1. Prodott Aktarview
The Clivet Cristal Dual Split Air Conditioner system is designed to provide efficient cooling and heating for two separate indoor areas using a single outdoor unit. This model features Inverter technology for energy efficiency and includes Wi-Fi connectivity for smart control. The indoor units are designed with a modern, flat, and linear aesthetic with soft curves, making them suitable for various interior designs.
Key features include a high-density filter to capture fine dust and a cold catalyst filter to retain volatile organic compounds and odors, ensuring cleaner air quality.

This image displays the complete Clivet Cristal Dual Split Air Conditioner system. It features two sleek, white indoor units, typically mounted on a wall, and a single, compact outdoor condenser unit with a protective grille over its fan. The Clivet logo is visible on all components.
2. Informazzjoni dwar is-Sigurtà
Read all instructions carefully before installation and operation. Failure to follow these instructions may result in property damage, personal injury, or death.
- Installazzjoni professjonali: Installation, maintenance, and repair must be performed by qualified service personnel.
- Sigurtà Elettrika: Ensure the power supply matches the unit's requirements. Do not use damaged power cords or plugs. Always disconnect power before cleaning or servicing.
- Refriġerant: This unit contains refrigerant. Do not attempt to service the refrigerant circuit yourself.
- Ventilazzjoni: Aċċerta ruħek li jkun hemm ventilazzjoni xierqa madwar l-unità ta' barra.
- Tfal u Pets: Żomm it-tfal u l-annimali domestiċi 'l bogħod mill-unità waqt it-tħaddim u l-manutenzjoni.
- Materjali li jaqbdu: Tpoġġix materjali fjammabbli ħdejn l-unità.
3. Kontenut tal-Pakkett
Your Clivet Cristal Dual Split Air Conditioner package typically includes:
- Two (2) Clivet Cristal Indoor Units (12000 BTU each)
- One (1) Clivet Outdoor Unit (5.4 kW)
- Two (2) Remote Controls
- Manwal għall-Utent u Gwida għall-Installazzjoni
- Mounting Brackets and Accessories (may vary by package)
4. Setup u Installazzjoni
Installation of a split air conditioning system requires specialized tools and knowledge. It is strongly recommended that installation be performed by a certified HVAC professional to ensure proper functioning, safety, and compliance with local regulations.
Key Installation Steps (Overview għall-Professjonist):
- Għażla tas-Sit: Choose appropriate locations for both indoor and outdoor units, considering air circulation, drainage, and structural support.
- Mounting Indoor Units: Securely mount indoor units on the wall, ensuring they are level.
- Mounting Outdoor Unit: Install the outdoor unit on a stable, level surface or wall bracket, ensuring adequate clearance for airflow.
- Pajpijiet tar-refriġerant: Connect the refrigerant lines between the indoor and outdoor units. Ensure proper flaring and leak testing.
- Drenaġġ: Install condensate drain lines for indoor units, ensuring proper slope for water flow.
- Wiring Elettriku: Connect the power supply and communication wiring according to the wiring diagram provided in the detailed installation manual.
- Vacuum cleaner u Iċċarġjar: Evacuate the refrigerant lines to remove air and moisture, then charge the system with the correct amount of refrigerant if necessary.
- Test Run: Perform a test run to verify proper operation, check for leaks, and confirm cooling/heating performance.
5. Istruzzjonijiet Operattivi
The Clivet Cristal system can be operated via the included remote control or through a Wi-Fi enabled smart device.
Operazzjoni tal-Kontroll mill-bogħod:
- Power On/Off: Agħfas il- ON/OFF buttuna biex tibda jew twaqqaf l-unità.
- Għażla tal-Modalità: Uża l- MODALITÀ buttuna biex tiċċaqlaq bejn il-modi operattivi:
- Kessaħ: Għat-tkessiħ tal-kamra.
- Sħana: For heating the room (heat pump models).
- Fann: Jiċċirkola l-arja mingħajr tkessiħ jew tisħin.
- Nixxef: Jiddeumidifika l-arja.
- Auto: Automatically selects mode based on room temperature.
- Aġġustament tat-temperatura: Uża l- TEMP UP/DOWN buttuni biex tissettja t-temperatura mixtieqa.
- Veloċità tal-fann: Adjust fan speed using the FAN button (Auto, Low, Medium, High).
