Digitus DN-91624S-EA

Manwal tal-Istruzzjonijiet tal-Panel tal-Patch Protett Digitus Cat-6A b'24 Port (DN-91624S-EA)

Model: DN-91624S-EA

1. Introduzzjoni

This manual provides detailed instructions for the installation, operation, and maintenance of your Digitus Cat-6A 24-Port Shielded Patch Panel, model DN-91624S-EA. This patch panel is designed for efficient cable management and reliable network connectivity in 19-inch rack environments, supporting high-speed data transmission up to 10 Gigabit Ethernet (10GBase-T) and Power over Ethernet (PoE+) applications.

2. Informazzjoni dwar is-Sigurtà

3. Kontenut tal-Pakkett

Ivverifika li l-oġġetti kollha huma preżenti fil-pakkett:

4. Prodott Aktarview

The Digitus Cat-6A 24-Port Shielded Patch Panel features 24 RJ45 ports on the front for connecting network devices via patch cables, and LSA (LSA-Plus) termination blocks on the rear for permanent cable installation. The panel is designed for 1U rack mounting and provides robust shielding for enhanced signal integrity.

Quddiem view of the Digitus Cat-6A 24-Port Shielded Patch Panel

Figura 4.1: Quddiem view of the Digitus Cat-6A 24-Port Shielded Patch Panel, showing 24 numbered RJ45 ports and the Cat.6A label.

Wara view of a patch panel showing LSA termination blocks

Figura 4.2: Wara view of a patch panel (illustrative, white variant shown) displaying the LSA termination blocks for connecting network cables.

5. Installazzjoni

5.1. Immuntar tar-rack

  1. Identify an available 1U (1.75 inches) space in your standard 19-inch network or server cabinet.
  2. Align the mounting ears of the patch panel with the rack rails.
  3. Secure the patch panel to the rack using the provided mounting screws. Ensure it is firmly attached.

5.2. Cable Termination (LSA Strips)

The patch panel uses LSA (LSA-Plus) termination blocks, color-coded according to EIA/TIA 568 A and B standards. Ensure you consistently use either standard A or standard B for all connections within your network.

Close-up of LSA termination blocks with terminated network cables

Figura 5.1: Close-up view of LSA termination blocks (illustrative, white variant shown) with network cables properly terminated and secured.

  1. Prepare your Cat-6A network cables by stripping approximately 1-2 inches of the outer jacket, exposing the twisted pairs. Be careful not to damage the wire insulation.
  2. Untwist the pairs minimally, just enough to separate the individual wires.
  3. Refer to the color coding diagram on the LSA block (EIA/TIA 568 A or B).
  4. Place each individual wire into its corresponding slot on the LSA block.
  5. Use an LSA punch-down tool to firmly press each wire into its slot. The tool will simultaneously cut off any excess wire.
  6. Repeat this process for all 24 ports.
  7. After termination, use the provided cable ties to secure the installed cables to the cable management bar at the rear of the patch panel, reducing strain on the LSA connections.
  8. Ensure proper grounding of the patch panel to the rack for optimal shielding.

6. Istruzzjonijiet Operattivi

Once the network cables are terminated on the rear LSA blocks, the patch panel is ready for operation.

  1. Connect standard RJ45 patch cables from your network devices (e.g., computers, servers, switches) to the front RJ45 ports of the patch panel.
  2. Ensure the patch cables are fully inserted and click into place.
  3. The patch panel facilitates organized connections between your network infrastructure and end devices.
Close-up of RJ45 ports with red patch cables connected

Figura 6.1: Close-up view of RJ45 ports (illustrative, white variant shown) with red patch cables connected, demonstrating active network connections.

