Introduzzjoni
This manual provides comprehensive instructions for the setup, operation, maintenance, and troubleshooting of your Datalogic Gryphon GM4500 Wireless Barcode Scanner Kit. Please read this manual thoroughly before using the device to ensure proper functionality and to prevent damage.
Kontenut tal-Pakkett
Ivverifika li l-oġġetti kollha huma preżenti fil-pakkett tiegħek:
- Datalogic Gryphon GM4500 Wireless Barcode Scanner (GM4500-BK-433K1)
- Wireless Charging Base (WLC4090-BK-433)
- USB Cable (90A052258)
- Batterija tal-jone tal-litju (installata minn qabel jew separata)
Prodott Overview
The Datalogic Gryphon GM4500 is a high-performance wireless barcode scanner designed for various applications. Below is an illustration of the scanner's main components.

Image: Datalogic Gryphon GM4500 Wireless Barcode Scanner. This image shows the black handheld scanner with its scan window emitting light, and a blue trigger button on the handle. The base of the handle features a wireless charging indicator.
Komponenti Ewlenin:
- Tieqa tal-Iskanjar: Area where barcodes are read.
- Buttuna Trigger: Activates the scanning beam.
- Dwal indikaturi: Provide feedback on status (e.g., battery, scan success).
- Wireless Charging Contacts: Located at the base of the scanner for charging with the WLC4090-BK-433 base.
- Bażi tal-Iċċarġjar bla fili: Connects to the host system via USB and charges the scanner.
Setup
- Iċċarġja l-Iskaner:
- Connect the USB cable to the Wireless Charging Base (WLC4090-BK-433) and then to a powered USB port on your computer or a USB power adapter.
- Place the Gryphon GM4500 scanner onto the charging base. Ensure the charging contacts align.
- The scanner's indicator light will show charging status. Allow sufficient time for a full charge before first use.
- Connect the Base to Host System:
The charging base also acts as the communication interface. Once connected via USB, your operating system should automatically detect and install the necessary drivers. If not, refer to Datalogic's official websit għat-tniżżil tas-sewwieqa.
- Pairing the Scanner with the Base:
The scanner and base are typically pre-paired. If pairing is lost or you are setting up a new scanner/base combination:
- Ensure the base is powered and connected to the host system.
- Refer to the Datalogic Gryphon GM4500 Quick Reference Guide (usually included or available online) for specific pairing barcode sequences. Scan the designated pairing barcode with the scanner.
- A successful pairing will be indicated by an audible beep and/or a specific LED pattern on both the scanner and the base.
Istruzzjonijiet Operattivi
- Skennjar ta' Barcode:
- Point the scan window of the Gryphon GM4500 at the barcode you wish to read.
- Press and hold the trigger button. A red aiming beam or illumination pattern will appear.
- Position the scanner so the aiming beam covers the entire barcode.
- Once the barcode is successfully read, the scanner will emit a short beep and/or an indicator light will flash green. The data will be transmitted to your host system.
- Reading Difficult Barcodes:
For poorly printed, damaged, or reflective barcodes, try adjusting the distance and angle of the scanner. Sometimes, scanning from a slight angle can improve readability.
- Indikazzjoni tal-Livell tal-Batterija:
The scanner typically has an LED indicator that changes color or flashes to indicate the battery charge level. Refer to the full product manual for specific LED patterns and their meanings.
Manutenzjoni
- Tindif tal-Iskaner:
Regularly clean the scan window and the exterior of the scanner. Use a soft, lint-free cloth lightly dampened with water or a mild, non-abrasive cleaning solution. Do not use harsh chemicals or abrasive materials, as these can damage the device.
- Kura tal-batterija:
To prolong battery life, avoid exposing the scanner to extreme temperatures. Charge the battery regularly and avoid completely draining it whenever possible. If the scanner will be stored for an extended period, ensure it has a partial charge (around 50%) and store it in a cool, dry place.
- Ħażna:
When not in use, store the scanner on its charging base or in a safe location to prevent accidental drops or damage.
Issolvi l-problemi
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Scanner does not turn on or respond. | Batterija baxxa jew eżawrita. | Place the scanner on the charging base and allow it to charge for at least 30 minutes. |
| L-iskaner ma jaqrax il-barcodes. |
|
|
| Data is not transmitted to the host system. |
|
|
Speċifikazzjonijiet
| Karatteristika | Dettall |
|---|---|
| Numru tal-Mudell | GM4500-BK-433K1 |
| Teknoloġija tal-Konnettività | Wireless (433 MHz), USB Cable (for base) |
| Sors tal-Enerġija | Li jaħdem bil-batterija (batterija tal-jone tal-litju inkluża) |
| Piż tal-oġġett | 8.6 uqija |
| Dimensjonijiet tal-Prodott | 5.12 x 5.12 x 7.87 pulzieri |
| Manifattur | Datalogic |
| L-Ewwel Data Disponibbli | 5 ta’ Frar, 2019 |
Garanzija u Appoġġ
For detailed warranty information, please refer to the warranty card included with your product or visit the official Datalogic website. For technical support, driver downloads, or further assistance, please contact Datalogic customer service directly.
Manifattur: Datalogic
Websit: www.datalogic.com