1. Introduzzjoni
This manual provides comprehensive instructions for the VOTRONIC VCC 1212-70 B2B Charging Converter. It covers installation, operation, and maintenance to ensure optimal performance and longevity of your battery system. The VCC 1212-70 is designed for universal use with 12V onboard batteries, including traditional lead-acid, lead-gel, AGM, and modern Lithium-LiFePO4 technologies. Its selectable charging programs ensure a complete, fast, and gentle charge from any state of charge, while also maintaining battery health. The converter automatically supplies power to connected 12V consumers, even under high load, and its automatic power control ensures vehicle starting capability and system safety.
The VCC 1212-70 is a non-galvanically isolated B2B charge booster designed to charge 12V service batteries from a 12V alternator/starter battery. It delivers a charging current of 70A and is suitable for recommended battery capacities between 100-460 Ah.
2. Istruzzjonijiet tas-Sigurtà
Please read and understand all safety instructions before installing or operating the device. Failure to follow these instructions may result in injury, damage to the device, or other property damage.
- Persunal kwalifikat: Installation and maintenance should only be performed by qualified personnel familiar with electrical systems and battery handling.
- Periklu ta' Xokk Elettriku: Do not open the device. There are no user-serviceable parts inside. Disconnect all power sources before making any connections or performing maintenance.
- Sigurtà tal-batterija: Batteries can produce explosive gases. Ensure adequate ventilation during charging. Avoid sparks and open flames near batteries. Wear appropriate personal protective equipment (PPE), including eye protection.
- Protezzjoni tal-kurrent żejjed: Ensure proper fusing is installed on all input and output lines as specified in the installation section.
- Temperatura: Do not expose the device to extreme temperatures, direct sunlight, or moisture. Ensure sufficient airflow around the unit for cooling.
- Vol korretttage: Ensure the input and output voltages match the specifications of your system (12V to 12V).
3. Prodott Aktarview
The VOTRONIC VCC 1212-70 is a compact and efficient charging converter designed to optimize the charging of your service battery while driving. It features high-frequency switch-mode technology for a lightweight and robust design.

Figura 1: Quddiem view of the VOTRONIC VCC 1212-70 Charging Converter, showing connection terminals, display, and status LEDs.
Karatteristiċi ewlenin:
- Iċċarġjar ottimizzat: Ensures optimal and rapid charging of the service battery from the alternator during driving.
- Voltage Kumpens: Fully compensates for line losses and alternator voltage fluctuations, including those from Euro 6 intelligent alternators.
- Kompatibilità ma' Batteriji Multipli: Supports lead-acid, lead-gel, AGM, and LiFePO4 batteries with selectable charging programs.
- Operazzjoni Awtomatika: Automatically activated by the vehicle's alternator when the engine is running. Prevents discharge of batteries when the engine is off.
- Protezzjonijiet Integrati: Multiple protections against overcharge, overheating, overvoltage, short circuits, and reverse discharge.
- Sensor tat-temperatura: Includes a battery temperature sensor for temperature-compensated charging of lead batteries and low-temperature protection for LiFePO4 batteries.
- Simultaneous Consumption: Allows simultaneous power supply to 12V consumers while charging the service battery.
4. Setup u Installazzjoni
Proper installation is critical for the safe and efficient operation of the VCC 1212-70. Refer to the wiring diagram provided with the product for detailed connection instructions.
4.1 Post tal-Immuntar
- Mount the converter in a dry, well-ventilated area, protected from moisture, dust, and direct heat.
- Ensure sufficient space around the unit for proper heat dissipation.
- Mount securely using appropriate fasteners to prevent movement during vehicle operation.
4.2 Konnessjonijiet elettriċi
All connections must be made with appropriate cable gauges to handle the 70A current. Use high-quality crimp terminals and ensure secure connections.
- Skonnettja Batteriji: Before making any connections, disconnect the negative terminals of both the starter battery and the service battery.
- Input Connection (Starter Battery): Connect the input terminals (Start IN) of the VCC 1212-70 to the starter battery. Ensure an appropriate fuse (e.g., 80A-100A) is installed on the positive line as close to the starter battery as possible.
- Output Connection (Service Battery): Connect the output terminals (Bord OUT) of the VCC 1212-70 to the service battery. Install an appropriate fuse (e.g., 80A-100A) is installed on the positive line as close to the service battery as possible.
- Konnessjoni mal-art: Connect the ground terminals (Vs-, Vb-) to a common ground point or directly to the negative terminals of the respective batteries.
- D+ Signal (Optional but Recommended): Connect the D+ terminal to the alternator's D+ signal or an ignition-switched positive source. This ensures the converter only operates when the engine is running.
- Sensor tat-temperatura: Connect the included battery temperature sensor to the designated terminals (T). Mount the sensor directly on the service battery for accurate temperature readings. This is crucial for optimal charging of lead-acid batteries and protection of LiFePO4 batteries.
