Introduzzjoni
This manual provides detailed instructions for the installation, operation, and maintenance of the Trane KIT18110 OEM Upgraded Furnace Control Board Kit. This kit is designed as an American Standard / Trane OEM component for furnace units built after 1995. It includes the control board (CNT07541), ignitor, wire harness, and bracket.
Nota Importanti: For downflow units built in 1999 and earlier, use KIT18109. For all other units built after 1995, use KIT18110.
Informazzjoni dwar is-Sigurtà
TWISSIJA: Installation and servicing of heating, ventilation, and air conditioning (HVAC) equipment can be hazardous due to system pressure, electrical components, and equipment location. Only trained and qualified service personnel should install, repair, or service HVAC equipment.
- Always disconnect all power to the furnace before installing or servicing the control board. Failure to do so can result in electrical shock, personal injury, or death.
- Ensure proper grounding of the furnace and all electrical components.
- Ilbes tagħmir protettiv personali (PPE) xieraq, inklużi nuċċalijiet u ingwanti tas-sigurtà.
- Verify all wiring connections are secure and correct according to the furnace manufacturer's specifications and local electrical codes.
- Taqbeż l-ebda apparat tas-sigurtà.
Kontenut tal-Pakkett
The Trane KIT18110 kit typically includes the following components:
- Integrated Furnace Control Board (CNT07541)
- Ignitor
- Xedd tal-wajer
- Bracket tal-Immuntar
- Istruzzjonijiet għall-installazzjoni

Image: The Trane KIT18110 furnace control board kit, showing the main circuit board, ignitor, and mounting hardware.
Kompatibilità
This kit is an OEM replacement for various American Standard and Trane units built after 1995. It supersedes several older control board models. Always verify compatibility with your specific furnace model before installation.
Replaces / Supersedes Part Numbers:
- CNT-2854 / CNT02854
- CNT-3076 / CNT03076
- CNT-3798 / CNT03798
- CNT-5164 / CNT05164
- CNT-5165 / CNT05165
- CNT-5995 / CNT05995
- BAF00359 / BAF0359 / BAF-0359
- CNT05885 / CNT-5885
- CNT03604 / CNT-3604
- CNT07541 / CNT7541 / CNT-7541
- 50A65-475 / 50A65-475-07
- D341396P05 / D341396P03 / D341213P01 / D341396P01
- 50A65-120 / 50A65-143 / 50A65-288
- And many others.
Commonly Found in Models:
This kit is commonly found in the following A/TDX and A/TUX Gas Furnace Models:
- AUH1B040A9241AA, AUH1B040A9241AB
- AUH1B060A9361AA, AUH1B060A9361AB
- AUH1B080A9421AA, AUH1B080A9421BA, AUH1B080A9421BB
- AUH1C080A9601AA, AUH1C100A9481AA
- AUH1D100A9601AA, AUH1D120A9601AA
- TUH1B040A9241AA, TUH1B040A9241AB
- TUH1B060A9361AA, TUH1B060A9361AB
- TUH1B080A9421AA, TUH1B080A9421BA, TUH1B080A9421BB
- TUH1C080A9601AA, TUH1C100A9481AA
- TUH1D100A9601AA, TUH1D120A9601AA

Image: A stamp indicating "Trane OEM Component," signifying genuine parts.
Installazzjoni / Setup
This procedure is intended for qualified technicians. Refer to your furnace's specific service manual for detailed wiring diagrams and safety precautions.
- Skonnettjar tal-Enerġija: Locate the main power switch for your furnace and turn it OFF. Additionally, turn off power at the circuit breaker or fuse box. Verify power is off using a voltage metru.
- Bord tal-Kontroll tal-Aċċess: Iftaħ il-pannell tal-aċċess tal-forn biex tikxef il-bord tal-kontroll eżistenti.
- Wajers tad-Dokumenti: Before disconnecting any wires, take clear photographs of all existing wiring connections to the old control board. Label wires if necessary to ensure correct re-connection.
- Skonnettja l-Wajers: Skonnettja bir-reqqa l-wajers kollha mill-bord tal-kontroll il-qadim.
