OWON XSA1015-TG

Manwal tal-Utent tal-Analizzatur tal-Ispettru OWON XSA1015-TG

Model: XSA1015-TG | Frequency Range: 9 kHz - 1.5 GHz

1. Introduzzjoni

The OWON XSA1015-TG is a high-performance spectrum analyzer designed for precise measurement and analysis of electrical signals. This instrument features a 10.4-inch TFT LCD touch screen, a frequency range from 9 kHz to 1.5 GHz, and an integrated tracking generator. It is suitable for various applications including signal distortion analysis, modulation analysis, spectral purity assessment, and EMI pre-compliance testing. This manual provides essential information for the safe and efficient operation of your device.

Key features of the XSA1015-TG include:

  • Firxa tal-Frekwenzi: 9 kHz sa 1.5 GHz
  • Displayed Average Noise Level (DANL): -150 dBm
  • Phase Noise: -85 dBc/Hz @1 GHz and 10 KHz offset
  • Total Amplitude Accuracy: <1.5 dB
  • Minimum Resolution Bandwidth (RBW): 10 Hz
  • Integrated 1.5 GHz Tracking Generator
  • 10.4-inch TFT LCD Display for clear visualization
OWON XSA1015-TG Spectrum Analyzer front view with 150dBm Displayed Average Noise Level text overlay

Figura 1: Quddiem view of the OWON XSA1015-TG Spectrum Analyzer, highlighting its display and control panel.

2. Setup

2.1 Spakkjar u Spezzjoni

Carefully remove the spectrum analyzer from its packaging. Inspect the device for any signs of physical damage that may have occurred during transit. Retain the packaging materials for future transportation or storage.

2.2 Konnessjoni tal-Enerġija

Connect the provided power cord to the AC input on the rear panel of the device. Ensure the power source meets the specified requirements: 100V - 240V AC, 50/60Hz. The power input is located on the rear of the unit, typically near the fuse holder.

Wara u ġenb view of the OWON XSA1015-TG Spectrum Analyzer, showing power input and ventilation

Figura 2: Wara u ġenb views of the spectrum analyzer, illustrating the power input and ventilation.

2.3 Connecting RF Input and Tracking Generator Output

The front panel features the RF Input and Tracking Generator Output connectors. Both are N-type female connectors with a 50 Ω impedance.

  • Input RF: Connect the signal to be analyzed to the RF Input connector. Observe the maximum safe reverse level of +30 dBm / 50 VDC.
  • Tracking Generator Output: Use this connector to output a tracking signal for characterization of devices under test. The maximum safe reverse level is +20 dBm / 50 VDC.
Close-up of the front panel connectors on the OWON XSA1015-TG, showing RF Input and GEN Output

Figura 3: Dettaljat view of the RF Input and Tracking Generator Output connectors on the front panel.

2.4 Portijiet tal-Komunikazzjoni

The rear panel provides various communication ports for external connectivity:

  • USB HOST: For connecting USB storage devices to save data.
  • USB DEVICE: For connecting the analyzer to a computer.
  • LAN: For network connectivity and remote control.
  • VGA: For connecting an external display.
  • Port tal-Earphone: Għall-output tal-awdjo.
  • 10 M Reference Input: 50 Ω, N-type female connector for an external 10 MHz reference clock.
Wara view of the OWON XSA1015-TG Spectrum Analyzer, showing various communication ports

Figure 4: Rear panel of the spectrum analyzer, displaying the communication and reference input ports.

3. Istruzzjonijiet Operattivi

3.1 Powering On and Basic Interface

Press the 'On/Off' button on the front panel to power on the device. The 10.4-inch TFT LCD will display the main measurement interface. The interface is designed with clear color, size, and shape distinctions for buttons and function areas, facilitating quick adjustments.

