1. Prodott Aktarview

The SMARTGEN HGM93XX MPU(CAN) series genset controllers are designed for comprehensive genset automation and monitoring. They facilitate automatic start/stop operations, data measurement, alarm protection, and "three remote" functions: remote control, remote measuring, and remote communication.

This controller features a large Liquid Crystal Display (LCD) with selectable language interfaces, including English and Chinese, ensuring ease of operation and reliability. The HGM93XX MPU(CAN) series utilizes 32-bit micro-processor technology for precise parameter measurement, fixed value adjustment, time setting, and threshold adjustment. Most parameters can be configured via the front panel, while all parameters can be adjusted and monitored using a PC via the USB port or RS485 port. Its compact structure, simple connections, and high reliability make it suitable for a wide range of automatic genset control systems.

Karatteristiċi ewlenin:

  • Equipped with an ARM-based 32-bit SCM for highly integrated hardware and enhanced reliability.
  • Features a 480x272 TFT LCD with backlight and multilingual interface (English, Chinese, etc.) which can be chosen at the site, making commissioning convenient for factory personnel.
  • Improved LCD wear-resistance and scratch resistance due to a hard screen acrylic.
  • Silicon panel and pushbuttons designed for optimal operation in high-temperature environments.
  • RS485 communication port enables remote control, measuring, and communication via ModBus protocol (requires RS485 communication port).
  • SMS (Short Message Service) function for generator status and alarm notifications (requires SMS/GSM module).
  • CANBUS port for communication with J1939 gensets, allowing monitoring of engine data (water temperature, oil pressure, fuel consumption, etc.) and control functions.
  • Suitable for 3-phase 4-wire, 3-phase 3-wire, single phase 2-wire, and 2-phase 3-wire systems with voltage 120/240V u frekwenza 50/60Hz.
  • Collects and displays 3-phase voltage, current, power parameters, and frequency of generator or mains.
  • Monitors load, current (IA, IB, IC), active power (kW), reactive power (kvar), apparent power (kVA), power factor (PF), accumulated total generator power (kWh, kvarh, kVAh), and earth current (A).
  • Comprehensive protection for mains and generator against over/under voltage, over/under frequency, phase sequence wrong, and over/reverse power.
  • Includes 3 fixed analog sensors (temperature, oil pressure, fuel level) and 2 flexible sensors for temperature, oil pressure, or level.
  • Precision measurement and display of engine parameters: Temp. (WT) in °C/°F, Oil pressure (OP) in kPa/psi/bar, Fuel level (FL) in %, Speed (SPD) in r/min, Battery Voltage (VB) in V, Charger Voltage (VD) in V.
  • Hour count (HC) up to 65535 hours; Start times up to 65535 times.
  • Automatic start/stop of genset, ATS (Auto Transfer Switch) control with perfect failure indication and protection.
  • All output ports are relay-out.
  • Parameters can be modified and stored in internal FLASH memory, adjustable via PC (USB or RS485).
  • Multiple curves for temperature, oil pressure, fuel level can be used, and users can define sensor curves.
  • Multiple crank disconnect conditions (generator frequency, speed sensor, oil pressure).
  • Event log, real-time clock, scheduled start & stop generator functions.
  • PLC (programmable logic control) function for user-defined specific functions.
  • Il-wallpaper tal-logon u l-ħin tal-wiri huma definiti mill-utent.
  • Can be used on pumping units and as an indicating instrument.
  • Maintenance function with warning or shutdown actions.
  • All parameters use digital adjustment for higher reliability.
  • Waterproof security level IP55 due to rubber seal between controller enclosure and panel fascia.
  • Metal fixing clips for high-temperature environments.
  • Modular design, self-extinguishing ABS plastic enclosure, pluggable connection terminals, and embedded installation.
  • Accumulative total run time and total electric energy of A and B, resettable by users.

2. Module Comparison (HGM93XX MPU(CAN) Series)

The HGM93XX series offers different models with varying functionalities. The table below highlights the key differences between the HGM9310MPU and HGM9320MPU models, as well as their CAN bus variants.

Comparison table for HGM93XX MPU(CAN) series controllers

Immaġni: A comparison table detailing features across HGM9310MPU, HGM9320MPU, HGM9310CAN, and HGM9320CAN models, including LCD dimension, AMF, input/output port numbers, sensor numbers, schedule function, RS485, GSM, J1939, USB, real-time clock, and event log.

