Riello FD01

Riello FD01 Photoelectric Cell Instruction Manual

Model: FD01 | Brand: Riello

1. Prodott Aktarview

The Riello FD01 Photoelectric Cell is a critical component designed for use in Riello oil burners. Its primary function is to detect the presence of a flame, ensuring safe and efficient operation of the heating system. This cell acts as a sensor, signaling the control unit about the combustion status. It is an essential spare part for maintaining the functionality of compatible Riello burner models.

Riello FD01 Photoelectric Cell with wires and connector

Figura 1.1: Riello FD01 Photoelectric Cell. This image displays the main component with its attached wiring and connector, ready for installation.

2. Kompatibilità

The Riello FD01 Photoelectric Cell is compatible with a range of Riello burner models. Please verify your burner model number against the list below to ensure proper fit and function. This component is specifically designed to work in conjunction with the MO550 BWG or MO550 MWG control units.

Compatible Burner Models:

Nota: Compatibility is only ensured when used in conjunction with the MO550 BWG or MO550 MWG control unit.

3. Setup u Installazzjoni

Installation of the Riello FD01 Photoelectric Cell involves working with electrical and fuel systems. For safety and proper function, installation and replacement procedures must be performed by a qualified and certified technician. Incorrect installation can lead to equipment damage, fire, or personal injury.

3.1 Replacement Procedure (General Guidelines)

  1. Is-Sigurtà l-Ewwel: Ensure the burner and heating system are completely powered off and disconnected from the main electricity supply. Close any fuel supply valves.
  2. Aċċess: Carefully open the burner housing to access the existing photoelectric cell.
  3. Skonnettjar: Disconnect the wiring from the old photoelectric cell and carefully remove it from its mounting. Note the orientation and connection points.
  4. Installazzjoni: Insert the new Riello FD01 Photoelectric Cell into the designated slot, ensuring it is securely seated. Connect the wiring according to the burner's electrical diagram.
  5. Reassembly & Testing: Close the burner housing. Restore power and fuel supply. Perform a functional test of the burner to ensure the new cell is operating correctly and detecting the flame.
Riello FD01 Photoelectric Cell from a different angle, showing the sensor end

Figura 3.1: Riello FD01 Photoelectric Cell, side view. This image provides a clearer view of the sensor's body and the integrated mounting features.

3.2 Specific Replacement Note for 3007492

If the existing photo resistance with part number 3007492 is found to be defective, it is recommended that the entire control unit be replaced. In such cases, the conversion kit 20146982 (which includes the MO550 BWG control unit and the FD01 photo resistance) is advised for a complete and compatible solution.

4. Istruzzjonijiet Operattivi

The Riello FD01 Photoelectric Cell operates automatically as part of the burner's control system. It continuously monitors the flame during burner operation. There are no direct user operating controls for this component. Its function is entirely passive, providing feedback to the burner's control unit.

5. Manutenzjoni

The Riello FD01 Photoelectric Cell generally requires minimal maintenance. However, as part of routine burner servicing, a qualified technician should inspect the cell for any signs of damage or excessive soot accumulation on its sensing surface. A clean sensing surface is crucial for accurate flame detection.

Riello FD01 Photoelectric Cell with wires and connector, showing the connector in detail

Figura 5.1: Riello FD01 Photoelectric Cell, connector view. This image highlights the electrical connector, which is crucial for proper wiring during installation.

6 Issolvi l-problemi

If your oil burner is experiencing issues related to flame detection or failure to ignite, the photoelectric cell may be a contributing factor. Always consult a qualified technician for diagnosis and repair.

6.1 Kwistjonijiet Komuni u Soluzzjonijiet

Importanti: Do not attempt to repair the photoelectric cell or control unit yourself. Contact a professional heating technician for all diagnostic and repair work.

7. Speċifikazzjonijiet

BrandRiello
MudellFD01
Numru tal-Parti (ASIN)B07H32C3P6
FunzjoniFlame detection for oil burners
Nota ta' KompatibbiltàRequires MO550 BWG or MO550 MWG control unit for full compatibility with listed burner models.
ManifatturRiello

For detailed technical drawings or specific electrical parameters, please refer to the official Riello documentation for your specific burner model or contact Riello customer support.

8. Garanzija u Appoġġ

Information regarding the warranty for the Riello FD01 Photoelectric Cell is not provided within this instruction manual. For warranty details, technical support, or to locate authorized service centers, please contact your original point of purchase or visit the official Riello website. Always provide your product model and serial number when seeking support.

Dokumenti Relatati - FD01

Preview Manwal tal-Installazzjoni u l-Manutenzjoni tal-Burner taż-Żejt Ħafif Riello RG2D
Gwida komprensiva għall-burner taż-żejt ħafif Riello RG2D, li tkopri l-installazzjoni, it-tħaddim, il-manutenzjoni, u s-soluzzjoni tal-problemi. Tinkludi speċifikazzjonijiet tekniċi, dijagrammi, u struzzjonijiet ta' sigurtà.
Preview Lista u Dijagramma tal-Partijiet tal-Burner taż-Żejt Riello Gulliver RG2F
Lista dettaljata tal-ispare parts u dijagramma tal-komponenti għall-burner taż-żejt ħafif Riello Gulliver RG2F (Mudell 377T1, Kodiċi 3737770), inklużi n-numri tal-partijiet u d-deskrizzjonijiet bl-Ingliż.
Preview Manwal tal-Installazzjoni tal-Burners taż-Żejt Residenzjali Riello Serje 40 F3 & F5
Dan il-manwal jipprovdi struzzjonijiet dettaljati għall-installazzjoni għar-Riello 40 Series Residential Oil Burners, mudelli F3 u F5. Ikopri l-identifikazzjoni tal-komponenti, is-setup, l-immuntar, il-konnessjonijiet elettriċi, it-tqegħid taż-żennuni, u l-proċeduri ta' aġġustament. Il-manwal huwa maħsub għal applikazzjonijiet ta' retrofit u jinkludi dejta teknika, speċifikazzjonijiet, u listi ta' spare parts.
Preview Priročnik za namestitev, uporabo in vzdrževanje gorilnika RIELLO Gulliver RG1NR na plinsko olje
Ta dokument vsebuje podrobna navodila za namestitev, uporabo, vzdrževanje in odpravljanje napak enostopenjskega gorilnika RIELLO Gulliver RG1NR na plinsko olje, vključno s tehničnimi podatki, varnostnimi predpisi ožprav postol predpisje ožavv.
Preview Riello 40 BF Single StagManwal ta' Installazzjoni u Tħaddim tal-Burner taż-Żejt
Manwal komprensiv għall-installazzjoni u t-tħaddim tar-Riello 40 BF single-stagBurner taż-żejt elettroniku, li jkopri speċifikazzjonijiet tekniċi, proċeduri ta' installazzjoni, dijagrammi tal-wajers, issolvi l-problemi, u spare parts.
Preview Manwal tal-Installazzjoni tal-Burner taż-Żejt Residenzjali Riello 40 Series F3 & F5
Manwal komprensiv tal-installazzjoni għall-berners taż-żejt residenzjali Riello tas-Serje 40, mudelli F3 u F5. Ikopri dejta teknika, identifikazzjoni tal-komponenti, setup, immuntar, konnessjonijiet elettriċi, konfigurazzjoni tal-linja taż-żejt, tneħħija tal-pompa, aġġustamenti, u spare parts.