3.2 Setting Frequency Parameters

To set the frequency range for your measurement:

  1. Agħfas il- FREQ buttuna fuq il-pannell tal-kontroll.
  2. Use the soft keys on the display or the numeric keypad to enter values for:
    • Center Freq: Sets the center frequency of the displayed span.
    • Start Freq: Sets the lowest frequency of the displayed span.
    • Stop Freq: Sets the highest frequency of the displayed span.
    • Ispan: Sets the frequency range displayed on the screen.
  3. Adjust the Resolution Bandwidth (RBW) by pressing the BW button and selecting the desired value. The minimum RBW is 10 Hz.
OWON XSA1015-TG Spectrum Analyzer display showing a signal trace and measurement settings

Figure 5: The spectrum analyzer display showing a typical signal measurement with frequency and ampsettings tal-lititudni.

3.3 L-issettjar Amplitude Parameters

To control the vertical scale of the display:

  1. Agħfas il- AMPTD buttuna.
  2. Aġġusta l- Livell ta 'Referenza to set the top line of the display in dBm.
  3. Aġġusta l- Attenwazzjoni to prevent input overload and optimize the signal-to-noise ratio.

3.4 Using the Tracking Generator

The integrated tracking generator can be used to characterize the frequency response of filters, amplifiers, and other RF components.

  1. Connect the Tracking Generator Output to the input of the device under test (DUT).
  2. Connect the output of the DUT to the RF Input of the spectrum analyzer.
  3. Enable the tracking generator function through the menu.
  4. Set the desired output power level (range: -30 dBm to 0 dBm).
  5. The spectrum analyzer will sweep synchronously with the tracking generator, displaying the DUT's frequency response.

3.5 Saving and Recalling Data

To save measurement data or instrument settings:

  1. Insert a USB storage device into the USB HOST port on the front panel.
  2. Agħfas il- Ħlief buttuna fuq il-pannell tal-kontroll.
  3. Follow the on-screen prompts to save the current trace, screenshot, or instrument settings to the USB device.
  4. To recall saved data, press the Recall button and select the desired file from the USB device.

4. Manutenzjoni

4.1 Tindif

To clean the instrument, use a soft, damp cloth. Do not use abrasive cleaners or solvents that could damage the display or casing. Ensure the device is powered off and disconnected from the power source before cleaning.

4.2 Kundizzjonijiet Ambjentali

For optimal performance and longevity, operate the OWON XSA1015-TG within the following environmental conditions:

  • Temperatura operattiva: 0 °C sa 40 °C
  • Temperatura tal-Ħażna: -20 °C sa 60 °C
  • Ensure adequate ventilation around the device. The rear panel includes heat vents to facilitate rapid heat dissipation during prolonged use.

4.3 Prekawzjonijiet tas-Sigurtà

Osserva l-prekawzjonijiet tas-sigurtà li ġejjin:

  • Do not exceed the maximum safe input levels for the RF Input (+30 dBm / 50 VDC) and Tracking Generator Output (+20 dBm / 50 VDC).
  • The instrument contains no user-serviceable components inside. Refer all servicing to qualified personnel.
  • Żgura ertjar xieraq tal-apparat.

5 Issolvi l-problemi

This section addresses common issues you might encounter with the OWON XSA1015-TG Spectrum Analyzer.

ProblemaKawża PossibbliSoluzzjoni
L-apparat ma jixgħelxNo power supply; Power cord not connected; Blown fuseCheck power cord connection; Verify power outlet; Inspect and replace fuse if necessary (refer to qualified personnel).
Ebda sinjal muriInput signal too low; Incorrect frequency settings; RF input not connectedIncrease input signal level; Adjust Reference Level; Verify frequency span and center frequency; Ensure RF input is securely connected.
Display is frozen or unresponsiveSoftware error; Temporary glitchRestart the device by powering it off and on. If the issue persists, contact support.
Cannot save data to USBUSB drive not recognized; USB drive full or corruptedEnsure USB drive is properly inserted; Try a different USB drive; Format the USB drive (this will erase all data).

If you encounter issues not listed here or if the suggested solutions do not resolve the problem, please contact OWON customer support for further assistance.

6. Speċifikazzjonijiet

The following table details the technical specifications of the OWON XSA1015-TG Spectrum Analyzer.