HGM93XX MPU(CAN) Series Feature Comparison
OġġettHGM9310MPUHGM9320MPUHGM9310CANHGM9320CAN
Dimensjoni LCD4.3" (480 x 272 Pixel)
AMF
Input Numru tal-Port8888
Numru tal-Port tal-Output8888
Numru tas-sensor5555
Neutral current (earth)
Funzjoni tal-iskeda
RS485
GSM
J1939
USB
Arloġġ f'ħin reali
Ġurnal tal-avvenimenti

Nota: (1) Two of the output ports are fixed: start output and fuel output. (2) The analog sensors are composed by 3 fixed sensors (temperature, pressure, fuel level) and 2 flexible sensors.

3. Setup u Installazzjoni

Proper installation is crucial for the safe and effective operation of the HGM9310MPU controller. This section provides general guidelines. Always refer to the detailed wiring diagrams and safety instructions provided in the complete manual for specific installation procedures.

Typical application wiring diagram for HGM9310MPU(CAN) controller

Immaġni: A detailed wiring diagram illustrating the typical application of the HGM9310MPU(CAN) controller, showing connections for generator, load, battery, starter motor, fuel, charge alternator, engine temp, oil pressure, level, auxiliary inputs/outputs, USB, and GSM.

Passi ta' Installazzjoni (Ġenerali):

  1. Immuntar: Securely mount the controller in a suitable enclosure, ensuring adequate ventilation and protection from environmental elements. The controller uses metal fixing clips for embedded installation.
  2. Provvista tal-Enerġija: Connect the DC power supply (DC8.0V to DC35.0V) to the designated terminals. Ensure correct polarity.
  3. Generator and Mains Connections: Connect the generator and mains voltage inputs according to the wiring diagram. The controller supports 3-phase 4-wire, 3-phase 3-wire, single phase 2-wire, and 2-phase 3-wire systems.
  4. Konnessjonijiet tas-Sensor: Connect engine sensors (temperature, oil pressure, fuel level) and other auxiliary sensors to their respective inputs.
  5. Konnessjonijiet tal-Ħruġ: Connect the start, fuel, and auxiliary relay outputs to the appropriate actuators (e.g., starter motor, fuel solenoid).
  6. Portijiet tal-Komunikazzjoni: If using, connect the USB port for PC configuration or the RS485 port for remote communication. Connect the GSM module if SMS functionality is desired.
  7. L-ertjar: Ensure proper grounding of the controller and associated equipment to prevent electrical hazards and interference.
  8. Konfigurazzjoni Inizjali: After wiring, power on the controller and perform initial configuration via the front panel or PC software. Set parameters such as system type, voltage/frequency, and protection thresholds.

Importanti: All wiring should be performed by qualified personnel in accordance with local electrical codes and safety standards. Refer to the detailed wiring diagram for precise terminal assignments.

4. Istruzzjonijiet Operattivi

The HGM9310MPU controller offers various operating modes to manage your genset. Familiarize yourself with the control panel and its functions.

Quddiem view of the HGM9310MPU Generator Controller

Immaġni: Front ċar view of the HGM9310MPU Generator Controller, showing the LCD screen, navigation buttons (up, down, left, right, Enter, Esc), and control buttons (Stop, Auto, Manual, Alarm Mute, Start).

Quddiem view of the HGM9310MPU Generator Controller with screen active

Immaġni: A quddiem view of the HGM9310MPU Generator Controller with its LCD screen active, displaying operational data. Note: The text on the screen in this image is in Chinese, but the controller supports multiple languages including English.

Control Panel Matulview:

  • Display LCD: Shows real-time operational data, alarms, and menu options.
  • Buttuni tan-Navigazzjoni: Used to navigate through menus and adjust settings (Up, Down, Left, Right, Enter, Esc).
  • Buttuna STOP: Stops the generator and resets alarms.
  • Buttuna AUTO: Puts the controller in automatic mode, enabling automatic start/stop based on remote signals or mains status (for HGM9320MPU).
  • Buttuna MANWALI: Allows manual control of the generator.
  • ALARM MUTE Button: Silences audible alarms.
  • Buttuna START: Initiates manual start sequence for the generator.

Modi Operattivi Bażiċi:

  1. Modalità Manwali:
    • Agħfas il- MANWAL buttuna.
    • Agħfas il- BIDU button to manually start the generator.
    • Agħfas il- STOP button to manually stop the generator.
  2. Automatic Mode (HGM9310MPU):
    • Agħfas il- AUTO buttuna.
    • The controller will monitor remote start signals. Upon receiving a valid signal, it will initiate the automatic start sequence.
    • The generator will stop automatically when the remote start signal is removed.
  3. Automatic Mains Failure (AMF) Mode (HGM9320MPU only):
    • Agħfas il- AUTO buttuna.
    • The controller continuously monitors the mains supply.
    • If the mains supply fails, the controller will automatically start the generator and transfer the load.
    • When mains power is restored, the controller will transfer the load back to the mains and shut down the generator after a cool-down period.

