1. Introduzzjoni
The Megger MIT1525-US is a high-performance insulation resistance tester designed for industrial and scientific applications. It is capable of performing insulation tests up to 15 kV with a maximum resistance measurement of 30 TΩ (Teraohms). This instrument features a full suite of advanced test modes, including Polarization Index (PI), Dielectric Absorption Ratio (DAR), Dielectric Discharge (DD), Step Voltage (SV), and ramp tests, providing comprehensive diagnostic capabilities for electrical insulation systems.
Equipped with an on-board memory, the MIT1525-US allows for data storage and the ability to stream or download test results to a PC or laptop for further analysis and reporting. Its robust design ensures reliable operation in demanding environments, making it an essential tool for electrical maintenance and commissioning.
2. Informazzjoni dwar is-Sigurtà
Always adhere to local and national safety regulations when operating the Megger MIT1525-US. This device is rated CAT IV 1000 V, indicating its suitability for measurements at the source of the low-voltage installation, such as electricity meters and primary overcurrent protection devices. Improper use can lead to serious injury or damage to the equipment.
Prekawzjonijiet Ġenerali tas-Sigurtà:
- Ensure the instrument is in good working condition before use. Inspect test leads for damage.
- Do not operate the tester in wet conditions or in the presence of explosive gases or vapors.
- Always connect the ground lead first and disconnect it last.
- Verify that the circuit under test is de-energized and properly discharged before connecting the tester.
- Ilbes tagħmir protettiv personali (PPE) xieraq, inklużi ingwanti iżolati u nuċċalijiet tas-sigurtà.
- Refer to the specific safety warnings and instructions provided in the full product manual for detailed guidance.
3. Prodott Aktarview u Komponenti
The Megger MIT1525-US is designed for ease of use and durability. Below is an image illustrating the main components and controls of the device.

Immaġni: Quddiem view of the Megger MIT1525-US Insulation Tester. The device features a large LCD with backlight display, clearly showing measurement readings. Key controls include a rotary switch for function selection, navigation buttons for menu interaction, and a prominent red TEST button. Input terminals are color-coded: red for positive, blue for guard, and black for negative. The robust, grey and off-white casing includes a sturdy black handle for portability.
Karatteristiċi ewlenin:
- 30 Teraohm maximum resistance: Capable of measuring extremely high insulation resistance values.
- PI, DAR, DD, SV and ramp test: Comprehensive suite of diagnostic insulation tests.
- Operate from battery or AC source: Flexible power options for continuous operation.
- Rapid charge lithium-ion battery: Ensures quick turnaround and extended field use.
- Safety rated CATIV 1000 V: High safety rating for demanding electrical environments.
4. Setup
Before using the Megger MIT1525-US, ensure it is properly set up and charged. The device operates from an internal rapid-charge lithium-ion battery or directly from an AC power source.
Passi ta' Setup Inizjali:
- Spakkjar: Carefully remove the MIT1525-US from its packaging. Verify all accessories, including test leads and power adapter, are present.
- Iċċarġjar tal-batterija: Connect the supplied AC power adapter to the instrument's power input port and plug it into a suitable AC outlet. Allow the battery to fully charge before first use. The charging indicator on the display will show the charging status.
- Power On/Off: Press and hold the power button to turn the instrument on or off. The LCD backlight will illuminate upon power-on.
- Settings tal-Lingwa u tal-Ħin: Navigate through the menu using the directional buttons to set your preferred language, date, and time. Refer to the on-screen prompts.
- Konnessjoni taċ-Ċomb tat-Test: Connect the appropriate test leads to the corresponding terminals on the instrument (Red for Line/Positive, Black for Earth/Negative, Blue for Guard). Ensure connections are secure.
5. Istruzzjonijiet Operattivi
This section outlines the basic operation and various test modes available on the Megger MIT1525-US.
5.1. Basic Insulation Resistance Test
- Ipprepara ċ-Ċirkwit: Ensure the circuit or equipment to be tested is de-energized, isolated, and safely discharged.
- Qabbad il-wajers tat-test: Connect the red (Line) and black (Earth) test leads to the circuit under test. If using the guard terminal for surface leakage current compensation, connect the blue (Guard) lead.
- Select Test Voltage: Use the rotary switch to select the desired test voltage (e.g., 500V, 1000V, 2500V, 5000V, 10000V, 15000V).
- Ibda t-Test: Agħfas u żomm l-aħmar TEST button. The instrument will apply the selected voltage and display the insulation resistance value.
- Osserva l-Qari: Monitor the LCD for the resistance reading (in MΩ, GΩ, or TΩ). The display will also show the applied test voltage u kurrenti.
- End Test: Irrilaxxa l- TEST button to stop the test. The instrument will automatically discharge the circuit.
5.2. Advanced Test Modes
The MIT1525-US offers advanced diagnostic tests to assess insulation quality over time.