ParametruSpeċifikazzjoni
MudellXSA1015-TG
Medda ta' Frekwenzi9 kHz - 1.5 GHz
Displayed Average Noise Level (DANL)-150 dBm
Stadju tal-Fażi-85 dBc/Hz @1 GHz, 10 KHz offset
Total Amplititudni Preċiżjoni<1.5 dB
Minimum Resolution Bandwidth (RBW)10 Hz
Tracking Generator Output Frequency Range100 kHz - 1.5 GHz
Tracking Generator Output Power Level Range-30 dBm - 0 dBm
Wiri10.4 pulzieri TFT LCD
Konnettur tal-Input RF50 Ω, N-type female
Tracking Generator Output Connector50 Ω, N-type female
10 M Reference Input50 Ω, N-type female
Portijiet tal-KomunikazzjoniUSB HOST, USB DEVICE, LAN, earphone port, VGA
Provvista tal-Enerġija100V - 240V AC, 50/60Hz
Piż5 kg (madwar 11 lbs)
Temperatura operattiva0°C - 40°C
Temperatura tal-Ħażna-20 °C - 60 °C
ĊertifikazzjoniEMC, IEC 61010-1:2000-1

7. Garanzija u Appoġġ

7.1 Informazzjoni dwar Garanzija

OWON products are typically covered by a limited warranty against defects in materials and workmanship. The specific terms and duration of your warranty may vary based on your region and point of purchase. Please refer to the warranty card included with your product or contact your local OWON distributor for detailed warranty information.

7.2 Appoġġ Tekniku

For technical assistance, troubleshooting, or service inquiries, please contact OWON customer support. You can typically find contact information on the official OWON website or through your product's documentation. When contacting support, please have your product model number (XSA1015-TG) and serial number ready.

Tista' wkoll iżżur il- OWON Store on Amazon għal aktar informazzjoni u riżorsi dwar il-prodott.

Dokumenti Relatati - XSA1015-TG

Preview Руководство пользователя анализатора спектра OWON XSA815-TG с генератором слежения
Данное руководство пользователя содержит подробные инструкции и спецификации для анализатора спектра OWON XSA815-TG с генератором слежения, охватывая настройку, эксплуатацию, измерения и устранение неполадок.
Preview Manwal tal-Utent tal-Analizzatur tal-Ispettru li jinżamm fl-idejn tas-Serje Owon HSA1000
Manwal tal-utent għall-Analizzatur tal-Ispettru li jinżamm fl-idejn tas-Serje Owon HSA1000, li jagħti dettalji dwar l-ispeċifikazzjonijiet, it-tħaddim, il-prekawzjonijiet ta' sigurtà, u s-soluzzjoni tal-problemi għall-mudelli HSA1016, HSA1016-TG, HSA1036, HSA1036-TG, HSA1075, u HSA1075-TG.
Preview Owon SDS1102+ Digital Oscilloscope with Function Generator
Detailed specifications and features of the Owon SDS1102+ Digital Oscilloscope, including its bandwidth, sampling rate, record length, automatic measurements, and waveform generator capabilities. The document also lists included accessories.
Preview Gwida Rapida tas-Serje OWON FDS: Manwal tal-Utent u Istruzzjonijiet għat-Tħaddim
Get started with your OWON FDS Series oscilloscope. This quick guide covers essential setup, safety, and operational details for its oscilloscope, function generator, power supply, and multimeter features. Visit www.owon.com.hk/download for full support.
Preview OWON HDS200 Series SCPI Command Protocol Reference
This document details the Standard Commands for Programmable Instruments (SCPI) protocol for the OWON HDS200 Series oscilloscopes, covering horizontal settings, acquisition, channel configuration, triggering, measurements, and function generator control.
Preview Speċifikazzjonijiet Tekniċi tal-Oxxilloskopju Diġitali tas-Serje Owon FDS
Speċifikazzjonijiet tekniċi dettaljati għall-oxxilloskopji diġitali tas-Serje Owon FDS, inklużi l-mudelli FDS1102 u FDS1102A, li jkopru l-karatteristiċi tal-prestazzjoni, il-funzjonijiet tat-trigger, il-ġenerazzjoni tal-forma tal-mewġa, il-provvista tal-enerġija, u l-kapaċitajiet tal-multimetru.