Kenmore 36C03-333

Logo Kenmore

Kenmore 36C03-333 White-Rodgers Furnace Gas Valve Kit

Manwal ta' Istruzzjoni

1. Prodott Aktarview

This manual provides essential information for the installation, operation, and maintenance of the Kenmore 36C03-333 White-Rodgers Furnace Gas Valve Kit. This is a genuine Original Equipment Manufacturer (OEM) part designed to ensure proper function and safety within your furnace system.

The gas valve kit (part number 36C03-333) is responsible for controlling the gas supply to the furnace burner, a critical component for heating operation.

Kenmore 36C03-333 White-Rodgers Furnace Gas Valve Kit

Image 1.1: Kenmore 36C03-333 White-Rodgers Furnace Gas Valve Kit. This image shows the primary component of the gas valve kit.

2. Informazzjoni Importanti dwar is-Sigurtà

WARNING: Risk of electric shock, gas leak, or fire.

Stop sign with text: Many replacement parts look the same but won't fit your model. Don't be fooled! Check your model number before you buy.

Image 2.1: Compatibility Warning. Always verify that part number 36C03-333 is compatible with your specific furnace model before installation.

3. Kontenut tal-Pakkett

The Kenmore 36C03-333 Gas Valve Kit typically includes the main gas valve and may contain additional components necessary for installation, such as gaskets, fittings, or wiring harnesses. Please refer to your furnace's specific parts diagram or the kit's packaging for a complete list of included items.

Components of Kenmore 36C03-333 Gas Valve Kit

Immaġni 3.1: Eż.ample of Gas Valve Kit Components. The actual contents may vary; consult your specific kit's documentation.

4. Istruzzjonijiet ta 'installazzjoni

Follow these general steps for replacing a furnace gas valve. Always consult your furnace's specific service manual for detailed instructions relevant to your model.

  1. Preparazzjoni: Ensure all safety precautions from Section 2 are followed. Turn off electrical power to the furnace and shut off the gas supply.
  2. Aċċess: Locate the existing gas valve within your furnace. You may need to remove access panels.
  3. Skonnettja l-Wiring: Carefully label and disconnect all electrical wires connected to the old gas valve. Take photos if necessary for reassembly.
  4. Disconnect Gas Lines: Using appropriate wrenches, disconnect the gas supply lines from the old valve. Be prepared for a small amount of residual gas.
  5. Neħħi l-Valv il-Qadim: Unmount and remove the old gas valve from the furnace.
  6. Installa Valv Ġdid: Position the new Kenmore 36C03-333 gas valve in place. Secure it using the original mounting hardware.
  7. Qabbad il-Linji tal-Gass: Reconnect the gas supply lines to the new valve. Use new pipe thread sealant (rated for gas) on all threaded connections. Tighten connections securely but do not overtighten.
  8. Qabbad il-Wiring: Reconnect all electrical wires to the new gas valve, matching them to the labels or photos taken earlier.
  9. Test tan-nixxija: Turn on the main gas supply. Apply a non-corrosive leak detection solution (e.g., soapy water) to all gas connections. Look for bubbles, which indicate a leak. If leaks are found, tighten connections or reapply sealant until no bubbles appear.
  10. Irrestawra l-Enerġija: Once all connections are secure and leak-free, restore electrical power to the furnace.
  11. Operazzjoni tat-Test: Follow your furnace's startup procedure to test the new gas valve's operation. Observe for proper ignition and flame characteristics.

5. Operazzjoni

The Kenmore 36C03-333 gas valve operates automatically as part of your furnace's control system. When the thermostat calls for heat, the furnace's control board sends a signal to the gas valve to open, allowing gas to flow to the burner. Simultaneously, the igniter (hot surface igniter or pilot light) will ignite the gas, producing heat.

The gas valve will remain open until the thermostat's heat demand is met or a safety limit is tripped, at which point it will close to shut off the gas supply.

6. Manutenzjoni

The gas valve itself is generally a sealed component and does not require routine user maintenance. However, regular maintenance of your overall furnace system is crucial for the longevity and safe operation of all components, including the gas valve.

7 Issolvi l-problemi

If your furnace is not operating correctly after installing the gas valve, or if you suspect an issue with the gas valve, consider the following:

IMPORTANT: For any issues involving gas or complex furnace malfunctions, always contact a certified HVAC professional. Do not attempt repairs beyond your skill level, especially with gas components.

8. Speċifikazzjonijiet

Attribut Dettall
Numru tal-Parti 36C03-333
Manifattur Kenmore (Genuine OEM Part)
Kompatibilità For Kenmore and ICP furnaces (verify with your specific model)
Kwantità tal-Pakkett tal-Oġġett 1
Dimensjonijiet tal-Pakkett 6 x 5 x 5 pulzieri

9. Garanzija u Appoġġ

As a genuine Original Equipment Manufacturer (OEM) part, the Kenmore 36C03-333 Gas Valve Kit is typically covered by the manufacturer's standard warranty for replacement parts. Warranty terms can vary, so it is recommended to retain your proof of purchase and consult Kenmore's official website or customer support for specific warranty details and claims procedures.

For technical support or assistance with installation and troubleshooting, please contact a qualified HVAC professional or Kenmore customer service.