- Funzjoni Swing: Attiva l- SWING button for automatic louver movement.
- Funzjoni Timer: Set the unit to turn on or off automatically after a set period. Refer to the remote control manual for detailed timer settings.
Konnettività Wi-Fi:
The Wi-Fi feature allows you to control your air conditioner remotely via a smartphone application. Download the official Clivet app from your device's app store and follow the in-app instructions for pairing your unit. This typically involves connecting the unit to your home Wi-Fi network.
6. Manutenzjoni
Manutenzjoni regolari tiżgura prestazzjoni ottimali u testendi l-ħajja tal-arja kondizzjonata tiegħek. Dejjem skonnettja l-provvista tal-enerġija qabel ma tagħmel kwalunkwe manutenzjoni.
Manutenzjoni tal-Unità ta' Ġewwa:
- Tindif tal-filtru tal-arja:
- Iftaħ il-pannell ta 'quddiem tal-unità ta' ġewwa.
- Neħħi l-filtri tal-arja.
- Naddaf il-filtri b'vacuum cleaner jew aħsilhom b'ilma fietel u deterġent ħafif.
- Laħlaħ sewwa u ħallih jinxef kompletament bl-arja qabel ma terġa' ddaħħalh.
- Naddaf il-filtri kull ġimagħtejn jew aktar ta’ spiss skont l-użu u l-kwalità tal-arja.
- Tindif tal-Wiċċ tal-Unità: Imsaħ il-wiċċ tal-unità ta' ġewwa b'ċarruta ratba u damp drapp. Tużax kimiċi ħarxa jew tindif li joborxu.
Manutenzjoni tal-Unità ta' Barra:
- Tindif tal-Kojl: Periodically check the outdoor unit's coils for dirt and debris. Gently clean with a soft brush or water hose.
- Ostruzzjonijiet ċari: Ensure no leaves, branches, or other debris are blocking the airflow around the outdoor unit.
- Kontroll Professjonali: It is recommended to have a qualified technician perform an annual professional check-up and cleaning of the entire system.
7 Issolvi l-problemi
Qabel ma tikkuntattja lis-servizz, iċċekkja l-kwistjonijiet komuni li ġejjin:
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| L-unità ma tibda | No power; Remote control batteries low; Timer set. | Check power supply/circuit breaker; Replace batteries; Cancel timer setting. |
| Tkessiħ/tisħin insuffiċjenti | Dirty air filters; Obstruction at air inlet/outlet; Doors/windows open; Temperature setting incorrect; Refrigerant leak. | Clean air filters; Remove obstructions; Close doors/windows; Adjust temperature; Contact professional service for refrigerant issues. |
| Ħoss mhux tas-soltu | Loose parts; Fan obstruction; Unit not level. | Check for loose parts; Remove fan obstruction; Ensure unit is level. If noise persists, contact service. |
| Tnixxija ta' ilma mill-unità ta' ġewwa | Clogged drain pipe; Unit not level; Condensate pan overflow. | Clear drain pipe; Ensure unit is level; Contact professional service if issue persists. |
Jekk il-problema tippersisti wara li tipprova dawn is-soluzzjonijiet, jekk jogħġbok ikkuntattja tekniku tas-servizz kwalifikat.
8. Speċifikazzjonijiet
| Karatteristika | Dettall |
|---|---|
| Brand | CLIVET |
| Isem tal-Mudell | Kristall |
| Tip | Dual Split System |
| Kapaċità ta 'Unità ta' ġewwa | 2 x 12,000 BTU |
| Qawwa tal-Unità ta' Barra | 5.4 kW |
| Teknoloġija | Inverter |
| Klassifikazzjoni tal-Effiċjenza tal-Enerġija | A++ (as per product title) / SEER 5 (from specs) |
| Voltage | 220 Volts |
| Karatteristiċi Speċjali | Wi-Fi Connectivity, Inverter Compressor, High-Density Filter, Dust Filter |
| Recommended Room Size (per indoor unit) | 25 to 40 m² (approx. 2.7m height) |
9. Garanzija u Appoġġ
Warranty terms and conditions are typically provided with your purchase documentation. Please refer to the warranty card or contact your retailer for specific details regarding coverage period and service procedures.
For technical support, spare parts, or professional service, please contact your authorized Clivet dealer or the customer service number provided in your purchase documentation. Always provide your model number (Cristal) and serial number when seeking support.