Introduzzjoni
The Black Box LES1600 Series Console Server provides secure, remote out-of-band access to network devices such as routers, switches, PDUs, and firewalls. Designed for reliable 24/7 uptime, it offers dual Ethernet ports for redundancy, environmental monitoring, power management, and secure access to devices, facilitating remote management and fault recovery.
Karatteristiċi Ewlenin
- Highly affordable, secure, remote network management of eight devices.
- Dual Gigabit Ethernet ports with seamless auto-failover for built-in redundancy.
- Ideal for businesses with remote branches and limited IT staff, as well as co-location data centers.
- Federal Information Processing Standard (FIPS) 140-2 validated module for enhanced security.
- Simple, straight-through cable to Cisco-style serial consoles.
- Four USB 2.0 Ports for managed device OS transfers.
- Built-in digital I/O and high voltage I/O.
Prodott Overview

This image displays an angled view of the Black Box LES1600 Series Console Server, showcasing its compact design and the front panel with network ports.

A close-up view of the front panel, highlighting the two Gigabit Ethernet ports labeled NET1 and NET2, along with status indicator LEDs for power, activity, and I/O.

This image shows one side of the console server, featuring the 'ERASE' button for resetting configurations and a multi-pin connector for digital I/O (DC OUT, GND, OUT1, OUT2, IN1, IN2).

A dettaljata view of the rear panel, displaying the 9-30V DC power input, eight serial console ports (labeled 1-8), and four USB 2.0 ports (labeled A-D).
Setup
Follow these steps for initial setup of your console server:
- Konnessjoni tal-Enerġija: Connect the appropriate 9-30V DC power supply to the power input port on the rear panel (refer to Figure 4).
- Konnessjoni tan-Netwerk: Connect one or both Gigabit Ethernet ports (NET1, NET2) on the front panel to your network infrastructure using standard Ethernet cables (refer to Figure 2).
- Console Connections: Connect your network devices (routers, switches, etc.) to the serial console ports (1-8) on the rear panel using appropriate serial cables (refer to Figure 4). Ensure you use straight-through cables for Cisco-style consoles.
- Apparati USB (Mhux obbligatorji): If needed, connect USB devices for OS transfers or other functions to the USB 2.0 ports (A-D) on the rear panel (refer to Figure 4).
- Konfigurazzjoni Inizjali: Refer to the detailed configuration guide for initial network settings, IP address assignment, and security configurations.
Istruzzjonijiet Operattivi
Once the console server is powered on and connected to the network, you can begin remote management:
- Accessing Devices: Use a secure shell (SSH) client or a web browser to connect to the console server's IP address.
- Ġestjoni tal-Port: From the console server's interface, select the desired serial port to establish a connection with the attached network device.
- Monitoraġġ: Utilize the console server's dashboard for status monitoring, proactive alerting, and environmental data if applicable.
- Ġestjoni tal-Enerġija: If integrated with PDUs, use the console server's interface to manage power to connected devices.
Manutenzjoni
Regular maintenance ensures optimal performance and longevity of your console server:
- Tindif: Naddaf il-barra tal-apparat perjodikament b'ċarruta ratba u niexfa. Tużax prodotti tat-tindif likwidi jew aerosols.
- Aġġornamenti tal-Firmware: Iċċekkja l-manifattur website for the latest firmware updates to ensure security and feature enhancements. Follow update instructions carefully.
- Kundizzjonijiet Ambjentali: Ensure the device is operated within its specified temperature and humidity ranges to prevent overheating or damage.
- Ġestjoni tal-Kejbil: Keep all connected cables neatly organized and secured to prevent accidental disconnections or damage.
Issolvi l-problemi
Jekk tiltaqa' ma' problemi, ikkunsidra l-passi li ġejjin għas-soluzzjoni tal-problemi:
- Ebda Qawwa: Verify the power supply is correctly connected and the power outlet is functional. Check the power indicator LED on the front panel (Figure 2).
- Kwistjonijiet ta' Konnettività tan-Netwerk: Ensure Ethernet cables are securely connected to NET1/NET2 ports and your network. Check network indicator LEDs. Verify IP configuration.
- Cannot Access Console Port: Confirm the serial cable is correctly connected to both the console server and the target device. Ensure the correct serial port settings (baud rate, data bits, parity, stop bits) are configured.
- L-apparat ma jirrispondix: Try power cycling the console server. If issues persist, consider performing a factory reset using the 'ERASE' button (Figure 3), but be aware this will clear all configurations.
- Kwistjonijiet tas-Software: If experiencing software-related problems, consult the detailed user manual or contact technical support.
Speċifikazzjonijiet
| Attribut | Valur |
|---|---|
| Brand | Kaxxa Iswed |
| Serje | LES1600 |
| Numru tal-Mudell | LES1608A |
| Piż tal-oġġett | 2.2 liri |
| Dimensjonijiet tal-Prodott (LxWxH) | 1.5 x 2.75 x 6.75 pulzieri |
| Kulur | Iswed |
| Numru ta' Proċessuri | 1 |
| Tip ta' Memorja tal-Kompjuter | Mhux magħruf |
| Pjattaforma | Linux |
| Apparat tal-Input | Gamepad (Note: This might be a generic specification, actual input is via network/serial) |
| Data L-Ewwel Disponibbli | 24 ta’ Diċembru 2017 |
Garanzija u Appoġġ
For detailed warranty information, technical support, or to purchase extended protection plans, please refer to the official Black Box website or contact their customer service. Protection plans are available for 2-Year and 3-Year durations, as well as a monthly 'Complete Protect' option.
Manifattur: Kaxxa Iswed