Real Flame C539LP-SHL

Real Flame Riverside 36" Shale Propane/Natural Gas Fire Pit Instruction Manual

Model: C539LP-SHL | Brand: Real Flame

Informazzjoni Importanti dwar is-Sigurtà

TWISSIJA: For outdoor use only. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment.

This fire pit is designed for use with either Liquid Propane (LP) gas or Natural Gas (NG). Conversion to Natural Gas must be performed by a Certified Gas Technician. An external gas line is required for connection to a natural gas source.

Propożizzjoni 65 Twissija: Dan il-prodott jista’ jesponik għal kimiċi inkluż il-monossidu tal-karbonju, li huwa magħruf mill-Istat ta’ Kalifornja li jikkawża difetti fit-twelid jew ħsara riproduttiva oħra. Għal aktar informazzjoni mur fuq www.P65Warnings.ca.gov.

Prodott Overview

The Real Flame Riverside Gas Fire Bowl is a durable, fiber-cast concrete fire pit designed to enhance outdoor spaces. It features a 50,000 BTU stainless steel burner and electronic push-button ignition for ease of use. This model includes a natural gas conversion kit, allowing flexibility in fuel type.

  • Materjal: Fiber-cast concrete (Stone finish)
  • Output tas-Sħana: 50,000 BTUs
  • Tqabbid: Battery-operated electronic push-button
  • Tip ta' Fjuwil: Liquid Propane (LP) or Natural Gas (NG) with included conversion kit
  • Aċċessorji inklużi: 8-inch LP hose and regulator, lava rock filler, tank seat, protective cover.
Real Flame Riverside Fire Pit in an outdoor setting with flames

Image: The Riverside Fire Pit in an outdoor patio setting, showcasing its design and active flame.

Setup Istruzzjonijiet

  1. Spakkjar: Neħħi l-komponenti kollha mill-imballaġġ bir-reqqa. Iċċekkja għal kwalunkwe ħsara.
  2. Pjazzament: Position the fire pit on a level, non-combustible surface outdoors, away from any flammable materials or structures. Ensure adequate clearance as specified in the full safety manual.
  3. Lava Rock Placement: Distribute the provided lava rock evenly over the burner pan, ensuring not to block the ignition electrode or burner holes.
  4. Close-up of lava rock and burner in the fire pit

    Immaġni: Close-up view of the lava rock distributed around the stainless steel burner ring.

  5. LP Gas Connection (Propane):
    • Place the LP tank on the included tank seat.
    • Connect the 8-inch LP hose and regulator to the LP tank valve. Hand-tighten securely.
    • Ensure all connections are tight before proceeding.
  6. Natural Gas Conversion (Optional):
    • Din il-konverżjoni GĦANDU be performed by a certified gas technician.
    • The included Natural Gas conversion kit contains the necessary components.
    • An external gas line is required for connection to a natural gas source.
  7. Natural Gas conversion kit components

    Image: Components of the Natural Gas conversion kit, including hose and fittings.

  8. Installazzjoni tal-batterija: Install one AAA battery (not included) into the electronic ignition module.
Wara view of Real Flame Riverside Fire Pit showing control panel and LP hose connection

Immaġni: Wara view of the fire pit, highlighting the control panel and the connected LP gas hose and regulator.

Istruzzjonijiet Operattivi

  1. Qabel id-Dawl: Ensure the gas supply valve is open (for LP tank) or the main gas line is on (for NG).
  2. Tixgħel il-Fuq tan-Nar:
    • Locate the control knob on the side of the fire pit.
    • Push and hold the control knob in, then turn it counter-clockwise to the "LOW" position.
    • While holding the knob in, press the electronic igniter button repeatedly until the burner ignites. You should hear a clicking sound and see the flame.
    • Once ignited, continue to hold the control knob in for 10-15 seconds to allow the thermocouple to heat up and engage.
    • Release the control knob. If the flame extinguishes, repeat the lighting process.
  3. Aġġustament tal-Fjamma: Once lit, turn the control knob to adjust the flame height from "LOW" to "HIGH" as desired.
  4. Tfigħ:
    • Dawwar il-pum tal-kontroll lejn l-arloġġ għall-pożizzjoni "MITFI".
    • Close the gas supply valve on the LP tank or turn off the main gas line for NG.
    • Allow the fire pit to cool completely before covering or moving.

Manutenzjoni

  • Tindif: Clean the exterior surfaces with a soft cloth and mild soap. Do not use abrasive cleaners.
  • Blat tal-lava: Periodically inspect lava rock for debris or blockages. Replace if significantly deteriorated.
  • Qoxra Protettiva: Use the included protective cover when the fire pit is not in use to shield it from weather elements.
  • Konnessjonijiet tal-gass: Regularly check all gas connections and hoses for leaks or damage. Perform a leak test with soapy water if a gas odor is detected.
  • Burner: Keep the burner ports clear of insects and debris.

