LILYTECH ZL-7801A

ZL-7801A Multifunctional Automatic Incubator Controller User Manual

Ditta: LILYTECH | Mudell: ZL-7801A

1. Introduzzjoni u Fuqview

LILYTECH ZL-7801A Incubator Controller with attached temperature and humidity sensor

Image 1.1: The LILYTECH ZL-7801A intelligent temperature and humidity controller with its integrated sensor.

The LILYTECH ZL-7801A is an intelligent temperature and humidity controller designed for precise environmental management. Its compact design, IP65 level front panel protection, and user-friendly interface ensure convenient operation and straightforward installation. This controller is ideally suited for a variety of applications, including incubators, climate chambers, warehouses, and other environments requiring accurate temperature and humidity regulation.

This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of your ZL-7801A controller.

2. Karatteristiċi tal-prodott

Quddiem view of ZL-7801A controller with icons for temperature and humidity control ranges

Image 2.1: The ZL-7801A controller highlighting its temperature and humidity control capabilities.

  • Dual High-Capacity Outputs: Features dual 16A outputs (R2 and R3), enabling the control of larger loads such as heaters and humidifiers.
  • Timer Outputs: Includes dedicated timer outputs (R4 and R5) for specific functions like egg tray turning in incubators.
  • Disinn kompatt u Durabbli: Boasts a compact form factor with IP65 level front panel protection, ensuring durability and ease of integration.
  • Applikazzjoni versatili: Suitable for a wide range of uses, including incubators, climate chambers, and warehouse environmental control.
  • Sensor Integrat: Comes with a combined humidity and temperature sensor for accurate environmental monitoring.

3. Setup u Installazzjoni

3.1. Installazzjoni Fiżika

The ZL-7801A controller is designed for panel mounting. Ensure the installation location is dry, well-ventilated, and free from excessive vibrations or corrosive gases.

  • Daqs tat-tħaffir: A rectangular cutout of 71mm x 29mm is required for mounting the controller.
  • Livell ta' Protezzjoni: The front panel offers IP65 protection, making it resistant to dust and low-pressure water jets.

3.2. Istruzzjonijiet tal-Wiring

Proper wiring is critical for the safe and correct operation of the ZL-7801A controller. Refer to the wiring diagram below and ensure all connections are secure and comply with local electrical codes. Disconnect power before making any connections.

Detailed wiring diagram for ZL-7801A controller showing connections for power, sensor, and various outputs

Image 3.1: ZL-7801A Wiring Diagram.

Lura view of ZL-7801A controller showing terminal blocks and sensor cable

Stampa 3.2: Wara view of the ZL-7801A showing terminal connections.

Konnessjonijiet Terminali:

  • Power Supply (100-240Vac 50/60Hz): Qabbad il-wajer Live (L) mat-terminal 7 u l-wajer Newtrali (N) mat-terminal 8.
  • Sensur tat-Temperatura u l-Umdità: Connect the sensor cable to terminals 9, 10, 11, and 12 according to the color coding (Orange, Black, Red, Yellow). Ensure correct polarity.
  • Output R1 (Auxiliary Output 5A/250Vac): Connect your auxiliary device (e.g., alarm bell) to terminal 3.
  • Output R2 (Humidifier Output 16A/250Vac): Connect your humidifier to terminal 4.
  • Output R3 (Heater Output 16A/250Vac): Connect your heater to terminal 5.
  • Output R4 & R5 (Timer Outputs 3A/250Vac): Connect devices requiring timed operation, such as an egg turning motor, to terminals 1 and 2.

Caution: Incorrect wiring can damage the device or connected equipment. Always consult a qualified electrician if unsure.

4. Istruzzjonijiet Operattivi

The ZL-7801A controller features a clear digital display and intuitive buttons for easy operation. The display shows current temperature and humidity readings.

4.1. Operazzjoni Bażika

  • Power On/Off: The unit powers on automatically when connected to a suitable power source.
  • Wiri: The main display shows the current temperature and humidity measured by the sensor.
  • Buttuni: The control panel typically includes 'P' (Program/Set), 'Up Arrow', 'Down Arrow', and 'S' (Select/Confirm) buttons for navigation and parameter adjustment.

4.2. Setting Parameters (Temperature and Humidity)

To adjust the desired temperature and humidity set points, follow these general steps. Specific button sequences may vary slightly; refer to the detailed programming guide included with your product for precise instructions.

  1. Press the 'P' button to enter programming mode.
  2. Use the 'Up' or 'Down' arrow buttons to navigate through different parameters (e.g., temperature set point, humidity set point, hysteresis, calibration).
  3. Press the 'S' button to select a parameter for editing.
  4. Use the 'Up' or 'Down' arrow buttons to adjust the value.
  5. Press 'S' again to confirm the new value.
  6. Press 'P' to exit programming mode and save changes.

Setting Ranges:

  • Umdità: 5% ~ 95% RH
  • Temperatura: -20℃ ~ 60℃

5. Speċifikazzjonijiet

Detailed technical specifications for the LILYTECH ZL-7801A controller:

Karatteristika Speċifikazzjoni
Provvista tal-Enerġija 100 ~ 240Vac 50/60Hz
Sinjal ta 'Input One humidity and temperature sensor (1.5 meter wire length)
Output Load R1 (Aux) 5A/250Vac (Resistive load)
Output Load R2 & R3 (Heater/Humidifier) 16A/250Vac (Resistive load)
Output Load R4 & R5 (Timer) 3A/250Vac (Resistive load)
Firxa ta 'Setting ta' Umdità 5 ~ 95% RH
Firxa tal-issettjar tat-temperatura -20℃ ~ 60℃
Sensor Accuracy (Humidity) ±5% RH
Sensor Accuracy (Temperature) ± 1℃
Umdità tax-Xogħol 10 ~ 90% RH (without dew)
Temperatura tax-Xogħol -20 ~ 45℃
Device Size (L x W x H) 78 x 34.5 x 71 mm (3.07 x 1.36 x 2.8 pulzieri)
Drilling Size 71 x 29 mm
Materjali PC + ABS, fire proof
Livell ta' Protezzjoni IP65 (pannell ta' quddiem biss)
Piż tal-oġġett 7 uqija
Kulur Iswed

6. Manutenzjoni

Regular maintenance ensures the longevity and accurate performance of your ZL-7801A controller.

