the LCD display and control buttons.
PerfectPrime TC0521 Thermometer top view with probe inputs
Fuq view of the PerfectPrime TC0521, highlighting the four thermocouple input ports (T1, T2, T3, T4).
PerfectPrime TC0521 Thermometer side view bil-port tal-USB
Ġenb view of the PerfectPrime TC0521, showing the micro USB port for PC connectivity.

3. Setup

3.1 Installazzjoni tal-batterija

  1. Sib il-kompartiment tal-batterija fuq wara tal-apparat.
  2. Iftaħ l-għatu tal-batterija.
  3. Daħħal żewġ batteriji AAA ta' 1.5V, waqt li tiżgura l-polarità korretta.
  4. Agħlaq l-għatu tal-batterija sew.

3.2 Konnessjoni tas-Sonda tat-Termokoppja

  1. Identify the four input ports (T1, T2, T3, T4) at the top of the thermometer.
  2. Connect the K-type bead probes (or other compatible thermocouple types) to the desired input ports. Ensure the positive (+) and negative (-) terminals of the probe connector align with the corresponding markings on the thermometer.
  3. For accurate readings, ensure the probes are securely inserted.
K-type bead probes
Included K-type bead probes, ready for connection to the thermometer.

3.3 Software and Mobile App Installation

  • Softwer tal-PC: Download the Windows software (compatible with XP/Vista/7/8/10) from the manufacturer's websit. Segwi l-istruzzjonijiet fuq l-iskrin għall-installazzjoni.
  • App mobbli: Fittex għal the PerfectPrime mobile app on the iOS App Store or Android Play Store. Install the app and follow the in-app instructions to connect wirelessly via Bluetooth.

4. Istruzzjonijiet Operattivi

4.1 Power On/Off

  • Agħfas il- Qawwa buttuna biex tixgħel it-termometru.
  • Agħfas u żomm il- Qawwa button again to turn the thermometer off.
  • The device features an adjustable auto power-off timer to conserve battery life.

4.2 Kejl Bażiku tat-Temperatura

  1. Ensure probes are correctly connected to the input ports.
  2. Power on the device. The display will show temperature readings for each active channel.
  3. Place the probe tips at the desired measurement points. Allow a few moments for the readings to stabilize.

4.3 Għażla tal-Unità (°C/°F)

  • Agħfas il- UNITÀ buttuna biex taqleb bejn l-unitajiet tat-temperatura Celsius (°C) u Fahrenheit (°F).

4.4 Funzjoni ta' Żamma tad-Data

  • Agħfas il- ŻOMM button to freeze the current temperature readings on the display.
  • Agħfas il- ŻOMM button again to release the hold and resume live readings.

4.5 Min/Max/Avg Functions

  • Agħfas il- MAX button to display the maximum temperature recorded since the device was powered on or the function was reset.
  • Agħfas il- MIN button to display the minimum temperature recorded.
  • Agħfas il- AVG button to display the average temperature recorded.
  • To reset these values, typically a long press of the respective button or a specific sequence might be required (refer to the included mini-manual for exact steps).

4.6 Dawl ta 'wara

  • Agħfas il- Dawl ta' wara button (often represented by a light bulb icon) to turn the display backlight on or off for improved visibility in low-light conditions.

4.7 Data Logging and Wireless Connectivity

  • The device can store up to 32,000 data records per channel internally.
  • Connect the thermometer to a PC via the micro USB cable or wirelessly to your mobile device via Bluetooth.
  • Use the dedicated PC software or mobile app to configure data logging intervals, view real-time data, analyze trends, and export recorded data.
Video demonstrating the unboxing and connection of K-type thermocouple probes to a similar digital thermometer. This illustrates the physical setup process.
Video providing a general overview of a digital thermocouple thermometer, showcasing its display and basic operation.

5. Manutenzjoni

  • Tindif: Imsaħ l-apparat b'ċarruta ratba u niexfa. Tużax prodotti tat-tindif jew solventi li joborxu.
  • Sostituzzjoni tal-batterija: Replace batteries when the low battery indicator appears on the display to ensure continuous operation.
  • Ħażna: Store the thermometer in a cool, dry place away from direct sunlight and extreme temperatures when not in use. Remove batteries if storing for extended periods.
  • Kura tas-Sonda: Handle thermocouple probes carefully. Avoid bending or kinking the wires excessively. Replace damaged probes to maintain accuracy.