Issolvi l-problemi

ProblemaKawża PossibbliSoluzzjoni
Il-berner ma jixgħelx
  • Provvista tal-gass mitfija
  • Igniter battery dead or incorrectly installed
  • Arja fil-linja tal-gass
  • Portijiet tal-berner imblukkati
  • Iftaħ il-valv tal-provvista tal-gass
  • Replace battery, ensure correct polarity
  • Purge air by attempting to light several times
  • Naddaf il-portijiet tal-burner
Fjamma baxxa jew teptip
  • Pressjoni baxxa tal-gass
  • Partially blocked burner ports
  • Riħ eċċessiv
  • Check LP tank level or NG supply
  • Naddaf il-portijiet tal-burner
  • Relocate fire pit or use wind guard (if available)
Il-fjamma tintefa wara li tinħelesasing knob
  • Thermocouple not heated
  • Termokoppja difettuż
  • Hold knob in longer (10-15 seconds)
  • Contact a certified technician for inspection/replacement

Speċifikazzjonijiet

  • Numru tal-Mudell: C539LP-SHL
  • Ditta: Fjamma vera
  • Materjal: Fiber-cast Concrete (Stone)
  • Dimensjonijiet tal-Prodott: 36.25"D x 36.25"W x 13"H
  • Forma: Round
  • Tip ta 'Finish: Miżbugħa
  • Piż tal-oġġett: 99 Liri
  • Tip ta' Fjuwil: Propan Likwidu (LP) jew Gass Naturali (NG)
  • Output tas-Sħana: 50,000 BTUs
  • Kulur: Shale
  • UPC: 752370053925
Real Flame Riverside Fire Pit with dimensions labeled

Immaġni: Minn fuq view of the fire pit with its diameter and height dimensions indicated.

Garanzija u Appoġġ

For detailed warranty information, product registration, or technical support, please refer to the documentation included with your product or visit the official Real Flame websit. Żomm l-irċevuta tax-xiri tiegħek għal pretensjonijiet ta' garanzija.

Manifattur: Fjamma vera

Dokumenti Relatati - C539LP-SHL

Preview Nar tal-Gass Real Flame Serje Magiglo: Manwal tal-Installazzjoni u t-Tħaddim
Manwal komprensiv għall-installazzjoni u t-tħaddim tal-fireplaces tal-gass Real Flame Magiglo Series (Mudelli 320 & 360). Ikopri s-sigurtà, it-tipi ta' installazzjoni, id-dawl, l-ikkummissjonar, is-soluzzjoni tal-problemi, u informazzjoni dwar il-garanzija.
Preview Manwal tas-Sid u Gwida tas-Sigurtà tal-Mejda tan-Nar Rettangolari Real Flame Coden 2050LP
Manwal komprensiv tas-sid għar-Real Flame Coden Rectangle Fire Table (Mudell 2050LP). Jinkludi struzzjonijiet ta' sigurtà, gwida tal-assemblaġġ, tħaddim, kura, u pariri għas-soluzzjoni tal-problemi għal dan il-ħofra tan-nar tal-propan ta' barra.
Preview Manwal tas-Sid tal-Mejda tan-Nar Kwadra Casual 141NG Estes
Manwal tas-sid għall-141NG Estes Casual Square Fire Table minn Real Flame, li jiddeskrivi s-sigurtà, l-installazzjoni, it-tħaddim, il-manutenzjoni, u s-soluzzjoni tal-problemi għall-użu fuq barra.
Preview Real Flame Natural Gas Conversion Kit Manual - Convert LP Fireplace to NG
This manual provides instructions for converting Real Flame LP gas fireplaces to natural gas (NG). It includes a parts list, detailed conversion steps, safety warnings, specifications, lighting procedures, warranty information, and return policies.
Preview Manwal tas-Sid tal-Mejda tan-Nar Rettangolari Jensen Co 13045LP
Manwal uffiċjali tas-sid għall-Jensen Co 13045LP Rectangle Fire Table minn Real Flame. Fih twissijiet essenzjali ta' sigurtà, passi ta' assemblaġġ, struzzjonijiet ta' tħaddim, pariri dwar il-kura u t-tindif, gwida għas-soluzzjoni tal-problemi, garanzija, u politika ta' ritorn għall-fuklar tal-gass LP ta' barra tiegħek.
Preview Real Flame Natural Gas Conversion Kit Manual for 1582LP Fireplace
This manual provides instructions for converting a Real Flame LP gas fireplace to operate on natural gas (NG). It is designed for use with the Jensen 1582LP fireplace model and kit #00023106U/U0002-06, covering installation, safety, and operation.