- Neħħi l-Bord il-Qadim: Unscrew or unclip the old control board from its mounting location.
- Installa Bord Ġdid: Mount the new Trane KIT18110 control board using the provided bracket and screws. Ensure it is securely fastened.
- Qabbad il-Wiring: Refer to your photographs and the wiring diagram in your furnace manual to connect all wires to the new control board. Pay close attention to terminal markings (e.g., R, W, Y, G, C).
- Install Ignitor: Replace the old ignitor with the new one provided in the kit, ensuring proper seating and connection to the control board via the wire harness.
- Pannelli Sikur: Close and secure all furnace access panels.
- Irrestawra l-Enerġija: Restore power to the furnace at the circuit breaker or fuse box, then turn on the main power switch for the furnace.
- Operazzjoni tat-Test: Initiate a heating cycle to verify proper furnace operation, including ignition, fan operation, and temperature control. Observe for any error codes or unusual behavior.
Operazzjoni
The Trane KIT18110 control board is an integrated furnace control that manages the sequence of operation for your furnace. Once correctly installed, it will automatically control the ignition, fan, and safety functions based on signals from the thermostat and internal sensors. No direct user interaction with the control board is required for normal operation.
Refer to your furnace's user manual for instructions on setting your thermostat and general furnace operation.
Manutenzjoni
The control board itself typically requires no routine maintenance. However, regular maintenance of your furnace system is crucial for its longevity and efficient operation. This includes:
- Sostituzzjoni tal-filtru: Replace or clean your furnace air filter regularly (monthly or as recommended by your furnace manufacturer).
- Spezzjonijiet Annwali: Schedule annual professional inspections and tune-ups for your furnace.
- Ventilaturi Ċari: Ensure all supply and return air vents are unobstructed.
- Burners Nodfa: Keep burner areas clean and free of debris.
Always disconnect power before performing any maintenance on the furnace.
Issolvi l-problemi
The control board features diagnostic LED indicators that can help identify system faults. Consult your furnace's service manual for a detailed list of error codes and their meanings. Common issues and initial checks include:
- No Heat / No Power:
- Check if the furnace power switch is ON.
- Verify the circuit breaker for the furnace has not tripped.
- Ensure the thermostat is set to "Heat" and the temperature is above the ambient room temperature.
- Check for a blown fuse on the control board (if applicable).
- Il-forn mhux qed jaqbad:
- Check the ignitor for cracks or damage.
- Kun żgur li l-valv tal-provvista tal-gass ikun miftuħ.
- Iċċekkja li s-senser tal-fjamma jkun nadif u pożizzjonat sew.
- Il-Fann Mhux Jaħdem:
- Check if the thermostat fan setting is on "Auto" or "On".
- Ensure the air filter is not excessively dirty, restricting airflow.
- Kodiċi ta' Żball: Observe the diagnostic LED on the control board. Count the flashes or refer to the specific pattern to identify the fault code. Consult your furnace manual for the corresponding issue and recommended solution.
If you are unable to resolve an issue, contact a qualified HVAC technician.
Speċifikazzjonijiet
| Numru tal-Mudell tal-Oġġett | KIT18110 |
| Manifattur | Trane |
| Kompatibilità | American Standard / Trane units built after 1995 |
| Kit Jinkludi | Control Board (CNT07541), Ignitor, Wire Harness, Bracket |
| Dimensjonijiet tal-Pakkett | 12.09 x 7.2 x 5.08 pulzieri |
| Piż tal-oġġett | 15.17 uqija |
Informazzjoni dwar Garanzija
Specific warranty details for the Trane KIT18110 control board kit are typically provided by the point of purchase or Trane directly. It is recommended to retain your purchase receipt and consult the official Trane warranty documentation for your specific product. Generally, OEM parts carry a limited warranty against manufacturing defects.
Appoġġ
For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact your authorized Trane dealer or a qualified HVAC service professional. You may also visit the official Trane websit għal riżorsi addizzjonali u informazzjoni ta’ kuntatt.