Elitech ILD-100H

Manwal tal-Utent tad-Ditekter tat-Tnixxijiet tar-Refriġerant Elitech ILD-100H HVAC

Model: ILD-100H | Brand: Elitech

1. Introduzzjoni u Fuqview

The Elitech ILD-100H is an advanced HVAC refrigerant leak detector designed for precise and efficient detection of various halogenated refrigerants. Utilizing a heated diode sensor, it offers enhanced accuracy and reliability compared to traditional sensors. This manual provides detailed instructions for the proper setup, operation, maintenance, and troubleshooting of your ILD-100H detector, ensuring optimal performance and longevity.

This device is suitable for detecting a wide range of refrigerants, including CFCs, HFCs, HCFCs, HCs, HFOs, and mixed refrigerants such as R11, R22, R404a, R410a, R600a, R1234yf, and various blends like AZ-50, HP62, and MP39. It boasts an immediate response time, making leak detection quick and effective.

2. Karatteristiċi ewlenin

  • Heated Diode Sensor: Provides superior accuracy for all halogenated refrigerants, ensuring reliable detection results.
  • Skrin TFT: The innovative TFT screen offers clear and easy-to-read information, including sensitivity levels, leakage alerts, and battery status, enhancing operational clarity.
  • Sensittività Għolja: Features adjustable sensitivity with High, Medium, and Low levels. The maximum sensitivity reaches up to 0.1 oz/yr, allowing for the detection of even minute leaks.
  • Operazzjoni ta 'malajr: Equipped with two intuitive buttons on the front panel for rapid adjustment of sensitivity and direct muting of the buzzer, simplifying user interaction.
  • Broad Refrigerant Compatibility: Capable of detecting all types of halogenated refrigerants, including HFCs (R134a, R410A, R407C, R417A, R404A, R507, R23, R508A, R508B, R152A, R32), HCFCs (R22, R123, R124, R141b, R142b, R402A, R402B, R408A, R409A), CFCs (R11, R12, R13, R502, R503), PFCs (PFC-14, PFC-116, PFC-218), and HFOs (R-1234yf), as well as HCs (R50, R170, R290, R600, R600A, R1150, R1270).
Elitech ILD-100H Halogen Leak Detector highlighting adjustable sensitivity, audible & light alarm, immediate response, and two different modes.

Figura 2.1: Aktarview of Elitech ILD-100H key features.

3. Komponenti u Dimensjonijiet tal-Prodott

Elitech ILD-100H with labeled components including flexible probe, UV LED, filter components, display screen, buttons, and buzzer.

Figure 3.1: Labeled components of the Elitech ILD-100H.

Elitech ILD-100H dimensions showing 7.9 inches height, 3.3 inches width, 1.5 inches depth, and a 14-inch probe length. Also lists max sensitivity, response time, battery, and compliance standards.

Figure 3.2: Physical dimensions and key performance specifications.

4. Setup

  1. Spakkjar: Carefully remove the Elitech ILD-100H and all accessories from the packaging. Inspect for any signs of damage.
  2. Iċċarġjar tal-batterija: The device includes a Lithium Metal battery. Before first use, ensure the battery is fully charged. Connect the appropriate charging cable (not specified in data, assume standard USB-C based on reviews) to the device and a power source. The TFT screen will indicate charging status.
  3. Sensor Preparation: Ensure the flexible probe and filter components are securely attached. The heated diode sensor requires a brief warm-up period after powering on.
Elitech ILD-100H Refrigerant Leak Detector, a handheld device with a flexible probe and a digital display.

Figure 4.1: Elitech ILD-100H ready for setup.

5. Istruzzjonijiet Operattivi

  1. Qawwa Mixgħul: Press the 'ON/OFF' button to power on the device. The TFT screen will illuminate and display a warm-up countdown.
  2. Tisħon: Allow the device to complete its warm-up cycle (typically 20 seconds as seen in image). This ensures the heated diode sensor reaches optimal operating temperature for accurate detection.
  3. Agħżel Sensittività: Use the 'SENS' button to cycle through the sensitivity levels: High (H), Medium (M), and Low (L). Higher sensitivity is recommended for detecting smaller leaks or for initial scanning.
  4. Sejbien ta' tnixxija: Slowly move the flexible probe around suspected leak areas. The device will provide visual alerts on the TFT screen (e.g., bar graph, curve display) and an audible alarm when a leak is detected. The intensity of the alarm and display will increase with higher leak concentrations.
  5. Pinpoint vs. Curve Display: The TFT screen offers two display modes. The 'Pinpoint Display' helps in finding the exact leak location, while the 'Curve Display' assists in quickly identifying the general leak area.
  6. Mute Buzzer: Press the 'MUTE' button to silence the audible alarm if needed.
  7. Itfi: Press and hold the 'ON/OFF' button to power off the device after use.
Elitech ILD-100H display modes showing Pinpoint Display for exact leak location and Curve Display for general leak area.

Figure 5.1: Understanding the Pinpoint and Curve Display modes for leak identification.

Elitech ILD-100H detecting various halogenated refrigerants including HFC, HCFC, CFC, PFC, HFO, and HC types.

Figure 5.2: The ILD-100H's capability to detect a wide range of halogenated refrigerants.

Vidjo 5.1: Overview of Elitech's AI HVAC/R tools, demonstrating the advanced capabilities and applications of their products, including the ILD-100H leak detector in action.