  • Tindif: Periodically wipe the front panel with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the display or casing.
  • Kura tas-Sensor: Keep the temperature and humidity sensor clean and free from dust or debris. Do not immerse the sensor in liquids. Ensure the sensor cable is not kinked or damaged.
  • Konnessjonijiet: Occasionally check all wiring connections to ensure they remain secure.
  • Ambjent: Ensure the operating environment remains within the specified working temperature and humidity ranges to prevent damage to the unit.

7 Issolvi l-problemi

This section addresses common issues you might encounter with your ZL-7801A controller. If the problem persists, contact customer support.

Problema Kawża Possibbli Soluzzjoni
Il-kontrollur ma jixgħelx. No power supply; incorrect wiring; faulty power source. Check power connections (Terminals 7 & 8). Verify power outlet is functional. Ensure correct voltage (100-240Vac).
Qari mhux korrett tat-temperatura/umdità. Sensor dirty or damaged; sensor not properly connected; sensor calibration needed. Clean the sensor. Check sensor wiring (Terminals 9-12). Refer to the detailed manual for sensor calibration procedures. Replace sensor if damaged.
Output (Heater/Humidifier) not activating. Set point not met; output wiring incorrect; faulty connected device. Verify set points and hysteresis settings. Check wiring for R2/R3 outputs. Test the connected device independently.
Timer output (R4/R5) not working. Timer settings incorrect; wiring issue; connected device fault. Review timer program settings. Check wiring for R4/R5 outputs. Ensure the connected device (e.g., egg turning motor) is functional.

8. Garanzija u Appoġġ

ZL-7801A controller in its retail box with the sensor and instruction manual

Image 8.1: The ZL-7801A controller as packaged with its accessories.

LILYTECH products are manufactured to high quality standards. For specific warranty information, please refer to the warranty card or documentation included with your product packaging. Typically, LILYTECH offers a standard manufacturer's warranty against defects in materials and workmanship.

For technical support, troubleshooting assistance beyond this manual, or warranty claims, please contact LILYTECH customer service through the contact information provided on the product packaging or the official LILYTECH website. When contacting support, please have your product model number (ZL-7801A) and purchase details ready.

Aħna impenjati li nipprovdu prodotti affidabbli u servizz tal-konsumatur eċċellenti.

Dokumenti Relatati - ZL-7801A

Preview Kontrollur tal-Umdità u t-Temperatura LILYTECH ZL-7958A għal Inkubaturi - Manwal tal-Utent
Manwal dettaljat għall-utent għall-Kontrollur tal-Umdità u t-Temperatura LILYTECH ZL-7958A, iddisinjat għal inkubaturi u kmamar tal-klima. Tgħallem dwar il-karatteristiċi, l-ispeċifikazzjonijiet, it-tħaddim u l-wajers tiegħu.
Preview Manwal tal-Kontrollur tal-Umdità u t-Temperatura LILYTECH ZL-7801D
Gwida komprensiva għall-kontrollur universali tat-temperatura u l-umdità LILYTECH ZL-7801D, li tiddeskrivi l-karatteristiċi, l-ispeċifikazzjonijiet, it-tħaddim, is-settings tal-parametri, il-loġika tal-kontroll, u l-wajers tiegħu. Adattat għal inkubaturi, kmamar tal-klima, serer, u mħażen.
Preview LILYTECH ZL-7903A Temperature and Humidity Controller - User Manual & Specifications
Comprehensive user manual and technical specifications for the LILYTECH ZL-7903A industrial intelligent temperature and humidity controller. Covers features, functions, parameters, wiring, and PID control.
Preview Kontrollur tat-Temperatura ZL-6231A: Manwal ta' Istruzzjonijiet | Lilytech
Manwal ta' struzzjonijiet komprensiv għall-Kontrollur tat-Temperatura Lilytech ZL-6231A, li jiddeskrivi l-ispeċifikazzjonijiet, it-tħaddim, is-settings tal-parametri, l-installazzjoni, u l-wajers elettriċi tiegħu għal diversi applikazzjonijiet.
Preview Manwal ta' Istruzzjoni tal-Kontrollur tat-Temperatura ZL-6231A | LILYTECH
Manwal ta' struzzjoni uffiċjali għall-Kontrollur tat-Temperatura LILYTECH ZL-6231A. Karatteristiċi, speċifikazzjonijiet, tħaddim, settings tal-parametri, installazzjoni, u dijagrammi tal-wajers.
Preview Manwal tal-Istruzzjonijiet tal-Kontrollur tal-Ħiter tal-Ilma tal-Pompa tas-Sħana ZL-R200A
Manwal ta' struzzjoni għall-Kontrollur tal-Ilma tal-Pompa tas-Sħana LILYTECH ZL-R200A, li jkopri l-funzjonijiet ewlenin, l-ispeċifikazzjonijiet tekniċi, il-kodiċijiet tal-ħsara, l-indikazzjonijiet tal-wiri, l-operazzjonijiet ewlenin, il-parametri tas-sistema, u l-funzjonijiet ta' kontroll.