1. Introduzzjoni
This manual provides essential instructions for the proper setup, operation, and maintenance of your Brecknell LPS150 Portable Shipping Scale. Please read this manual thoroughly before using the scale to ensure safe and efficient operation. The LPS150 is designed for shipping, warehouse, and general-purpose weighing applications, offering portability and ease of use.
2. Informazzjoni dwar is-Sigurtà
- Tgħabbix iżżejjed l-iskala lil hinn mill-kapaċità massima tagħha ta' 150 lbs (68 kg).
- Avoid dropping the scale or subjecting it to severe shocks.
- Do not immerse the scale or its components in water or other liquids.
- Use only the provided AC adapter or specified batteries.
- Żomm l-iskala 'l bogħod minn kampi elettromanjetiċi qawwija.
- Ensure the scale is placed on a stable, level surface during operation.
3. X'hemm fil-Kaxxa
Iftaħ il-komponenti kollha mill-pakkett bir-reqqa u vverifika li rċevejt l-oġġetti li ġejjin:
- Weighing Platform with Indicator and Bracket
- Adapter tal-Qawwa AC
- 4 x Batteriji AAA
- Kejbil RS-232
- Manwal għall-Utent (dan id-dokument)

Image 3.1: All components included with the Brecknell LPS150 Portable Shipping Scale.
4. Prodott Aktarview
4.1 Komponenti
The Brecknell LPS150 scale consists of a stainless steel weighing platform and a remote LCD indicator connected by a coiled cable. The indicator features a digital display and control buttons.

Image 4.1: Labeled diagram of the LPS150 scale components.
4.2 Wiri u Kontrolli
The indicator features a 0.63-inch, 5-digit LCD display. The operator keys include:
- ON / OFF / ZERO: Powers the scale on or off, and zeros the display.
- UNITÀ: Changes the weighing unit (lb, kg, lb/oz).
- TARE: Subtracts the weight of a container.
- HOLD / PRINT: Holds the displayed weight or sends data via RS-232.
5. Setup
5.1 Tqegħid
Place the weighing platform on a firm, level, and stable surface. Ensure there are no obstructions around the platform that could interfere with accurate weighing. The indicator can be placed on a desk or mounted to a wall using the included bracket.

Immaġni 5.1: Eż.ample of scale placement with wall-mounted indicator.
5.2 Konnessjoni tal-Enerġija
The LPS150 scale can be powered by either the included AC adapter or four AAA batteries.
- Adapter AC: Connect the AC adapter to the power input port on the indicator and plug it into a standard electrical outlet.
- Batteriji: Open the battery compartment on the back of the indicator and insert four AAA batteries, observing correct polarity.
5.3 Connecting the Indicator to the Platform
Connect the coiled cable from the weighing platform to the corresponding port on the indicator. Ensure the connection is secure.
6. Istruzzjonijiet Operattivi
6.1 Użin Bażiku
- Agħfas il- ON / OFF / ZERO button to power on the scale. The display will show "0.00" when ready.
- Place the item to be weighed gently on the center of the weighing platform.
- Aqra l-piż muri fuq l-LCD.
- Remove the item from the platform. The display should return to zero. If not, press ON / OFF / ZERO to re-zero.

Image 6.1: The LPS150 scale ready for weighing.