4.3 Għażla tat-Tip ta' Batterija
The VCC 1212-70 features selectable charging programs for different battery types. Refer to the product's specific dip switch or button configuration for selecting the correct battery type (Lead-Acid, Gel, AGM1, AGM2, LiFePO4). Selecting the correct battery type is essential for proper charging and battery longevity.
5. Istruzzjonijiet Operattivi
The VOTRONIC VCC 1212-70 operates largely automatically once correctly installed and configured.
5.1 Operazzjoni Awtomatika
- When the vehicle engine starts and the alternator provides sufficient voltage, the VCC 1212-70 will automatically activate and begin charging the service battery.
- The intelligent microprocessor-controlled charging ensures a rapid and gentle charge according to the selected battery type (IU1oU2oU3 charging characteristic).
- Dynamic charging time calculation automatically adjusts to the battery's state of charge.
- If the engine is switched off, the converter will cease operation, preventing discharge of the starter battery.
5.2 Indikaturi tal-Istat
The device features LED indicators to show its operational status:
- LED tal-qawwa: Jindika li l-apparat huwa mixgħul.
- Start IN LED: Tindika voltage is detected from the starter battery/alternator.
- Bord OUT LED: Tindika voltage is being supplied to the service battery.
- Main Charge LED: Indicates the battery is in the main charging phase.
- Battery Full LED: Indicates the service battery is fully charged and in maintenance mode.
5.3 Simultaneous Consumption
The VCC 1212-70 allows 12V consumers to be powered simultaneously from the service battery while it is being charged. The device manages the power distribution to ensure both charging and consumption needs are met without compromising battery health or vehicle starting capability.
6. Manutenzjoni
The VOTRONIC VCC 1212-70 is designed for reliable operation with minimal maintenance. Regular checks can help ensure its longevity and performance.
- Spezzjoni Viżwali: Periodically inspect the device and its connections for any signs of damage, corrosion, or loose wiring.
- Indafa: Żomm l-unità nadifa u ħielsa mit-trab u l-fdalijiet. Uża drapp niexef u artab għat-tindif. Tużax prodotti tat-tindif likwidi.
- Ventilazzjoni: Ensure that the ventilation openings are not obstructed to allow for proper cooling.
- Terminali tal-Batterija: Check battery terminals for cleanliness and tightness. Corroded terminals can impede charging efficiency.
7 Issolvi l-problemi
If the VCC 1212-70 is not functioning as expected, review il-kwistjonijiet komuni li ġejjin qabel ma tikkuntattja l-appoġġ.
- No Charging / Power LED Off:
- Check all input and output fuses. Replace if blown.
- Iċċekkja li l-konnessjonijiet elettriċi kollha huma siguri u ħielsa mill-korrużjoni.
- Ensure the starter battery voltage is sufficient (engine running).
- Check the D+ signal connection (if used) for proper activation.
- Iċċarġjar bil-mod:
- Confirm the correct battery type is selected on the converter.
- Check cable gauges; undersized cables can lead to voltage drop and reduced charging current.
- Ensure the temperature sensor is correctly installed on the service battery.
- Is-sħana żejda:
- Ensure adequate ventilation around the unit. Clear any obstructions from cooling fins.
- Verify the ambient temperature is within the operating range.
- LiFePO4 Battery Not Charging Below 0°C:
- The VCC 1212-70, when set to LiFePO4, may significantly reduce charging current below 0°C to protect the battery. This is a safety feature. If your LiFePO4 battery has integrated heating mats, ensure they are functioning. The converter's temperature sensor will prevent charging if the battery temperature is too low for safe LiFePO4 charging.
If problems persist after following these steps, please contact VOTRONIC customer support.
8. Speċifikazzjonijiet Tekniċi
| Speċifikazzjoni | Valur |
|---|---|
| Brand | VOTRONIC |
| Numru tal-Mudell | VCC 1212-70 |
| Input Voltage | 12 Volts |
| Ħruġ Voltage | 12 Volts |
| Kurrent tal-Iċċarġjar | 70 A |
| Kapaċità Rakkomandata tal-Batterija | 100 - 460 Ah |
| Dimensjonijiet (D x W x H) | 7.1 x 16 x 23.5 ċm |
| Piż tal-oġġett | 1.3 Kilogrammi |
| Kulur | Abjad |
| Ċertifikazzjonijiet | CE, TÜV |
9. Garanzija u Appoġġ
For warranty information, please refer to the documentation provided with your purchase or contact your retailer. VOTRONIC products are designed for durability and performance. In case of technical issues or questions not covered in this manual, please contact VOTRONIC customer support or an authorized service center for assistance.
Manifattur: VOTRONIC






