1. Prodott Aktarview
The EPEVER TRIRON 4210N is a 40A Maximum Power Point Tracking (MPPT) solar charge controller designed for 12V/24V DC systems. It efficiently manages power from solar panels to charge various battery types, including lead-acid (Sealed, Gel, Flooded, User) and lithium (LiFePO4, Li-NiCoMn, Lithium User). This set includes the TRIRON 4210N controller and the MT50 Remote Meter for enhanced monitoring and control.
Karatteristiċi ewlenin:
- Advanced MPPT technology for high tracking efficiency.
- Modular design for flexible configuration with different display and interface modules.
- Supports multiple battery types: Sealed (AGM), Gel, Flooded, Lead-acid User, LiFePO4 Lithium, Li(NiCoMn)O2 Lithium, Lithium User (9~34V).
- Negative ground design for broad application compatibility.
- Dual 5V DC USB output interface (Max 2.2A) for charging electronic devices.
- Erba'-stage charging (bulk, absorption, float, equalization) to prolong battery life.
- Comprehensive electronic protection features.
- Funzjoni tal-istatistika tal-enerġija f'ħin reali.
Kontenut tal-Pakkett:
Il-pakkett tipikament jinkludi:
- EPEVER TRIRON 4210N MPPT Solar Charge Controller
- Miter mill-bogħod EPEVER MT50
- Remote Temperature Sensor (RT-S)
- USB to RS485 Communication Cable
- Manwal għall-Utent

Image: Contents of the EPEVER TRIRON 4210N and MT50 Remote Meter package, including the controller, remote meter, temperature sensor, and cables.
2. Informazzjoni dwar is-Sigurtà
Jekk jogħġbok aqra l-istruzzjonijiet u t-twissijiet kollha bir-reqqa qabel l-installazzjoni u t-tħaddim. Jekk ma ssegwix dawn l-istruzzjonijiet, dan jista' jirriżulta f'xokk elettriku, nar, jew korriment serju.
- Ensure all wiring is correctly polarized and securely connected. Loose connections can cause overheating and fire.
- Always connect the battery to the charge controller first, then the solar panel, and finally the load. Disconnect in the reverse order.
- Do not attempt to repair or modify the controller. Refer servicing to qualified personnel.
- Install the controller in a well-ventilated area, away from flammable materials and corrosive gases.
- Wear appropriate personal protective equipment (PPE), including eye protection and insulated gloves, when working with batteries and solar panels.
- Tiżgura s-sistema voltage is compatible with the controller's specifications (12V/24V auto work).
- Use appropriate circuit breakers or fuses for all connections to prevent overcurrent.
3. Installazzjoni
3.1 Immuntar tal-Kontrollur
Mount the controller vertically on a flat, non-flammable surface in a dry, well-ventilated indoor area. Ensure there is sufficient clearance around the controller for heat dissipation. The recommended clearances are 150mm (5.9 inches) above and below the unit.

Image: Controller dimensions and recommended mounting clearances for proper ventilation.
3.2 Konnessjonijiet tal-Wiring
Follow the wiring sequence carefully to prevent damage to the controller or other components. Always ensure all power sources are disconnected before making or breaking connections.
- Qabbad il-batterija: Connect the battery cables to the controller's battery terminals (marked with '+' and '-'). Ensure correct polarity. Always connect the battery first.
- Qabbad il-Panel Solari: Connect the solar panel cables to the controller's PV terminals (marked with solar panel icon and '+' and '-'). Ensure correct polarity.
- Qabbad it-Tagħbija DC: Connect the DC load cables to the controller's load terminals (marked with light bulb icon and '+' and '-'). Ensure correct polarity.
- Connect Remote Temperature Sensor: Plug the remote temperature sensor into the designated port on the controller. Secure the sensor to the battery case for accurate temperature compensation.

Image: Detailed wiring diagram showing connections for solar panels, battery, and DC load to the TRIRON 4210N controller.
Video: This video demonstrates the unboxing, component identification, and step-by-step installation process for the EPEVER TRIRON 4210N solar charge controller, including wiring the battery, solar panel, and remote temperature sensor.
3.3 Connecting the MT50 Remote Meter
The MT50 Remote Meter connects to the controller via an RJ45 communication cable. This allows for remote monitoring of system status and parameter settings.
- Connect one end of the RJ45 cable to the RS485 port on the TRIRON 4210N controller.
- Connect the other end of the RJ45 cable to the corresponding port on the MT50 Remote Meter.
3.4 Interfaces tal-Komunikazzjoni
The TRIRON 4210N features an RS485 communication port, allowing connection to various accessories for extended functionality:
- Softwer tal-PC: Connect via an RS485 to USB adapter cable for monitoring and parameter configuration using PC software.
- App mobbli: Connect via an eBox-WIFI-01 or eBox-BLE-01 module for wireless monitoring and control through a mobile application.
4. Operazzjoni
4.1 Wiri u Buttuni LCD
The controller features an LCD display and five buttons for viewing system parameters and making adjustments.

