1. Introduzzjoni
This manual provides essential instructions for the safe and efficient operation, installation, and maintenance of your Geko G00945 12V DC Self-Distributing Diesel Transfer Pump. Please read this manual thoroughly before using the pump to ensure proper function and to prevent injury or damage.
The Geko G00945 pump is designed for transferring diesel fuel. It is characterized by its durability and solid performance, constructed from high-quality materials.
2. Istruzzjonijiet tas-Sigurtà
WARNING: Failure to follow these safety instructions may result in fire, explosion, electric shock, or serious injury.
- Fjuwil tad-Diżil: Handle diesel fuel with extreme care. It is flammable. Do not smoke or use open flames near the pump or fuel.
- Ventilazzjoni: Operate the pump in a well-ventilated area to avoid accumulation of fuel vapors.
- Konnessjoni Elettrika: Ensure the 12V DC power source is correctly connected (positive to positive, negative to negative). Incorrect polarity can damage the pump.
- Sors tal-Enerġija: Use only a 12V DC power source. Do not connect to AC power.
- Is-sħana żejda: Do not run the pump dry for extended periods. Allow the pump to cool down if it becomes excessively hot.
- Manutenzjoni: Skonnettja l-enerġija qabel ma tagħmel xi manutenzjoni jew tindif.
- Tfal u Persunal Mhux Awtorizzat: Żomm lit-tfal u lill-persuni mhux awtorizzati 'l bogħod mill-pompa waqt it-tħaddim.
- Tagħmir Protettiv Personali: Wear appropriate personal protective equipment (PPE) such as gloves and eye protection when handling fuel.
- Użu Intenzjonat: This pump is designed for diesel fuel transfer only. Do not use it for gasoline, alcohol, corrosive liquids, or water.
3. Prodott Aktarview u Komponenti
The Geko G00945 is a compact 12V DC self-distributing pump designed for efficient diesel transfer. Key components include the pump body, motor, inlet/outlet ports, power cables, and an on/off switch.

Figura 3.1: Angolat view of the Geko G00945 pump, showing the red handle, motor housing, and brass hose connectors.

Figura 3.2: Ġenb view of the Geko G00945 pump, highlighting the pump head and mounting bracket.

Figura 3.3: Quddiem view of the Geko G00945 pump, showing the integrated on/off switch and power cables.

Figure 3.4: Included accessories, typically consisting of hose connectors, seals, and battery clamps għall-konnessjoni tal-enerġija.
Komponenti Inklużi:
- Geko G00945 12V DC Diesel Transfer Pump
- Brass hose connectors (typically 2 units)
- Sealing rings/gaskets
- Battery clamps (for 12V DC power connection)
- Inlet filter (strainer)
4. Setup u Installazzjoni
- Immuntar tal-Pompa:
Secure the pump to a stable, flat surface using the integrated mounting bracket. Ensure the pump is positioned to allow for proper hose routing and ventilation. Use appropriate fasteners (not always included).

