Introduzzjoni
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Ferroli DIVATECH D LN C 24 Open Chamber Boiler. Please read this manual thoroughly before attempting any installation or operation. Keep this manual for future reference.
Informazzjoni dwar is-Sigurtà
Always adhere to local regulations and safety standards during installation and operation. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Consult a qualified installer, service agency, or the gas supplier for information or assistance.
- Persunal kwalifikat: L-installazzjoni u l-manutenzjoni għandhom jitwettqu biss minn persunal kwalifikat u awtorizzat.
- Provvista tal-Gass: Ensure the gas supply is turned off before any service or maintenance.
- Ventilazzjoni: This is an open chamber boiler; ensure adequate ventilation as per local codes to prevent carbon monoxide buildup.
- Pressjoni tal-Ilma: Do not operate the boiler if the water pressure is outside the recommended range.
- Tfal: Keep children away from the boiler and its controls.
Setup u Installazzjoni
Installation of the Ferroli DIVATECH D LN C 24 boiler requires professional expertise. Refer to the detailed installation guide provided separately with the product for specific instructions regarding plumbing, gas connection, electrical wiring, and flue system setup.
Kontrolli ta' qabel l-installazzjoni:
- Verify that the boiler model matches the gas type available (methane).
- Ensure the installation site meets all ventilation and space requirements.
- Check the integrity of the packaging and the boiler for any transport damage.
Mounting the Boiler:
The boiler should be securely mounted on a solid wall capable of supporting its weight (27 kg). Use appropriate wall fixings. Ensure the boiler is level to guarantee proper operation and drainage.

Figura 1: Quddiem view of the Ferroli DIVATECH D LN C 24 Open Chamber Boiler. The boiler is white with a grey control panel located at the bottom right, featuring a digital display and pressure gauge. The Ferroli logo is visible above the control panel.
Istruzzjonijiet Operattivi
Start-up Inizjali:
- Kun żgur li l-konnessjonijiet kollha tal-gass, tal-ilma u tal-elettriku huma sikuri u mingħajr tnixxija.
- Iftaħ il-valv prinċipali tal-gass.
- Fill the heating system with water until the pressure gauge reads between 1 and 1.5 bar. Bleed air from the system.
- Turn on the electrical supply to the boiler.
- Set the boiler to heating mode using the control panel.
Operazzjoni ta' Kuljum:
- Aġġustament tat-temperatura: Use the temperature control knobs on the front panel to set the desired heating and domestic hot water temperatures.
- Monitoraġġ tal-Pressjoni: Regularly check the system pressure on the gauge. If it drops below 1 bar, repressurize the system.
- Kodiċi ta' Żball: The digital display will show error codes if a fault occurs. Refer to the troubleshooting section for common codes.
Manutenzjoni
Regular maintenance is crucial for the longevity and efficient operation of your boiler. It is recommended to have the boiler serviced annually by a qualified technician.
Manutenzjoni tal-Utent:
- Tindif: Wipe the exterior of the boiler with a soft, damp drapp. Tużax tindif li joborxu.
- Kontroll tal-Pressjoni: Monitor system pressure weekly.
- Ventilazzjoni: Kun żgur li ż-żona madwar il-bojler tkun vojta u li l-fetħiet tal-ventilazzjoni ma jkunux ostakolati.
Manutenzjoni Professjonali:
- Annual inspection and cleaning of the heat exchanger and burner.
- Iċċekkjar u aġġustament tal-pressjoni tal-gass.
- Verification of safety devices and controls.
- Analiżi tal-gass taċ-ċumnija.
Issolvi l-problemi
Before calling for service, consult the following table for common issues and their solutions. For persistent problems or issues not listed, contact a qualified technician.
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| L-ebda tisħin/ilma sħun | Pressjoni baxxa tas-sistema | Repressurize the system to 1-1.5 bar. |
| L-ebda tisħin/ilma sħun | Provvista tal-gass mitfija | Check if the main gas valve is open. |
| Boiler lockout/Error code | Nuqqas ta 'tqabbid | Reset the boiler. If it persists, call a technician. |
| Il-bojler jagħmel ħsejjes mhux tas-soltu | Air in the system / Limescale buildup | Bleed radiators. For limescale, professional descaling is required. |
Speċifikazzjonijiet
- Ditta: Ferroli
- Numru tal-Mudell: 500001
- Dimensjonijiet tal-Prodott (L x W x H): 5.99 x 13.51 x 5.99 ċm (madwar 2.36 x 5.32 x 2.36 pulzieri)
- Piż: 27 Kilogrammi (madwar 59.5 lbs)
- Materjal: 18/8 stainless steel (internal components, where applicable)
- Tip: Bojler tal-Kamra Miftuħa
- Tip ta' Fjuwil: Metanu (Gass Naturali)
- ASIN: B07PX285Y8
- L-Ewwel Data Disponibbli: 30 ta’ Marzu, 2019
Garanzija u Appoġġ
For warranty information, please refer to the warranty card included with your product or contact Ferroli customer service. Keep your proof of purchase for warranty claims.
For technical support, spare parts, or to schedule professional service, please contact your authorized Ferroli dealer or visit the official Ferroli website. Always provide your model number (500001) and serial number when seeking support.
Vidjows tal-Prodott
Ma nstab l-ebda vidjow uffiċjali tal-prodott mill-bejjiegħ li huwa rilevanti għall-inklużjoni f'dan il-manwal.