- Indiċi tal-Polarizzazzjoni (PI): Measures the ratio of insulation resistance at 10 minutes to the resistance at 1 minute. A low PI value can indicate insulation degradation.
- Dielectric Absorption Ratio (DAR): Measures the ratio of insulation resistance at 1 minute to the resistance at 30 seconds. Similar to PI, it helps assess insulation condition.
- Dielectric Discharge (DD): Measures the current discharged from the insulation after a test voltage has been applied and then removed. This test is sensitive to localized defects in multi-layer insulation.
- Pass Voltage (SV): Applies a series of increasing test voltages, with resistance measured at each step. This helps detect voltage-dependent insulation weaknesses.
- Ramp Test: Gradually increases the test voltage while monitoring the leakage current. This can pinpoint the voltage at which insulation breakdown occurs.
To access these modes, use the rotary switch or menu navigation as indicated on the instrument's display. Detailed instructions for each advanced test are available in the full product manual.
5.3. Ġestjoni tad-Data
The MIT1525-US includes on-board memory for storing test results. You can review stored data directly on the instrument's display or transfer it to a computer.
- Saving Results: After a test, follow the on-screen prompts to save the results to the internal memory.
- Viewing Stored Data: Use the navigation buttons to access the memory recall function and browse through saved test records.
- Trasferiment tad-Data: Connect the instrument to a PC or laptop using the provided USB cable. Utilize Megger's proprietary software (available for download from the official website) to stream live data or download stored results for analysis, reporting, and archiving.
6. Manutenzjoni
Proper maintenance ensures the longevity and accuracy of your Megger MIT1525-US.
- Tindif: Clean the instrument's casing b'artab, damp cloth. Do not use abrasive cleaners or solvents. Ensure no moisture enters the terminals or display.
- Kura tal-batterija: For optimal battery life, avoid fully discharging the lithium-ion battery frequently. Recharge the battery regularly, especially if the instrument will be stored for an extended period. Store the instrument with a partial charge (around 50%).
- Ħażna: Store the MIT1525-US in a cool, dry place, away from direct sunlight and extreme temperatures. Use the provided carrying case for protection during transport and storage.
- Kalibrazzjoni: Regular calibration by an authorized service center is recommended to maintain measurement accuracy and compliance with industry standards. Refer to Megger's recommendations for calibration intervals.
- Test Leads: Periodically inspect test leads for any signs of wear, cuts, or damage. Replace damaged leads immediately to ensure safety and accurate measurements.
7 Issolvi l-problemi
This section provides solutions to common issues you might encounter with your Megger MIT1525-US.
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| L-istrument ma jixgħelx. | Low or discharged battery; power button not pressed correctly. | Connect to AC power and charge the battery. Ensure the power button is pressed and held until the display illuminates. |
| No reading or "OL" (Overload) displayed during test. | Open circuit; resistance too high for selected range; faulty test leads. | Check test lead connections. Ensure the circuit is complete. The resistance may be higher than the instrument's maximum range (30 TΩ). Inspect and replace test leads if damaged. |
| Qari mhux preċiż. | Poor test lead connection; external interference; instrument needs calibration. | Ensure secure test lead connections. Perform test in an environment free from strong electromagnetic fields. Consider sending the instrument for calibration. |
| Id-displej huwa mċajpar jew qed jitteptep. | Batterija baxxa. | Iċċarġja mill-ġdid il-batterija. |
For issues not listed here, or if the problem persists, contact Megger technical support or an authorized service center.
8. Speċifikazzjonijiet
Detailed technical specifications for the Megger MIT1525-US Insulation Tester.
| Speċifikazzjoni | Valur |
|---|---|
| Brand | Megger |
| Numru tal-Mudell | 1002-909 |
| Tip ta' Kejl | Voltmeter, Insulation Resistance |
| Reżistenza Massima | 30 TΩ |
| Test Voltages | Sa 15 kV |
| Modi tat-Test | PI, DAR, DD, SV, Ramp Test |
| Sors tal-Enerġija | Battery Powered (Rapid charge lithium-ion), AC Source |
| Klassifikazzjoni tas-Sigurtà | CAT IV 1000V |
| Wiri | LCD b'lura ta 'wara |
| Memorja abbord | Yes, with data streaming/download capability |
| Dimensjonijiet tal-Pakkett | 18 x 13.5 x 13 pulzieri |
| Piż tal-oġġett | 22.35 Liri |
| Data L-Ewwel Disponibbli | 17 ta’ Marzu, 2014 |
9. Garanzija u Appoġġ
Megger products are manufactured to high standards and typically come with a manufacturer's warranty covering defects in materials and workmanship. The specific warranty period and terms may vary by region and product model.
For detailed warranty information, technical support, service, or to inquire about calibration services, please refer to the official Megger website or contact their customer service department directly. When contacting support, please have your instrument's model number (MIT1525-US) and serial number ready.
Megger Official Websit: www.megger.com





