VTSYIQI Ultrasonic Flow Meter TL-1-HT User Manual

Model: TL-1-HT | Pipe Size: DN300-6000mm

1. Introduzzjoni

This manual provides essential instructions for the proper installation, operation, and maintenance of the VTSYIQI Ultrasonic Flow Meter TL-1-HT. To ensure accurate measurements and safe operation, please read this manual thoroughly before using the device and retain it for future reference.

The VTSYIQI TL-1-HT is designed for measuring the flow velocity of liquids in pipes ranging from DN300 to DN6000mm using a waterproof clamp-on transducer. It offers high accuracy and bi-directional measurement capabilities.

2. Informazzjoni dwar is-Sigurtà

Osserva l-prekawzjonijiet ta' sigurtà li ġejjin biex tevita korrimenti u ħsara lill-istrument:

  • Tiżgura l-provvista tal-enerġija voltage matches the instrument's requirements (DC8~36V or AC85~264V).
  • Do not operate the device in environments with flammable or explosive gases.
  • Avoid exposing the main unit to excessive moisture or direct water spray, although transducers are waterproof.
  • All wiring should be performed by qualified personnel following local electrical codes.
  • Do not attempt to disassemble or repair the instrument yourself. Contact authorized service personnel for assistance.
  • Handle transducers and cables with care to prevent damage.

3. Prodott Aktarview

3.1 Karatteristiċi ewlenin

  • Eżattezza: ±1%
  • Medda ta' Veloċità: 0 to ±10m/s, bi-directional measurement
  • Daqs tal-pajp: DN300-6000mm (11.81-236.22 inches)
  • Firxa tat-Temperatura: -30°C sa 160°C
  • Kompatibilità Likwida: Single liquids capable of transmitting ultrasound (e.g., water, seawater, sewage, oil).
  • Materjal tal-pajp: Steel, stainless steel, cast iron, copper, PVC, aluminum, glass steel, etc. Liner is allowed.
  • Output tas-Sinjal: 1 way 4-20mA, 1 way OCT pulse, 1 way Relay output
  • Input tas-Sinjal: 3 way 4-20mA input, supports heat measurement via PT100 platinum resistor.
  • Interface: RS485, supports MODBUS protocol.
  • Provvista tal-Enerġija: DC8~36V or AC85~264V

3.2 Komponenti

The VTSYIQI TL-1-HT Ultrasonic Flow Meter system typically includes the following components:

  • Main Flow Meter Unit (with display and control buttons)
  • Waterproof Clamp-on Transducers (TL-1-HT type)
  • Transducer Cables
  • Immuntar Clamps/Straps for Transducers
VTSYIQI Ultrasonic Flow Meter Main Unit Front View

Figura 1: Quddiem view of the VTSYIQI Ultrasonic Flow Meter main unit, showing the display and control buttons (MENU, UP, DOWN, ENT).

VTSYIQI Ultrasonic Flow Meter Main Unit Angled View

Figura 2: Angolat view of the main flow meter unit, highlighting its compact design.

VTSYIQI Ultrasonic Flow Meter with Transducers and Cable

Figure 3: The complete VTSYIQI Ultrasonic Flow Meter system, including the main unit, two clamp-on transducers, and connecting cables.

VTSYIQI Ultrasonic Flow Meter Components with Clamps

Figure 4: All components laid out, showing the main unit, transducers, cables, and pipe mounting clamps.

4. Setup u Installazzjoni

4.1 Installazzjoni tat-transducer

The TL-1-HT uses clamp-on transducers, which are installed on the outer surface of the pipe. Proper installation is crucial for accurate measurements.

  1. Agħżel Post Xieraq: Choose a straight pipe section free from elbows, valves, or pumps for a distance of at least 10 pipe diameters upstream and 5 pipe diameters downstream.
  2. Prepare the Pipe Surface: Clean the outer surface of the pipe thoroughly to remove any rust, paint, or debris. A smooth surface ensures good acoustic coupling.
  3. Apply Coupling Gel: Apply a generous amount of ultrasonic coupling gel to the contact surface of both transducers and the pipe surface where they will be mounted.
  4. Mount Transducers: Position the transducers on the pipe according to the specified mounting method (Z-method, V-method, etc., depending on pipe size and liquid). Ensure they are securely clamped to prevent movement. The distance between transducers is critical and should be calculated based on pipe diameter, material, and liquid type. Refer to the instrument's internal setup menu for precise spacing.
  5. Qabbad Kejbils: Connect the transducer cables to the main unit's designated ports (TX1, RX1, TX2, RX2 if applicable). Ensure connections are secure and waterproof.

4.2 Wiring Diagram and Power Supply

The main unit features multiple terminal blocks for power, signal input/output, and communication. Refer to the images below for terminal identification.

