Introduzzjoni
This manual provides essential information for the safe and efficient use of your Gikfun Mini DC R385 Water Pump. Please read these instructions carefully before operating the pump and retain this manual for future reference.
Informazzjoni dwar is-Sigurtà
- Do not run continuously: This diaphragm pump is designed for experimental and intermittent use, not for continuous industrial operation. Prolonged continuous use may lead to overheating and damage.
- VoltagFirxa e: Operate the pump within the specified DC 6-12V voltage range. Exceeding this range can cause damage to the motor.
- Kompatibilità Likwida: Ensure the liquid being pumped is compatible with the pump's materials (silicone). Avoid corrosive or highly viscous liquids unless specifically designed for them.
- Konnessjonijiet elettriċi: Ensure all electrical connections are secure and correctly polarized (red wire for positive, white/gray for negative). Incorrect wiring can damage the pump or power source.
- Immuntar: Use the provided mounting brackets to secure the pump, reducing vibration and noise.
- Superviżjoni: Always supervise the pump during operation, especially during initial setup or when used in experimental models.
Prodott Overview
The Gikfun Mini DC R385 Water Pump is a compact diaphragm pump suitable for various small-scale liquid transfer applications. Its design incorporates a black silicone case for shock absorption and noise reduction.

Immaġni: Fuqview of the Gikfun Mini DC R385 Water Pump, showing its compact design and mounting points.
Karatteristiċi ewlenin:
- DC 6-12V operation.
- Maximum flow rate of 1.5-1.8 L/Min.
- Compact size: 95mm(L) x 47mm(W) x 36mm(H).
- Inlet pipe diameter: 5mm.
- Black silicone case for shockproof and silent operation.
- Suitable for experimental models, car washing, watering, and mineral water filling.

Image: The Gikfun Mini DC R385 Water Pump shown with its detachable black mounting brackets, which help secure the pump and reduce vibration.

Immaġni: Close-up view of the motor end of the Gikfun Mini DC R385 Water Pump, highlighting the heat dissipation holes for optimal performance.
Speċifikazzjonijiet
| Parametru | Valur |
|---|---|
| Ħidma Voltage | DC 6-12V |
| Rata massima tal-fluss | 1.5-1.8 L/Min (0.04 Gallons Per Minute) |
| Għoli Massimu ta 'rfigħ | 5 Meters |
| Pump Size (L x W x H) | 95mm x 47mm x 36mm (Approx. 3.74"L x 1.85"W x 1.42"H) |
| Dijametru tal-Pajp tad-Dħul | 5mm (Inner Diameter) |
| Outer Diameter of Nozzles | 8.5mm |
| Materjal | Silicone (for casing) |
| Piż tal-oġġett | 110 Gram (3.88 uqija) |

Image: Detailed dimensions of the Gikfun Mini DC R385 Water Pump, showing length, width, height, and inlet/outlet diameters.
Setup
- Ippakkja: Carefully remove the pump and any accessories from the packaging.
- Waħħal it-tubi: Connect appropriate tubing (with an inner diameter of 5mm) to the inlet and outlet nozzles of the pump. Ensure a snug fit to prevent leaks.
- Pożizzjoni Pompa: Place the pump in a stable location. The black silicone case provides shock absorption, but securing it with the mounting brackets is recommended for long-term use.
- Qabbad l-Enerġija: Connect the red wire to the positive (+) terminal of your DC power supply (6-12V) and the white/gray wire to the negative (-) terminal. Ensure the power supply is off before connecting.
- Submerge Inlet: Place the inlet tube into the liquid source.
- Prepare Outlet: Direct the outlet tube to the desired destination for the liquid.

Image: The Gikfun Mini DC R385 Water Pump connected with clear tubing, demonstrating a typical setup for liquid transfer between containers.
Vidjo ta' Dimostrazzjoni tas-Setup:
Video: A demonstration of connecting the Gikfun R385 Water Pump to tubing and a power source for liquid transfer. This video illustrates the basic setup process.
Istruzzjonijiet Operattivi
- Qawwa Mixgħul: Once all connections are secure and tubing is in place, turn on the DC power supply. The pump should begin to operate.
- Priming: This pump is generally self-priming. If it does not start pumping immediately, ensure the inlet tube is fully submerged and there are no significant air pockets in the tubing. A slight tilt or gentle shaking of the pump may help dislodge air.
- Tissorvelja l-Fluss: Observe the liquid flow. The pump is designed for a maximum flow of 1.5-1.8 L/Min.
- Itfi: When liquid transfer is complete or if you need to stop the pump, turn off the DC power supply.
Vidjo ta' Dimostrazzjoni tal-Operazzjoni:
Video: A demonstration of the Gikfun R385 Water Pump in operation, showing liquid being transferred. This video highlights the pump's functionality and flow.
Manutenzjoni
- Tindif: After use, especially with non-water liquids, flush the pump with clean water to prevent residue buildup.
- Spezzjoni: Periodically inspect the tubing for kinks, cracks, or blockages. Check electrical connections for corrosion or looseness.
- Ħażna: Store the pump in a dry, cool place away from direct sunlight and extreme temperatures.
- Evita Operazzjoni Kontinwa: As noted in safety, avoid running the pump continuously for extended periods to prolong its lifespan.
Issolvi l-problemi
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Il-pompa ma tibdax | No power, incorrect wiring, faulty power supply. | Check power connections, ensure correct polarity, test power supply. |
| No liquid flow or weak flow | Air in system, clogged tubing, inlet not submerged, incorrect voltage. | Ensure inlet is submerged, check for and remove air bubbles, clear any blockages in tubing, verify voltage huwa fi ħdan 6-12V. |
| Ħsejjes jew vibrazzjonijiet eċċessivi | Loose mounting, air in pump, pump running dry. | Securely mount the pump, ensure liquid is flowing, avoid dry running. |
| Tnixxija mill-konnessjonijiet | Loose tubing, incorrect tubing size, damaged nozzle. | Ensure tubing is securely attached, use tubing with 5mm inner diameter, inspect nozzles for damage. |
Garanzija u Appoġġ
For warranty information or technical support, please contact Gikfun customer service through the retailer where the product was purchased or visit the official Gikfun website. Please have your model number (EK1856) and purchase details ready when contacting support.