For detailed menu navigation, parameter setting, and advanced functions like scheduled start/stop or PLC programming, please consult the comprehensive user manual.

5. Manutenzjoni

Regular maintenance ensures the longevity and reliable performance of your HGM9310MPU controller and the genset it manages. Always disconnect power before performing any maintenance.

Linji Gwida Ġenerali għall-Manutenzjoni:

  • Tindif: Periodically clean the controller's display and panel with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the acrylic screen or silicon buttons.
  • Verifika tal-Konnessjonijiet: Regularly inspect all wiring connections for tightness and corrosion. Loose connections can lead to intermittent operation or faults.
  • Aġġornamenti tal-Firmware: Iċċekkja l-manifattur website for any available firmware updates. Updates can improve performance, add features, or resolve known issues.
  • Verifika tal-Parametru: Periodically verify that all configured parameters (e.g., voltage thresholds, delay timers) are still correct and meet operational requirements.
  • Iċċekkja tal-batterija: Ensure the genset's battery, which powers the controller, is in good condition and properly charged.
  • Spezzjoni Ambjentali: Ensure the controller's operating environment remains within specified temperature and humidity ranges. Check for any signs of moisture ingress or excessive dust accumulation.
  • Event Log Review: Regolarment mill-ġdidview the controller's event log for any recurring alarms or warnings. This can help identify potential issues before they become critical failures.

For specific maintenance schedules and procedures related to the genset itself, refer to the genset manufacturer's manual.

6 Issolvi l-problemi

This section provides basic troubleshooting steps for common issues. For complex problems or persistent faults, contact technical support.

Xenarji Komuni ta' Soluzzjoni ta' Problemi
ProblemaKawża PossibbliSoluzzjoni
Id-displej tal-kontrollur huwa vojt.No power supply; Incorrect wiring; Blown fuse.Check DC power input (8-35V); Verify wiring connections; Check and replace fuses if necessary.
Il-ġeneratur ma jixgħelx fil-modalità AUTO.No remote start signal; Low battery voltage; Fuel level low; Engine fault.Verify remote start signal; Check battery voltage; Ensure adequate fuel; Check engine for faults (e.g., oil pressure, temperature).
Indikazzjoni ta' allarm fuq il-wiri.Specific fault detected (e.g., over voltage, low oil pressure).Note the alarm message; Refer to the full manual's alarm list for specific causes and remedies; Press ALARM MUTE to silence.
Incorrect readings (voltage, frekwenza, eċċ.).Sensor malfunction; Incorrect parameter settings; Wiring issue.Check sensor connections; Verify calibration parameters in controller settings; Inspect wiring for damage or loose connections.
Controller not communicating via USB/RS485.Incorrect cable; Driver issues; Software settings; RS485 address conflict.Ensure correct USB/RS485 cable; Install necessary drivers; Verify software communication settings; Check RS485 addresses.

Always consult the detailed alarm list and troubleshooting guide in the complete user manual for comprehensive solutions.

7. Speċifikazzjonijiet

Technical specifications for the HGM9310MPU Generator Controller.

Specifications table for HGM93XX MPU(CAN) series controllers

Immaġni: A table outlining the detailed specifications of the HGM93XX MPU(CAN) series, including operating voltage, power consumption, alternator input range, frequency, speed sensor voltage/frequency, relay outputs, case dimensions, panel cutout, working conditions, storage conditions, protection level, insulating intensity, and net weight.

HGM9310MPU Technical Specifications
OġġettKontenut
Vol OperattivtageDC8.0V to DC35.0V, Continuous Power Supply.
Konsum tal-Enerġija<4W (standby <2W)
<4W (standby <2W)AC15V-AC 360V (ph-N)
3-Fażi 4-WajerAC30V - AC620V (ph-ph)
3-Fażi 3-WajerAC15V - AC360V (ph-N)
Single-Phase 2-WireAC15V - AC360V (ph-N)
2-Fażi 3-Wajer50Hz/60Hz
Frekwenza tal-Alternatur1.0V sa 24.0V (RMS)
Sensor tal-veloċità Voltage10,000 Hz (mass.)
Frekwenza tas-Sensor tal-Veloċità16A DC28V supply output
Start Relay Output16A DC28V supply output
Ħruġ tar-Relay tal-Fjuwil7A DC28V supply output
Auxiliary Relay Output (1)7A DC28V supply output
Auxiliary Relay Output (2)7A DC28V supply output
Auxiliary Relay Output (3)7A DC28V supply output
Auxiliary Relay Output (4)7A AC250V voltage output b'xejn
Auxiliary Relay Output (5)7A AC250V voltage output b'xejn
Auxiliary Relay Output (6)7A AC250V voltage output b'xejn
Dimensjoni tal-Każ237 mm x 172 mm x 45 mm
Qtugħ tal-Panew214mmx160mm
C.T. Secondary5A ratata
Kundizzjonijiet tax-XogħolTemperature: (-25~+70)°C; Humidity: (20~93)%RH
Kundizzjoni tal-ĦażnaTemperatura: (-25 ~ + 70) °C
Livell ta' ProtezzjoniSiegla IP55
Intensità iżolantiApplika AC2.2kV voltage bejn vol għolitage terminali u vol baxxtage terminal; Il-kurrent tat-tnixxija mhuwiex aktar minn 3mA fi żmien 1min.
Piż Nett0.85kg