VTSYIQI Ultrasonic Flow Meter Top Terminal Connections

Figura 5: Fuq view of the main unit showing terminal connections for transducers (TX1, T1, GND, TX2, T2) and signal outputs (A15, A14, A13, OCT1-, OCT1+, RLY-, RLY+).

VTSYIQI Ultrasonic Flow Meter Bottom Terminal Connections

Figura 6: Qiegħ view of the main unit showing terminal connections for power (24V+, 24V-), RS485 communication (485+, 485-), analog input (AO-IN), and other inputs (UP+, UP-, DN+, DN-, GND).

Konnessjoni tal-Enerġija: Connect the power supply (DC8~36V or AC85~264V) to the designated "24V+" and "24V-" terminals. Ensure correct polarity for DC power.

Output tas-Sinjal:

  • Ħruġ 4-20mA: Connect to the 4-20mA output terminals.
  • OCT Pulse Output: Connect to the OCT1- and OCT1+ terminals.
  • Ħruġ tar-Relay: Connect to the RLY- and RLY+ terminals.

Input tas-Sinjal: The 3-way 4-20mA input can be used for external signals, such as PT100 platinum resistors for heat measurement. Connect these to the A13, A14, A15 terminals as per your application requirements.

Komunikazzjoni RS485: Connect RS485 communication lines to the "485+" and "485-" terminals for MODBUS communication with external systems.

5. Istruzzjonijiet Operattivi

5.1 Operazzjoni Bażika u Navigazzjoni tal-Menù

The main unit features a display and four control buttons: MENU, UP (▲), DOWN (▼), and ENT (Enter).

  • MENU: Press to enter the main menu or go back to the previous menu level.
  • UP (▲) / DOWN (▼): Uża biex tiskrollja mill-għażliet tal-menù jew taġġusta l-valuri tal-parametri.
  • ENT: Agħfas biex tikkonferma għażla jew tidħol f'submenu.

Upon powering on, the device will typically display the current flow rate. Use the MENU button to access various settings and diagnostic screens.

5.2 Konfigurazzjoni Inizjali

After installation, configure the flow meter with the correct pipe parameters:

  1. Dijametru tal-pajp: Enter the outer diameter of the pipe.
  2. Materjal tal-pajp: Select the material of the pipe from the predefined list. This affects the sound speed.
  3. Liner Material (if applicable): If the pipe has a liner, specify its material and thickness.
  4. Tip ta' Likwidu: Select the type of liquid being measured.
  5. Transducer Spacing: The meter will calculate the optimal transducer spacing based on the entered parameters. Adjust the physical transducer position on the pipe to match this calculated distance.
  6. Kalibrazzjoni Żero: Perform a zero calibration when there is no flow in the pipe to ensure accurate readings.

Detailed instructions for each menu option are available within the device's firmware. Consult the on-screen prompts for guidance.

6. Manutenzjoni

Regular maintenance ensures the longevity and accuracy of your VTSYIQI Ultrasonic Flow Meter TL-1-HT.

  • Clean Transducers: Periodically inspect and clean the transducer surfaces and the pipe contact area. Reapply coupling gel if it has dried out or been disturbed.
  • Spezzjona Kejbils u Konnessjonijiet: Check all cables for signs of wear or damage. Ensure all electrical connections are secure and free from corrosion.
  • Kontroll Ambjentali: Ensure the main unit is protected from extreme temperatures, direct sunlight, and excessive vibration.
  • Kalibrazzjoni mill-ġdid: Depending on application requirements and local regulations, periodic recalibration may be necessary to maintain measurement accuracy.

7 Issolvi l-problemi

This section addresses common issues you might encounter with the flow meter.

ProblemaKawża PossibbliSoluzzjoni
No flow reading or unstable reading
  • Poor transducer coupling
  • Incorrect transducer spacing
  • Air bubbles or solids in the liquid
  • Parametri tal-pajpijiet mhux korretti mdaħħla
  • Damaged transducer or cable
  • Reapply coupling gel and ensure firm contact.
  • Verify and adjust transducer spacing according to the meter's calculation.
  • Check for air pockets or excessive solids; relocate transducers if necessary.
  • Review and correct pipe diameter, material, and liquid type settings.
  • Inspect transducers and cables for damage; replace if faulty.
Inaccurate flow reading
  • Incorrect pipe parameters
  • Turbulence in the flow
  • Drift punt żero
  • Double-check all configuration settings.
  • Ensure transducers are installed on a sufficiently long straight pipe section.
  • Wettaq kalibrazzjoni żero.
Il-wiri huwa vojt
  • Ebda provvista ta 'enerġija
  • Konnessjoni tal-enerġija difettuż
  • Verify power source is active.
  • Check power wiring to the main unit.

