Riello 71300

RIELLO Gulliver BS1 Gas Burner Instruction Manual

Ditta: Riello | Mudell: 71300

1. Introduzzjoni

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Riello Gulliver BS1 1-Stage 16-52 kW Low NOx Gas Burner. Please read this manual thoroughly before attempting any procedures with the burner.

Proper installation, commissioning, and maintenance are crucial for the safe and optimal performance of this device. Adherence to all local and national regulations is mandatory.

2. Informazzjoni dwar is-Sigurtà

TWISSIJA:

  • Installation (gas/water), initial commissioning, and maintenance of this device must only be carried out by a qualified HVAC system mechanic in accordance with valid regulations and these instructions.
  • Failure to comply with safety instructions can result in serious injury, property damage, or death.
  • Ensure the work area is well-ventilated during installation and maintenance.
  • Dejjem skonnettja l-enerġija qabel ma twettaq kwalunkwe servizz jew manutenzjoni.

Żomm dan il-manwal f'post sigur għal referenza futura.

3. Prodott Aktarview

Riello Gulliver BS1 Gas Burner

Image 1: Riello Gulliver BS1 1-Stage Gas Burner. This image shows the compact, red-cased burner unit with its metallic combustion head.

The Riello Gulliver BS1 is a single-stage monoblock gas burner designed for efficient heating applications. Key features include:

  • Single-stage monoblock design.
  • Suitable for natural gas, convertible to LPG (liquefied petroleum gas).
  • Fully automatic operation.
  • Flame tube made of stainless steel, resistant to high temperatures.
  • Mutur elettriku b'fażi waħda, 230 V, 50 Hz.

4. Speċifikazzjonijiet

Riello Gulliver BS1 Dimensions and Specifications Table

Image 2: Technical drawing with dimensions and a table of specifications for various Gulliver models, including BS1.

Riello Gulliver BS1 Technical Data
Parametru Valur
Mudell Gulliver BS 1
Tip 911 T1
Firxa tal-Qawwa 16-52 kW
Qawwa Stages 1
Dimensjonijiet (WxDxH) 234 x 276 x 295 mm
Flame Tube Length 70-116 mm
Flame Tube Diameter 89 mm
Ċertifikazzjoni CE-0085 AQ 0409
Valv tal-Gass MBDLE 055
Konnessjoni R 1/2 Inch Max.
Pressjoni tad-Dħul 65 mbar
Multibloc Gas Valve Features Integrated components: Filter, Pressure Regulator, Gas Pressure Monitor (shuts off if minimum gas pressure is not met), Safety Valve, Single-stage Operating Valve with Ignition Gas Flow Control (fast opening) and slow opening of main gas volume.
Wiring Ready for plug-in connection.
Flanġ Pre-assembled connection flange to the burner.
Approvazzjonijiet Joint approval for burner and gas valve.

5. Setup u Installazzjoni

The Riello Gulliver BS1 burner comes with a Multibloc Gas Valve and assembly and operating instructions. It is crucial that installation is performed by a qualified professional.

5.1 Kontrolli ta' qabel l-installazzjoni

  • Verify that the burner model matches the requirements of the heating appliance.
  • Ensure all components listed in the delivery scope are present.
  • Check for any visible damage to the burner or its components.

5.2 Immuntar tal-Burner

Mount the burner securely to the boiler or heating appliance using the pre-assembled connection flange. Ensure a gas-tight seal according to relevant standards.

5.3 Konnessjonijiet tal-Gass u tal-Elettriku

  • Connect the gas supply to the Multibloc Gas Valve (R 1/2 Inch Max. inlet pressure: 65 mbar).
  • Perform a gas leak test after connection.
  • Connect the burner to a 230 V, 50 Hz single-phase electrical supply. The burner is supplied ready for plug-in connection.
  • Żgura ertjar xieraq.

5.4 Kummissjonar Inizjali

Initial commissioning must be performed by a qualified technician. This involves:

  • Adjusting the burner for optimal combustion based on the heating appliance's requirements.
  • Checking all safety devices and controls.
  • Verifying proper flame detection and ignition sequence.

6. Istruzzjonijiet Operattivi

The Riello Gulliver BS1 burner operates automatically once properly installed and commissioned. Users should be aware of the following:

6.1 Starting the Burner

  1. Ensure the heating system is filled and vented.
  2. Turn on the main power supply to the burner.
  3. Set the thermostat or control system to demand heat. The burner will initiate its automatic start-up sequence.

6.2 Shutting Down the Burner

  • To temporarily stop operation, lower the thermostat setting or turn off the heating demand.
  • For extended shutdown or maintenance, turn off the main power supply to the burner at the dedicated switch.
  • For complete system shutdown, close the main gas supply valve.

6.3 Indikazzjoni ta' Żball

The burner is equipped with a control box that indicates operational status and potential faults. Refer to the detailed operating instructions provided with the burner for specific error codes and their meanings.

7. Manutenzjoni

Regular maintenance is essential for the safe, efficient, and long-lasting operation of your Riello Gulliver BS1 burner. Maintenance must be performed by a qualified HVAC system mechanic.