6 Issolvi l-problemi

  • Ebda Qawwa: Iċċekkja l-installazzjoni tal-batterija u kun żgur li l-batteriji huma friski.
  • Qari mhux eżatt: Verify probe connections, ensure the correct thermocouple type is selected (if applicable), and check for damaged probes. Allow sufficient time for readings to stabilize.
  • Kwistjonijiet ta' Konnettività: For PC connection, ensure the USB cable is properly connected and drivers are installed. For mobile app, ensure Bluetooth is enabled on both devices and the app is correctly paired.
  • Żbalji fil-Wiri: If the display shows '----' or other error messages, check probe connections and ensure the measured temperature is within the device's specified range.

7. Speċifikazzjonijiet

KaratteristikaSpeċifikazzjoni
Measurement Temperature Range (K-type)-200°C sa 1372°C (-328°F sa 2501°F)
Measurement Temperature Range (J-type)-200°C sa 1000°C (-328°F sa 1832°F)
Measurement Temperature Range (E-type)-200°C sa 750°C (-328°F sa 1382°F)
Measurement Temperature Range (T-type)-200°C sa 400°C (-328°F sa 752°F)
Accuracy (J, K, E, T, N-type)±(0.1% of reading + 0.7°C) above -100°C; ±(0.5% of reading + 0.7°C) below -100°C
Accuracy (R, S-type)±(0.2% tal-qari + 1.4°C)
Temperature Resolution (K, J, E, T, N-type)0.1°C (<600°C), 1°C (≥600°C)
Temperature Resolution (R, S-type)0.2°C (<600°C), 1°C (≥600°C)
Sample Rata2 darbiet kull sekonda
Tip ta 'batterija4 x batteriji AAA 1.5V
Battery Lifetime (Bluetooth OFF)Appross. 120 sigħat (batterija alkalina)
Battery Lifetime (Bluetooth ON)Appross. 30 sigħat (batterija alkalina)
Temperatura ta' Operazzjoni0°C sa 50°C (32°F sa 122°F)
Operazzjoni Umdità10 sa 90% RH (mingħajr kondensazzjoni)
Temperatura tal-Ħażna-20°C sa 60°C (-4°F sa 140°F)
Umdità tal-Ħażna10 sa 75% RH
Dimensjonijiet187mm (L) × 75mm (W) × 29mm (H)
PiżAppross. 290g
Tip ta 'WiriLCD
Teknoloġija tal-KonnettivitàUSB, Bluetooth
Materjal ta 'barraPolikarbonat (PC)

8. X'hemm fil-Kaxxa

  • PerfectPrime TC0521 Thermocouple Thermometer
  • Manwal ta 'Istruzzjoni (dan id-dokument)
  • AAA 1.5V batteries (4 pcs)
  • Kejbil mikro USB
  • K-type bead probes (2 pcs)
  • Windows software (available for download)

9. Garanzija u Appoġġ

While specific standard warranty details are not provided in the product information, PerfectPrime is committed to product quality. An optional 1-Year Extended Warranty Plan by Onsitego is available for purchase. For technical support, troubleshooting assistance, or warranty inquiries, please refer to the contact information provided with your purchase or visit the official PerfectPrime websit.

This device has a Certificate of Calibration from the National Measurement Laboratory R.O.C (NML/ROC) and is Made in Taiwan, ensuring quality and reliability.

Dokumenti Relatati - TC0521

Preview PerfectPrime TC0580 Thermocouple Temperature Data Logger Instruction Manual
This instruction manual provides comprehensive guidance on the PerfectPrime TC0580 Thermocouple Temperature Data Logger. It covers product features, specifications, software installation, device operation, data logging, viewing, exporting, and troubleshooting.
Preview Gwida tal-Protokoll tal-Interfaċċja USB PerfectPrime TC0520
Gwida komprensiva għall-protokoll tal-interfaċċja USB għat-termometru tad-datalogger PerfectPrime TC0520, li tiddeskrivi fid-dettall il-kmandi, l-output tad-dejta, u l-iċċekkjar tal-iżbalji.
Preview PerfectPrime AR168 Digital Pressure Gauge Istruzzjoni Manwal
Manwal ta' struzzjonijiet għall-Gauge tal-Pressjoni Diġitali PerfectPrime AR168, li jkopri l-introduzzjoni tal-prodott, il-funzjonijiet bażiċi, il-prestazzjoni teknika, il-firxiet tal-kejl, id-definizzjonijiet tas-simboli, l-operazzjonijiet tal-buttuni, il-prekawzjonijiet, u informazzjoni addizzjonali.