If the problem persists after attempting these solutions, contact VTSYIQI customer support for further assistance.

8. Speċifikazzjonijiet

Eżattezza±1%
Firxa tal-Veloċità0 to ±10m/s, Bi-directional measurement
Daqs tal-pajpDN300-6000mm (11.81-236.22 inches)
Firxa tat-Temperatura-30°C sa 160°C
Tip ta 'LikwiduSingle liquid capable of transmitting ultrasound (e.g., water, seawater, sewage, oil)
Materjal tal-pajpSteel, stainless steel, cast iron, copper, PVC, aluminum, glass steel, etc. (Liner allowed)
Ħruġ tas-Sinjal1 way 4-20mA, 1 way OCT pulse, 1 way Relay output
Input Signal3 way 4-20mA input (for heat measurement via PT100 platinum resistor)
InterfaceRS485, supports MODBUS
Provvista tal-EnerġijaDC8~36V or AC85~264V
Dimensjonijiet tal-Pakkett15.75 x 7.87 x 3.94 pulzieri
Piż4.41 Liri
ManifatturVTSYIQI

9. Garanzija u Appoġġ

VTSYIQI products are manufactured to high-quality standards. For specific warranty terms and conditions, please refer to the documentation provided at the time of purchase or contact VTSYIQI customer service.

For technical support, troubleshooting assistance, or service inquiries, please contact your authorized VTSYIQI distributor or visit the official VTSYIQI store online: VTSYIQI Store.

Dokumenti Relatati - TL-1-HT

Preview Gwida għall-Operazzjoni tal-Miter tal-Attività tal-Ilma
Istruzzjonijiet pass pass għat-tħaddim ta' Miter tal-Attività tal-Ilma VTSYIQI, inklużiampil-proċeduri ta' preparazzjoni u kejl għall-ittestjar tal-ikel.
Preview Gwida għall-Kalibrazzjoni u Dejta dwar l-Umdità Relattiva għall-Miters tal-Attività tal-Ilma VTSYIQI
Proċedura dettaljata ta' kalibrazzjoni għal miters tal-attività tal-ilma li jużaw soluzzjonijiet ta' melħ saturat, inklużi tabelli komprensivi ta' dejta dwar l-umdità relattiva f'temperaturi varji għal diversi melħ. Referenza essenzjali għall-prodotti ta' HeFei Vetus Electronic Technology Co., Ltd.
Preview Manwal tal-Utent u Istruzzjonijiet għat-Tħaddim tal-Miter tal-Attività tal-Ilma Intelliġenti HD-6
Manwal komprensiv għall-utent għall-HD-6 Smart Water Activity Meter minn VTSYIQI. Ikopri speċifikazzjonijiet tekniċi, installazzjoni, tħaddim, kalibrazzjoni, setup tas-softwer, issolvi l-problemi, u avviżi importanti għal kejl preċiż tal-attività tal-ilma.
Preview Miter tal-Attività tal-Ilma VTSYIQI: Gwida għall-Utent u l-Aħjar Prattiki tal-Kejl
Din il-gwida tipprovdi struzzjonijiet essenzjali għat-tħaddim tal-VTSYIQI Water Activity Meter, inklużi l-mudelli VTS-160A u WA-18CA. Tgħallem dwar it-tqegħid xieraq tal-cassette, l-iżgurar ta' ambjent ta' kejl issiġillat, u l-interpretazzjoni tar-riżultati għal ittestjar preċiż tal-attività tal-ilma fi prodotti tal-ikel.
Preview Sewwieq Sonic MODBUS WALL-UFM Miter tal-Fluss Ultrasoniku: Istruzzjonijiet għat-Tħaddim
Istruzzjonijiet komprensivi dwar it-tħaddim għas-Sonic Driver MODBUS WALL-UFM clamp-on miter tal-fluss ultrasoniku, li jkopri l-installazzjoni, il-konfigurazzjoni, il-kejl, id-dijanjostika, u s-soluzzjoni tal-problemi.
Preview Skeda tad-Data tal-Miter tal-Fluss Ultrasoniku SIL ta' Panametrics PanaFlow HT għal-Likwidi
Skeda tad-dejta dettaljata għall-Panametrics PanaFlow HT, miter tal-fluss ultrasoniku b'klassifikazzjoni SIL għal-likwidi. Il-karatteristiċi jinkludu ċertifikazzjoni SIL, kejl ta' temperatura għolja/baxxa, u teknoloġija tal-ħin ta' transitu. Tinkludi speċifikazzjonijiet, applikazzjonijiet, u informazzjoni dwar l-ordnijiet.