8. Garanzija u Appoġġ

SMARTGEN products are manufactured to high quality standards. For warranty information and technical support, please refer to the official SMARTGEN webis-sit jew ikkuntattja lin-negozjant awtorizzat tiegħek.

Informazzjoni ta' Kuntatt:

  • For technical assistance, troubleshooting, or warranty claims, please contact SMARTGEN customer support.
  • Refer to the contact details provided with your purchase or visit the official SMARTGEN webis-sit għall-aktar informazzjoni ta' appoġġ aġġornata.

Please have your product model number (HGM9310MPU) and purchase details ready when contacting support.

Dokumenti Relatati - HGM9310MPU

Preview Manwal tal-Utent tal-Kontrollur tal-Ġenerat tas-Serje SmartGen HGM93XXMPU(CAN)
Dan il-manwal tal-utent jipprovdi informazzjoni komprensiva dwar il-kontrolluri tal-ġenset tas-serje SmartGen HGM93XXMPU(CAN). Jiddeskrivi l-karatteristiċi, l-ispeċifikazzjonijiet, it-tħaddim, il-wajers, il-mekkaniżmi ta' protezzjoni, u s-soluzzjoni tal-problemi għal dawn is-sistemi avvanzati ta' kontroll awtomatiku tal-ġenset, iddisinjati għal ġestjoni affidabbli u effiċjenti tal-ġeneratur.
Preview Manwal tal-Utent tal-Kontrollur tal-Ġenerat SmartGen HGM9310MPU/9320MPU/9310CAN/9320CAN
Manwal komprensiv għall-utent għall-kontrolluri tal-ġensets tas-serje SmartGen HGM9310MPU, HGM9320MPU, HGM9310CAN, u HGM9320CAN. Ikopri l-karatteristiċi, l-ispeċifikazzjonijiet, it-tħaddim, il-protezzjoni, il-wajers, u s-soluzzjoni tal-problemi għall-awtomazzjoni u l-monitoraġġ tal-ġeneratur.
Preview Manwal tal-Utent tal-Kontrollur tal-Ġenerat tas-Serje SmartGen HGM93XXMPU(CAN)
Manwal tal-utent għall-kontrolluri tal-ġenestiċi tas-serje SmartGen HGM93XXMPU(CAN) (HGM9310MPU, HGM9320MPU, HGM9310CAN, HGM9320CAN). Ikopri l-awtomazzjoni, il-monitoraġġ, il-protezzjoni, l-ispeċifikazzjonijiet, u t-tħaddim għas-sistemi ta' kontroll tal-ġeneraturi.
Preview Manwal tal-Utent tal-Kontrollur tal-Ġenerat Parallelat SmartGen HGM9510N/HGM9530N
Manwal komprensiv għall-utent għall-kontrolluri tal-ġensets paralleli SmartGen HGM9510N u HGM9530N. Tgħallem dwar il-karatteristiċi, it-tħaddim, l-ispeċifikazzjonijiet, il-wajers, il-protezzjoni, u l-ikkummissjonar għal sinkronizzazzjoni u kontroll effiċjenti tal-ġeneratur.
Preview Manwal għall-Utent tal-Kontrollur tal-Ġenset SmartGen MGC100
Manwal tal-utent għall-Kontrollur tal-Ġenset SmartGen MGC100, li jiddeskrivi l-karatteristiċi, l-ispeċifikazzjonijiet, it-tħaddim, il-konnessjonijiet, il-parametri u s-soluzzjoni tal-problemi għall-ġestjoni tal-ġenset.
Preview Manwal tal-Utent tal-Kontrollur tal-Ġenerat Smartgen HGM7211/HGM7221
Dan il-manwal tal-utent jipprovdi dettalji komprensivi dwar il-kontrolluri tal-ġensets tas-serje Smartgen HGM7211 u HGM7221. Dawn l-unitajiet avvanzati huma ddisinjati għal tħaddim u monitoraġġ awtomatizzat ta' ġensets ta' unità waħda, li jippermettu bidu/waqfien awtomatiku, kejl tad-dejta, protezzjoni tal-allarm, u komunikazzjoni mill-bogħod.