Image 6.2: Weighing a package on the LPS150 scale.
6.2 Konverżjoni tal-Unità
To change the weighing unit:
- With the scale on and displaying weight, press the UNITÀ buttuna.
- The display will cycle through available units: pounds (lb), kilograms (kg), and pounds/ounces (lb/oz).
- Release the button when the desired unit is shown.
6.3 Funzjoni tat-tara
The Tare function allows you to subtract the weight of a container, so only the net weight of the contents is displayed.
- Poġġi kontenitur vojt fuq il-pjattaforma tal-użin.
- Stenna li l-piż jistabbilizza ruħu.
- Agħfas il- TARE button. The display will return to "0.00" and the TARE indicator will illuminate.
- Add items to the container. The display will show only the weight of the added items.
- Biex tneħħi t-tara, neħħi l-kontenitur mill-pjattaforma u agħfas il-buttuna TARE buttuna għal darb'oħra.
6.4 Funzjoni ta' Żomm
The Hold function allows you to temporarily freeze the displayed weight, which is useful for weighing large or awkwardly shaped items that might obscure the display.
- Poġġi l-oġġett fuq il-pjattaforma.
- Ladarba l-piż ikun stabbli, agħfas il-buttuna HOLD / PRINT button. The displayed weight will be held, and the HOLD indicator will illuminate.
- To release the held weight, press the HOLD / PRINT buttuna għal darb'oħra.
6.5 RS-232 Communication Setup (for UPS Worldship)
The LPS150 scale includes an RS-232 port for data communication with compatible software, such as UPS Worldship. Correct configuration of both the scale and your computer's serial port is crucial for proper functionality.
6.5.1 Konfigurazzjoni Skala
- Ensure the scale is powered off.
- Agħfas u żomm il- ON / OFF / ZERO buttuna u l- UNITÀ button simultaneously until the display shows "P1". This enters the setup menu.
- Agħfas il- TARE button repeatedly to cycle through the programming parameters (P1, P2, P3, etc.) until you reach P4.
- At P4, press the UNITÀ button to change the setting to 7 (NCI protocol).
- Agħfas il- TARE button to save the P4 setting and advance to P5.
- At P5, press the UNITÀ button to change the setting to 2 (4800 baud rate).
- Agħfas il- TARE button to save the P5 setting and advance to P6.
- At P6, press the UNITÀ button to change the setting to 2 (7E1 data format).
- Agħfas il- ON / OFF / ZERO button to save all settings and exit the setup menu.
6.5.2 Computer Serial Port Configuration (Windows PC)
- Connect the RS-232 cable from the scale indicator to an available serial port on your computer. If your computer does not have a serial port, a USB-to-serial adapter may be required.
- Open Device Manager (search for "Device Manager" in the Windows search bar).
- Expand the "Ports (COM & LPT)" section.
- Identify the COM port assigned to your scale (e.g., COM1, COM3). Double-click on it to open its Properties.
- Go to the "Port Settings" tab and configure as follows:
- Bits kull sekonda: 4800
- Bits tad-data: 7
- Parità: Anki
- Waqqaf Bits: 1
- Kontroll tal-fluss: Xejn
- Click "OK" to save the settings and close Device Manager.
6.5.3 UPS Worldship Configuration
- Open UPS Worldship software.
- Navigate to the "Tools" tab.
- Select "System Preferences" and then click on "Hardware".
- Under the Scale settings, change the "Scale port" to the COM port you identified in Device Manager (e.g., COM1).
- Change the "Scale Type" to "NCI 3835".
- Click "Test Scale" to verify communication. The weight from the scale should now be reported in Worldship.
7. Manutenzjoni
7.1 Tindif
To maintain accuracy and prolong the life of your scale:
- Wipe the platform and indicator with a soft, damp drapp.
- Tużax prodotti tat-tindif li joborxu, solventi, jew kimiċi ħarxa.
- Ensure no liquids enter the indicator or the gaps around the platform.
7.2 Sostituzzjoni tal-batterija
If the scale is powered by batteries and the display becomes dim or erratic, it's time to replace the batteries. Open the battery compartment on the back of the indicator, remove the old batteries, and insert four new AAA batteries, ensuring correct polarity.
8 Issolvi l-problemi
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| L-iskala ma tixgħel. | No power (AC adapter unplugged, batteries dead/incorrectly installed). | Check AC adapter connection. Replace batteries, ensuring correct polarity. |
| Qari mhux preċiż jew instabbli. | Scale not on a level surface; item touching something else; overload; environmental factors (vibrations, drafts). | Ensure scale is level and stable. Re-zero the scale. Remove any obstructions. Do not exceed capacity. |
| Id-displej juri "Err" jew kodiċi ta' żball. | Overload condition; internal error. | Remove weight from platform. Power cycle the scale. If error persists, contact support. |
| RS-232 communication not working with UPS Worldship. | Incorrect scale settings; incorrect computer serial port settings; incorrect Worldship settings; faulty cable. | Review Section 6.5 for detailed configuration steps for the scale, computer, and UPS Worldship. Ensure RS-232 cable is securely connected and not damaged. |
9. Speċifikazzjonijiet
| Karatteristika | Dettall |
|---|---|
| Mudell | LPS150 |
| Kapaċità | 150 lbs (68 kg) |
| Unitajiet tal-użin | lb, kg, lb/oz |
| Wiri | 0.63" (16 mm), 5-digit LCD |
| Daqs tal-Pjattaforma | 15" L x 12" W (381 mm x 305 mm) |
| Kostruzzjoni | Stainless Steel Platform, Mild Steel Understructure, Stainless Steel/ABS Indicator |
| Qawwa | 4 x AAA Batteries or 6 VDC AC Adapter (both included) |
| Interface | RS-232 |
| Piż tal-oġġett | 11 lbs (5 kg) |
| Dimensjonijiet tal-Prodott | 17 x 15 x 2.3 pulzieri (b'kollox) |
10. Garanzija u Appoġġ
Brecknell products are manufactured to high standards and are warranted against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Brecknell websit.
For technical assistance, troubleshooting, or spare parts, please contact Brecknell customer support. Have your model number (LPS150) and purchase information ready when contacting support.
Brecknell Contact Information:
Please refer to the official Brecknell webis-sit jew l-imballaġġ tal-prodott tiegħek għad-dettalji ta' kuntatt l-aktar riċenti.