Image: Various screens displayed on the TRIRON 4210N LCD, showing PV voltage, current, battery status, and load information.
- PV/+ Button: Used to navigate forward through display screens or increase parameter values.
- BATT/→ Button: Used to navigate right through display screens or move cursor during parameter setting.
- LOAD/- Button: Used to navigate backward through display screens or decrease parameter values.
- Buttuna SET: Użat biex tidħol fil-modalità tal-issettjar tal-parametri jew tikkonferma setting.
- Buttuna ESC: Used to exit parameter setting mode or return to the previous screen.
4.2 Settings tal-Parametru
To adjust parameters such as battery type, capacity, and temperature unit, use the navigation buttons to access the setting menus. Press the SET button to enter edit mode, use PV/+ and LOAD/- to change values, and SET again to confirm. Refer to the detailed instructions in the included user manual for specific parameter adjustments.
4.3 Output USB
The controller is equipped with dual 5V DC USB ports (Max 2.2A) for charging compatible electronic devices. These ports are active when the controller is powered by the battery.
5. Manutenzjoni
Manutenzjoni regolari tiżgura prestazzjoni ottimali u lonġevità tal-kontrollur tal-iċċarġjar solari tiegħek.
- Iċċekkja l-Konnessjonijiet: Spezzjona perjodikament il-konnessjonijiet tal-wajers kollha għal issikkar u korrużjoni. Issikka kwalunkwe konnessjoni maħlula.
- Naddaf il-Kontrollur: Keep the controller clean and free from dust and debris. Ensure the heat sink fins are not obstructed to allow for proper cooling.
- Spezzjona Kejbils: Check all cables for signs of wear, damage, or insulation degradation. Replace damaged cables immediately.
- Spezzjoni tal-batterija: For lead-acid batteries, check electrolyte levels and terminal condition as per battery manufacturer guidelines.
- Aġġornamenti tas-Software: Iċċekkja l-manifattur website for any available firmware updates for your controller.
6 Issolvi l-problemi
This section provides basic troubleshooting steps for common issues. For more complex problems, consult the full user manual or contact EPEVER technical support.
Kwistjonijiet Komuni u Soluzzjonijiet:
- Ebda Wiri/Ebda Qawwa:
- Iċċekkja l-konnessjonijiet tal-batterija u kun żgur li huma sikuri u polarizzati b'mod korrett.
- Ivverifika l-volum tal-batterijatage jinsab fil-medda operattiva tal-kontrollur.
- No Charging from Solar Panel:
- Iċċekkja l-konnessjonijiet u l-polarità tal-pannelli solari.
- Kun żgur li biżżejjed dawl tax-xemx qed jilħaq il-pannelli solari.
- Verify solar panel open circuit voltage (Voc) is within the controller's input range.
- It-Tagħbija Mhux Taħdem:
- Check load connections and polarity.
- Ensure the load is not exceeding the controller's rated load current.
- Iċċekkja l-volum tal-batterijatage; the load may be disconnected if the battery voltage huwa baxx wisq.
- Incorrect Battery Readings:
- Verify the remote temperature sensor is correctly connected and placed near the battery.
- Ensure the correct battery type and capacity are set in the controller's parameters.
7. Speċifikazzjonijiet
| Parametru | Valur |
|---|---|
| Mudell | TRIRON4210N-mppt |
| Sistema Voltage | 12/24VDC Auto Work |
| Kurrent ta' Ċarġ Rated | 40A |
| Input tal-batterija Voltage Firxa | 8-32V |
| Max. PV Ċirkwit Miftuħ Voltage | 100V (Min operating environment temp); 92V (25℃ environment temp) |
| MPP Voltage Firxa | (Vbat+2V) ~ 72V |
| Max. PV Array Power Support | 520W (12V battery); 1040W (24V battery) |
| Temperatura tal-Ambjent tax-Xogħol | -25℃ ~ +55℃ (with LCD) / -30℃ ~ +55℃ (without LCD) |
| Lithium Battery Types Supported | LiFePO4 (4 series; 8 series) / Li-NiCoMn (3 series; 6 series) / User (Lithium battery setting requires RS485 or WIFI BOX) |
| Lead-acid Battery Types Supported | Sealed (AGM), Gel, Flooded, Lead-acid User |
| Awto-konsum | ≤14mA (12V); ≤15mA (24V) |
| Kumpens tat-Temperatura | -3mV / ℃ / 2V |
| L-ert | Negattiv Komuni |
| Terminals/Wire Size | 6AWG (16mm²) |
| Output USB | Dual 5V DC, Max 2.2A |
| Piż tal-oġġett | 6.69 liri |
| Dimensjonijiet tal-Pakkett | 17.56 x 8.43 x 4.88 pulzieri |
| UPC | 655160074776 |
8. Garanzija u Appoġġ
For warranty information and technical support, please refer to the documentation included with your product or visit the official EPEVER websit. Żomm l-irċevuta tax-xiri tiegħek bħala prova tax-xiri għal talbiet ta' garanzija.