7.1 Manutenzjoni Annwali

  • Combustion Analysis: Check and adjust combustion parameters (CO2, O2, CO, flue gas temperature) to ensure optimal efficiency and low emissions.
  • Burner Head and Flame Tube Cleaning: Inspect and clean the burner head, flame tube, and ignition electrodes to remove any soot or deposits.
  • Fan and Air Inlet Cleaning: Clean the fan impeller and air inlet grilles to ensure proper airflow.
  • Gas Valve Inspection: Check the gas valve and associated components for proper operation and leaks.
  • Konnessjonijiet elettriċi: Spezzjona l-konnessjonijiet elettriċi kollha għal issikkar u sinjali ta' xedd.
  • Apparat tas-Sigurtà: Test all safety devices, including the gas pressure monitor and flame sensor.

7.2 User Checks (Daily/Weekly)

  • Observe the burner's operation for any unusual noises or smells.
  • Check the pressure gauge on the heating system.
  • Ensure the area around the burner is clear of obstructions and flammable materials.

8 Issolvi l-problemi

If the burner malfunctions, consult the detailed troubleshooting guide in the original operating instructions. Below are some common issues and general advice:

Xenarji Komuni ta' Soluzzjoni ta' Problemi
Problema Kawża Possibbli Azzjoni
Il-berner ma jibdax No power supply, thermostat not calling for heat, safety lockout, gas supply off. Check power, thermostat setting, gas valve. Reset burner if in lockout (refer to manual). If problem persists, contact a qualified technician.
Burner starts but locks out quickly No flame detected, insufficient air/gas mixture, faulty ignition. Do NOT attempt to fix yourself. This requires a qualified technician to inspect and adjust the burner.
Ħoss jew riħa mhux tas-soltu Combustion issues, mechanical fault, gas leak. Immediately shut off gas supply and power. Ventilate the area. Do NOT attempt to restart. Contact emergency services and a qualified technician.

For any issues beyond simple checks, always contact a qualified and certified HVAC technician. Do not attempt repairs yourself.

9. Garanzija u Appoġġ

For warranty information, please refer to the documentation provided at the time of purchase or contact your seller. Riello products are known for their quality and reliability.

For technical support, spare parts, or service, please contact your authorized Riello dealer or a qualified HVAC system mechanic. Ensure to provide the model number (71300) and serial number of your burner when seeking support.

You can find more information and contact details on the official Riello websit: www.riello.com

Dokumenti Relatati - 71300

Preview Priročnik za namestitev, uporabo in vzdrževanje gorilnika RIELLO Gulliver RG1NR na plinsko olje
Ta dokument vsebuje podrobna navodila za namestitev, uporabo, vzdrževanje in odpravljanje napak enostopenjskega gorilnika RIELLO Gulliver RG1NR na plinsko olje, vključno s tehničnimi podatki, varnostnimi predpisi ožprav postol predpisje ožavv.
Preview Lista u Dijagramma tal-Partijiet tal-Burner taż-Żejt Riello Gulliver RG2F
Lista dettaljata tal-ispare parts u dijagramma tal-komponenti għall-burner taż-żejt ħafif Riello Gulliver RG2F (Mudell 377T1, Kodiċi 3737770), inklużi n-numri tal-partijiet u d-deskrizzjonijiet bl-Ingliż.
Preview Manuale di Installazione e Manutenzione Bruciatore Gas ad Aria Soffiata RIELLO RS 160/M BLU
Questo documento jipprovdi istruzioni per l'installazione, l'uso e la manutenzione del bruciatore gas ad aria soffiata RIELLO RS 160/M BLU. Inkludi dati tecnici, specifiche elettriche e guide alla riżoluzzjoni dei problemi.
Preview Manwal tal-Installazzjoni tal-Burners taż-Żejt Residenzjali Riello Serje 40 F3 & F5
Dan il-manwal jipprovdi struzzjonijiet dettaljati għall-installazzjoni għar-Riello 40 Series Residential Oil Burners, mudelli F3 u F5. Ikopri l-identifikazzjoni tal-komponenti, is-setup, l-immuntar, il-konnessjonijiet elettriċi, it-tqegħid taż-żennuni, u l-proċeduri ta' aġġustament. Il-manwal huwa maħsub għal applikazzjonijiet ta' retrofit u jinkludi dejta teknika, speċifikazzjonijiet, u listi ta' spare parts.
Preview Riello 40 BF Single StagManwal ta' Installazzjoni u Tħaddim tal-Burner taż-Żejt
Manwal komprensiv għall-installazzjoni u t-tħaddim tar-Riello 40 BF single-stagBurner taż-żejt elettroniku, li jkopri speċifikazzjonijiet tekniċi, proċeduri ta' installazzjoni, dijagrammi tal-wajers, issolvi l-problemi, u spare parts.
Preview Riello P 140 P/N 471 M1 Heavy Oil Burner Installation and Maintenance Instructions
Comprehensive installation, use, and maintenance instructions for the Riello P 140 P/N 471 M1 heavy oil burner. Covers technical specifications, electrical diagrams, fuel supply systems, and adjustment procedures.