7. Manutenzjoni

8 Issolvi l-problemi

If you encounter issues with your network connections through the patch panel, consider the following:

ProblemaKawża PossibbliSoluzzjoni
Ebda konnessjoni tan-netwerkLoose patch cable connection
Incorrect LSA termination
Faulty patch cable
Ensure patch cables are fully seated
Verify LSA terminations using a cable tester and re-terminate if necessary
Test with a known good patch cable
Veloċità tan-netwerk bil-modPoor quality patch cable
Improper Cat-6A termination
Interference (lack of proper shielding)
Use certified Cat-6A patch cables
Ensure LSA terminations follow EIA/TIA 568 A/B standards precisely
Verify patch panel and cables are properly shielded and grounded
Konnessjoni intermittentiCable bil-ħsara
Loose LSA termination
Kwistjoni tal-konnettur
Spezzjona u ibdel il-kejbils bil-ħsara
Re-punch loose LSA connections
Check RJ45 ports for damage

9. Speċifikazzjonijiet

KaratteristikaDettall
Numru tal-MudellDN-91624S-EA
Proprjetajiet ta' TrażmissjoniCategory 6A, Class EA
Qasam ta' ApplikazzjoniUp to 500 MHz, 10GBase-T
Norms ComplianceISO/IEC 11801 2nd Ed., EN 50173-1, EIA/TIA 568-C, 802.3af, 802.3at PoE+
Immuntar483 mm (19") cabinet mounting, 1U height
Installazzjoni tal-kejbilLSA strips, color coded according to EIA/TIA 568 A & B
Tip ta' KonnetturRJ45
Dimensjonijiet (L x W x H)19.02 x 4.33 x 1.77 pulzieri (madwar)
Piż3.24 Liri (madwar)

10. Garanzija u Appoġġ

Digitus products are manufactured to high-quality standards and are backed by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official Digitus website. For technical support or assistance, please contact your local Digitus distributor or reseller.

For further information, you may visit the Digitus websit: www.digitus.info

Dokumenti Relatati - DN-91624S-EA

Preview Gwida għall-Installazzjoni tad-DIGITUS Shielded Patch Panel
Gwida komprensiva għall-installazzjoni għal patch panels protetti ta' DIGITUS, li tkopri t-tneħħija tat-tensjoni, it-twaħħil tal-kejbil, u l-proċeduri ta' konnessjoni. Tinkludi speċifikazzjonijiet tal-prodott u informazzjoni dwar il-konformità mar-RoHS.
Preview Manwal tal-Utent tas-Swiċċ PoE Kombinat DIGITUS 16/24FE (PoE) + 2G
Manwal tal-utent għas-Swiċċijiet PoE Kombinati DIGITUS 16/24FE (PoE) + 2G (DN-95342 Rev.2, DN-95343 Rev.2), li jagħti dettalji dwar il-karatteristiċi, il-ħardwer, l-installazzjoni, u l-ispeċifikazzjonijiet għall-konnettività tan-netwerk.
Preview Manwal tal-Utent tas-Swiċċ Gigabit Ethernet Immaniġġjat bi 8 Portijiet DIGITUS | DN-651123, DN-651125
Manwal komprensiv għall-utent għad-DIGITUS 8-Port Managed Gigabit Ethernet Switch (mudelli DN-651123 u DN-651125). Tgħallem dwar il-karatteristiċi tal-prodott, l-ispeċifikazzjonijiet, l-installazzjoni, u l-konfigurazzjoni tan-netwerk.
Preview DIGITUS Field Termination Coupler CAT 6A, 500 MHz Installation Guide
Step-by-step installation guide for the DIGITUS Field Termination Coupler CAT 6A, 500 MHz (DN-93912), including stripping, wire management, and final assembly.
Preview Gwida għall-Installazzjoni Rapida tas-Serje SOHO PRO tal-Housing tal-Ħajt DIGITUS
Istruzzjonijiet pass pass għall-installazzjoni tal-kabinetti tan-netwerk DIGITUS Wall Housing SOHO PRO Series, inklużi l-mudelli DN-49100 sa DN-49105.
Preview DIGITUS Swiċċ Ethernet Industrijali Fast b'4 Portijiet - Gwida għas-Sigurtà u t-Tħaddim
Noti essenzjali dwar is-sigurtà u struzzjonijiet operattivi għad-DIGITUS 4-Port Fast Ethernet Network Switch (DN-651130), swiċċ industrijali, mhux immaniġġjat b'uplink 1 SFP FE.