Figura 4.1: In-naħa ta’ taħt view showing the mounting bracket with pre-drilled holes for secure installation.
- Konnessjoni tal-manka:
- Attach the brass hose connectors to the pump's inlet and outlet ports. Ensure sealing rings are correctly seated to prevent leaks.
- Connect a suitable suction hose (inlet) to the inlet port and a discharge hose (outlet) to the outlet port. Use hose clamps to secure all connections tightly.
- Install the inlet filter (strainer) at the end of the suction hose that will be submerged in the diesel tank. This prevents debris from entering the pump.
- Konnessjoni Elettrika:
- Ensure the pump's on/off switch is in the "OFF" position.
- Connect the red power cable from the pump to the positive (+) terminal of a 12V DC battery.
- Connect the black power cable from the pump to the negative (-) terminal of the 12V DC battery.
- Uża l-batterija pprovduta clamps for a secure connection. Verify polarity before proceeding.
5. Istruzzjonijiet Operattivi
- Preparazzjoni:
- Kun żgur li l-konnessjonijiet kollha tal-pajpijiet huma sikuri u ħielsa minn tnixxijiet.
- Place the inlet hose with the filter into the diesel source tank.
- Position the discharge hose into the receiving tank, ensuring it is securely placed to prevent spills.
- Priming (if necessary):
This pump is self-distributing (self-priming), meaning it can draw fuel without manual priming. However, for initial use or if the pump has been run dry, it may take a few moments for fuel to flow. Ensure the inlet hose is fully submerged.
- Tibda tal-Pompa:
Flip the on/off switch on the pump to the "ON" position. The pump will begin to operate, and fuel should start flowing shortly.
- Monitoraġġ:
Monitor the fuel transfer process. Do not leave the pump unattended during operation. Check for any leaks or unusual noises.
- Twaqqif tal-Pompa:
Once the desired amount of fuel has been transferred, or if the source tank is empty, flip the on/off switch to the "OFF" position.
- Wara l-Operazzjoni:
- Remove the inlet hose from the source tank.
- Allow any remaining fuel in the hoses to drain into the receiving tank or a suitable container.
- Skonnettja l-kejbils tad-dawl mill-batterija.
6. Manutenzjoni
Regular maintenance ensures the longevity and reliable performance of your Geko G00945 pump.
- Cleaning the Inlet Filter: Periodically inspect and clean the inlet filter (strainer) to remove any accumulated debris. A clogged filter can reduce pump performance.
- Hose and Connection Inspection: Regularly check all hoses and connections for signs of wear, cracks, or leaks. Replace damaged components immediately.
- Konnessjonijiet elettriċi: Żgura cl batterijaamps and power cable connections are clean and tight. Corroded terminals can lead to poor performance or pump failure.
- Ħażna: When not in use, store the pump in a clean, dry place, away from direct sunlight and extreme temperatures. Ensure any residual fuel is drained from the pump and hoses.
- Korp tal-Pompa: Keep the exterior of the pump clean. Do not use harsh chemicals that could damage the housing.
7 Issolvi l-problemi
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Il-pompa ma tibdax. | No power, incorrect electrical connection, faulty switch. | Check battery connections and charge. Verify correct polarity. Ensure switch is "ON". |
| Pump runs but no fuel flows. | Inlet hose not submerged, clogged inlet filter, air leak in suction line, pump not primed. | Ensure inlet hose is fully submerged. Clean filter. Check all suction line connections for tightness. Allow time for self-priming. |
| Rata ta' fluss imnaqqsa. | Clogged inlet filter, kinked hose, low battery voltage, excessive lift height. | Clean inlet filter. Straighten hoses. Check battery voltage. Reduce lift height if possible. |
| Fuel leaks from connections. | Loose connections, damaged seals/gaskets, damaged hose. | Issikka l-pajp kollu clamps and connectors. Replace damaged seals or hoses. |
If problems persist after attempting these solutions, contact the manufacturer or a qualified service technician.
8. Speċifikazzjonijiet
| Karatteristika | Dettall |
|---|---|
| Numru tal-Mudell | G00945 |
| Provvista tal-Enerġija | 12V DC |
| Applikazzjoni | Trasferiment tad-Diżil |
| Tip ta' Pompa | Self-Distributing (Self-Priming) |
| Dimensjonijiet tal-Pakkett | 35 x 35 x 15 ċm |
| Piż tal-oġġett | 4.25 kg |
| Manifattur | Ditta Handlowa GEKO |
| Data L-Ewwel Disponibbli | 5 ta’ Frar 2018 |
9. Garanzija u Appoġġ
Għal informazzjoni dwar il-garanzija jew appoġġ tekniku, jekk jogħġbok irreferi għad-dokumentazzjoni pprovduta max-xiri tiegħek jew ikkuntattja lill-manifattur direttament. Żomm il-prova tax-xiri tiegħek għal talbiet ta' garanzija.
Manufacturer: Firma Handlowa GEKO