1. Introduzzjoni
This manual provides comprehensive instructions for the installation, operation, and maintenance of the FAAC Lecteur Autonomo Resist Tps Sa. This autonomous reader is designed for secure access control applications, typically used with gate or door automation systems. Please read this manual thoroughly before installation and use to ensure proper function and safety.
2. Informazzjoni dwar is-Sigurtà
- L-installazzjoni għandha titwettaq minn persunal kwalifikat skont il-kodiċijiet u r-regolamenti elettriċi lokali.
- Disconnect power to the access control system before performing any installation, maintenance, or wiring procedures.
- Tesponix l-apparat għal temperaturi estremi, umdità, jew sustanzi korrużivi.
- Kun żgur li l-konnessjonijiet kollha huma siguri u iżolati sew biex tevita short circuits.
- Żomm il-materjali tal-ippakkjar fejn ma jintlaħaqx mit-tfal.
3. Kontenut tal-Pakkett
Iċċekkja li l-komponenti kollha huma preżenti qabel tibda l-installazzjoni:
- FAAC Lecteur Autonomo Resist Tps Sa unit
- Mounting screws and anchors (typically included)
- Wiring terminals (if applicable)
4. Setup u Installazzjoni
4.1 Komponent Aktarview

Stampa 1: Quddiem view of the FAAC Lecteur Autonomo Resist Tps Sa. The unit features a numeric keypad (0-9), 'X' for clear/cancel, and 'E' for enter/confirm. The FAAC logo is centrally located, and small indicator lights are visible above it.
4.2 Immuntar tal-Unità
- Choose a suitable mounting location near the access point, ensuring it is protected from direct heavy rain and easily accessible.
- Mark the drilling points on the wall using the unit's backplate as a template.
- Ħaffer toqob u daħħal ankri tal-ħajt xierqa.
- Secure the unit to the wall using the provided screws.
4.3 Konnessjonijiet tal-Wiring
Refer to the wiring diagram provided with your specific gate/door automation system for detailed connections. General wiring steps include:
- Connect the power supply (typically 12-24V AC/DC) to the designated terminals on the reader.
- Connect the output terminals of the reader to the control input of your gate or door opener. This output typically triggers the opening mechanism upon successful code entry.
- Kun żgur li l-konnessjonijiet kollha huma ssikkati u iżolati.
4.4 Initial Programming
The initial programming involves setting up master codes and user access codes. Consult the specific programming instructions that came with your unit, as procedures can vary slightly by firmware version. Typically, this involves:
- Entering a default master code to access programming mode.
- Adding new user codes (e.g., 4-8 digits long).
- Exiting programming mode to save changes.
5. Operazzjoni
5.1 Entering an Access Code
To activate the access control system:
- Press the numeric keys to enter your valid access code.
- Press the 'E' (Enter) button to confirm the code.
- If the code is correct, the indicator light will typically illuminate green, and the gate/door will activate.
5.2 Correcting an Entry
If you make a mistake while entering the code, press the 'X' (Clear) button to clear the current entry and re-enter the code.
5.3 Dwal Indikaturi
The small indicator lights above the FAAC logo provide feedback:
- Dawl aħdar: Indicates a valid code entry and successful activation.
- Dawl aħmar: Indicates an invalid code entry or an error.
- Amber/Yellow Light: May indicate programming mode or a specific status depending on the model.
6. Manutenzjoni
- Tindif: Clean the keypad surface periodically with a soft, damp drapp. Tużax tindif jew solventi li joborxu.
- Spezzjoni: Regularly inspect the unit for any signs of damage, loose connections, or wear.
- Aġġornamenti tal-Firmware: If applicable, consult FAAC support for information on firmware updates.
7 Issolvi l-problemi
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| L-unità ma tixgħelx. | L-ebda provvista tal-enerġija jew wajers mhux korretti. | Check power connections and ensure correct voltage. Verify wiring to the power source. |
| Code entered, but gate/door does not open. | Incorrect code, output wiring issue, or gate/door opener fault. | Ensure the correct code is entered. Check wiring between the reader and the gate/door opener. Test the gate/door opener independently. |
| Red indicator light illuminates after code entry. | Invalid access code. | Re-enter the correct access code. If the issue persists, verify the code in programming mode. |
| Il-buttuni ma jirrispondux. | Physical damage or internal fault. | Inspect for visible damage. If unresponsive, contact FAAC support for assistance. |
8. Speċifikazzjonijiet
- Ditta: FAAC
- Numru tal-Mudell: 403139
- Tip ta' Prodott: Autonomous Reader
- Piż tal-Pakkett: 500 g
- Dimensjonijiet tal-pakkett: 100.0 L x 100.0 H x 50.0 W (millimeters)
- ASIN: B07GZ16ZXH
9. Informazzjoni dwar Garanzija
Information regarding the warranty for the FAAC Lecteur Autonomo Resist Tps Sa is not available in the provided product details. Please refer to your purchase documentation or contact your retailer or FAAC directly for warranty terms and conditions.
10. Appoġġ u Kuntatt
For further assistance, technical support, or inquiries regarding your FAAC Lecteur Autonomo Resist Tps Sa, please contact FAAC customer service or your authorized FAAC dealer. You can typically find contact information on the official FAAC websit (www.faac.com).





