Istruzzjonijiet Importanti dwar is-Sigurtà
Aqra l-istruzzjonijiet kollha qabel ma tinstalla jew tuża dan il-ħiter. Jekk ma ssegwix dawn l-istruzzjonijiet, dan jista' jirriżulta f'nar, xokk elettriku, korriment serju, jew mewt.
- Konnessjoni Elettrika: This heater operates on 240 Volts. All wiring must be performed by a qualified electrician and comply with national and local electrical codes.
- L-ertjar: Dan il-heater għandu jkun ertjat.
- Post: Do not install the heater near flammable materials, in areas where gasoline, paint, or other flammable liquids are stored, or where explosive dust is present. Maintain minimum clearances from walls and other objects as specified in the installation section.
- Superviżjoni: Close supervision is necessary when any heater is used by or near children or invalids, and whenever the heater is left operating and unattended.
- Is-sħana żejda: To avoid overheating, do not cover the heater. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire, or damage the heater.
- Manutenzjoni: Disconnect power at the main service panel before performing any maintenance or cleaning.
- Termostat: A separate thermostat is required for operation and is sold separately. Ensure the thermostat is compatible with a fan-forced heater.
Prodott Overview
The Stelpro pulsair RWF0502W is a 240V wall-mounted fan heater designed for supplemental heating in various rooms such as bedrooms, home offices, and living rooms. It utilizes both convection and forced air heating methods to efficiently distribute warmth.

Quddiem view of the Stelpro pulsair RWF0502W wall fan heater, showing the fan grille and lower air outlet.

Diagram showing the dimensions of the Stelpro pulsair RWF0502W wall fan heater: 17 1/8 inches (435 mm) height, 8 11/16 inches (220 mm) width, and 3 3/16 inches (80 mm) depth.
Installazzjoni
Lista ta' Kontroll ta' Qabel l-Installazzjoni:
- Kun żgur li l-enerġija hija skonnettjata mis-circuit breaker prinċipali.
- Ivverifika li l-provvista voltage matches the heater's rating (240V).
- Confirm you have a compatible wall thermostat (sold separately).
- Gather necessary tools: screwdriver, wire strippers, drill, level, measuring tape.
Għażliet ta 'Immuntar:
The RWF0502W heater can be either surface-mounted directly to the wall or recessed into the wall for a flush finish. Ensure adequate clearance from floors, ceilings, and adjacent walls as per local codes and manufacturer recommendations.

The Stelpro pulsair RWF0502W wall fan heater installed in a modern entryway, positioned below a plant and mirror.

The Stelpro pulsair RWF0502W wall fan heater installed on a blue wall in an entryway, with coats and shoes nearby.
Konnessjoni Elettrika:
This heater requires a 240V hardwired connection. Follow the wiring diagram provided and ensure all connections are secure and properly insulated. Connect the heater to a dedicated circuit protected by the appropriate circuit breaker.

Diagram illustrating the 240V hardwired connection for the Stelpro pulsair RWF0502W wall fan heater, showing wires connecting within a junction box.
- Turn off power at the main electrical panel.
- Remove the front grille of the heater to access the wiring compartment.
- Connect the supply wires to the heater's terminals according to the wiring diagram. Ensure proper grounding.
- Secure all connections with wire nuts and ensure no bare wires are exposed.
- Reattach the front grille.
- Install the external wall thermostat according to its manufacturer's instructions.
Operazzjoni
The Stelpro pulsair RWF0502W heater is controlled by an external wall thermostat (not included). Once installed and wired correctly, follow these steps:
- Qawwa Mixgħul: Restore power to the heater circuit at the main electrical panel.
- Issettjar tat-termostat: Adjust the external thermostat to your desired temperature. The heater will activate when the room temperature falls below the set point.
- Operazzjoni Inizjali: During the first few minutes of operation, the heater may emit a slight odor due to the burning off of manufacturing residues. This is normal and will dissipate quickly.
- Firxa tat-Temperatura: The heater is designed to operate within a temperature range of 5°C (41°F) to 30°C (86°F).
For optimal performance, avoid placing furniture or other obstructions directly in front of the heater's air outlets.
Manutenzjoni
Regular maintenance ensures efficient and safe operation of your Stelpro pulsair heater. Always disconnect power at the main circuit breaker before performing any maintenance.
- Tindif:
- Imsaħ il-barra tal-ħiter b'ċarruta ratba u damp drapp. Tużax tindif jew solventi li joborxu.
- Periodically vacuum the air intake and outlet grilles to remove dust and lint buildup.
- Spezzjoni: Annually inspect the heater for any signs of damage, loose connections, or unusual wear. If any issues are found, contact a qualified electrician for repair.
- No Lubrication: Il-mutur huwa llubrikat b'mod permanenti u ma jeħtieġ l-ebda żejt addizzjonali.
Issolvi l-problemi
If your Stelpro pulsair heater is not operating correctly, consult the following table before contacting customer support.
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Il-heater ma jixgħelx. | Ebda enerġija għall-unità. Termostat issettjat baxx wisq. Circuit breaker waqaf. | Check main electrical panel. Żid is-setting tat-termostat. Reset circuit breaker. |
| Il-ħiter ma jipproduċix biżżejjed sħana. | Daqs tal-kamra kbir wisq għall-ħiter. Airflow obstructed. Thermostat calibration issue. | Ensure heater is appropriately sized for the room. Clear obstructions from grilles. Consult thermostat manual or a qualified electrician. |
| Storbju mhux tas-soltu waqt it-tħaddim. | Komponenti sfużi. Debris fil-fann. | Disconnect power and inspect for loose parts. Disconnect power and carefully remove any debris. If noise persists, contact support. |
| Heater cycles on and off too frequently. | Thermostat location or setting. Il-protezzjoni kontra s-sħana żejda hija attivata. | Relocate thermostat away from drafts or direct heat sources. Adjust thermostat differential. Ensure grilles are clear and heater is not covered. Allow unit to cool. |
Speċifikazzjonijiet
| Karatteristika | Dettall |
|---|---|
| Brand | Stelpro |
| Numru tal-Mudell | RWF0502W |
| Tip ta 'Immuntar | Wall Mount (Surface or Recessed) |
| Tip ta' Kamra | Kamra tas-sodda, Uffiċċju tad-Dar, Kamra tal-Ħajja |
| Voltage | 240 Volts |
| Ampetà | 2.08 Amps |
| Metodu tat-Tisħin | Convection, Forced Air |
| Issettjar tat-Temperatura Min | 5 Gradi Celsius (41°F) |
| Issettjar tat-Temperatura Max | 30 Gradi Celsius (86°F) |
| Piż tal-oġġett | 7 liri |
| Dimensjonijiet tal-Pakkett | 17.72 x 9.13 x 3.58 pulzieri |
| UPC | 626296002285 |
Garanzija
Stelpro products are manufactured to high standards and are covered by a limited warranty. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Stelpro websit. Żomm il-prova tax-xiri tiegħek għal talbiet ta' garanzija.
Appoġġ għall-Klijent
For technical assistance, replacement parts, or further inquiries, please contact Stelpro customer service. Contact information can typically be found on the product packaging, the official Stelpro website, or by referring to the documentation included with your purchase.