6. Manutenzjoni

  • Tindif: Regularly wipe the exterior of the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Sensor and Filter Maintenance: The device features filter components (as shown in Figure 3.1). Refer to the full user manual (PDF link provided in product data) for specific instructions on cleaning or replacing the sensor and filter to maintain optimal performance.
  • Ħażna: Store the detector in a cool, dry place away from direct sunlight and extreme temperatures when not in use.

7 Issolvi l-problemi

If you encounter issues with your Elitech ILD-100H, consider the following common troubleshooting steps:

  • L-Apparat Mhux Jixgħel: Ensure the battery is fully charged. If the issue persists, try connecting the charger to confirm power supply.
  • Inaccurate Readings/No Detection: Check the sensor and filter for any obstructions or damage. Ensure the device has completed its warm-up cycle. Adjust sensitivity settings to a higher level if necessary.
  • Imġieba Erratika: Ensure the device is not exposed to strong electromagnetic interference. Try restarting the device.

For persistent issues or complex problems, please refer to the comprehensive user manual or contact Elitech customer support.

8. Speċifikazzjonijiet

AttributDettall
BrandElitech
Numru tal-MudellILD-100H
StilHeated Diode Sensor
Sors tal-EnerġijaMħaddma bil-batterija
KulurHeated Diode Sensor Ild-100h
Dimensjonijiet tal-Prodott (P x W x H)1.5" x 3.3" x 7.9"
Piż tal-oġġett2.46 liri
Tip ta 'allarmJinstema'
Umdità Operattiva85 fil-mija
Klassifikazzjoni tat-Temperatura Għolja20 Grad Celsius
Tip tas-SensorIR
MaterjalPlastik
Sensittività massima0.1 oz/yr
Ħin ta' RisponsImmediate (within 1s)
Tip ta 'batterijaLithium Ion (1 Lithium Metal battery included)
Kapaċità tal-batterija3.7V 3000mAh
UżuHVAC systems, refrigerant leak detection
Standards ta' KonformitàEN14624.5AE-162, SAE-2791, SAE-2913, CE
UPC704529988930, 704529989043

9. Garanzija u Appoġġ

The Elitech ILD-100H Refrigerant Leak Detector comes with a garanzija ta 'sena mid-data tax-xiri.

For any technical assistance, product inquiries, or warranty claims, Elitech offers 7x24 customer services. Please refer to the official Elitech website or the full user manual for contact details.

You can also download the complete user manual in PDF format for more detailed information: Niżżel il-Manwal tal-Utent (PDF)

Dokumenti Relatati - ILD-100H

Preview Elitech WJL-6000S Corona Detector Manwal għall-Utent
Manwal tal-utent għad-Detector tal-Korona Elitech WJL-6000S, li jipprovdi struzzjonijiet dettaljati dwar it-tħaddim, id-detezzjoni, is-soluzzjoni tal-problemi, u l-manutenzjoni għad-detezzjoni ta' tnixxija ta' refriġerant f'diversi sistemi.
Preview Elitech ILD Serje Infrared Refriġerant Leak Detector Manwal għall-Utent
Comprehensive user manual for the Elitech ILD series infrared refrigerant leak detectors (ILD-100, ILD-200, ILD-300), covering specifications, operation, maintenance, and features. Learn how to effectively detect refrigerant leaks with this advanced device.
Preview Manwal tal-Utent tad-Ditekter tat-Tnixxijiet bl-Infra-aħmar Elitech ILD-100/ILD-200/ILD-300
Manwal tal-utent għad-ditekters tat-tnixxija tar-refriġerant bl-infra-aħmar tas-serje Elitech ILD (ILD-100, ILD-200, ILD-300). Jipprovdi informazzjoni dettaljata dwar it-tħaddim, l-ispeċifikazzjonijiet, il-karatteristiċi, u l-manutenzjoni għal skoperta preċiża ta' tnixxija tar-refriġerant.
Preview Manwal tal-Utent tad-Ditekter tat-Tnixxija tar-Refriġerant b'Diode Msaħħan Elitech LD-100
Manwal tal-utent għad-Detector tat-Tnixxija tar-Refriġerant b'Diode Msaħħan Elitech LD-100, li jiddeskrivi l-karatteristiċi, l-operat u l-manutenzjoni tiegħu.
Preview Manwal tal-Utent tad-Ditekter tat-Tnixxijiet Elitech IR-200 b'Dijodi Infra-aħmar u Msaħħan
Manwal komprensiv għall-utent għall-Elitech IR-200, ditekter tat-tnixxija b'żewġ sensuri li jinkludi teknoloġija ta' dijodi infra-aħmar u msaħħna. Tgħallem dwar l-ispeċifikazzjonijiet, it-tħaddim, il-manutenzjoni u l-karatteristiċi tiegħu għad-detezzjoni ta' tnixxijiet ta' refriġerant.
Preview Manifold Diġitali Elitech MS-100: Manwal tal-Utent u Speċifikazzjonijiet
Gwida komprensiva għall-manifold diġitali Elitech MS-100, li tkopri l-karatteristiċi tiegħu, l-ispeċifikazzjonijiet tekniċi, it-tħaddim, l-istruzzjonijiet tas-sigurtà, u s-soluzzjoni tal-problemi. Tgħallem kif tuża l-apparat għal kejl tal-pressjoni u t-temperatura, testijiet tat-tnixxija, proċessi tal-vakwu, u r-reġistrazzjoni tad-dejta bl-app Elitech Tools.