1. Introduzzjoni
The PeakTech 4095 is a high-precision graphical True RMS bench multimeter designed for accurate electrical measurements in professional and hobbyist settings. This device features a 4-inch TFT color display, offering clear visualization of measurement data, including graphical trends. It supports a wide range of functions, including voltage, current, resistance, capacitance, frequency, and temperature measurements up to 1000 °C. With LAN, USB, and RS-232 interfaces, the PeakTech 4095 facilitates data logging and remote control, making it a versatile tool for various applications.
2. Informazzjoni dwar is-Sigurtà
Please read all safety instructions carefully before operating the device.
- Dejjem segwi r-regolamenti lokali u nazzjonali tas-sigurtà.
- This device is rated for CAT III 300V. Do not exceed the specified voltage and current limits for any input terminal.
- Ensure the multimeter is properly grounded before use, especially when connecting to mains power.
- Do not operate the device if it appears damaged or if the insulation is compromised.
- Use only the test leads and accessories supplied or recommended by PeakTech.
- Before changing functions or ranges, disconnect the test leads from the circuit under test.
- Oqgħod attent ħafna meta taħdem bil-voltages 'il fuq minn 30V AC RMS, 42V peak, jew 60V DC, għax dawn joħolqu periklu ta' xokk elettriku.
- Fuses must be replaced only with the specified type and rating (ceramic fuse).
3. Kontenut tal-Pakkett
Ivverifika li l-oġġetti kollha huma preżenti u bla ħsara meta tiftaħ il-pakkett:
- PeakTech 4095 Bench Multimeter
- Test Leads
- Type K Thermocouple Wire Sensor
- Korda tal-Enerġija
- Cable USB
- Manwal għall-Utent (dan id-dokument)
- Software CD (for DMM Tool and drivers)
4. Prodott Aktarview
4.1 Panel ta 'Quddiem

Figura 1: Quddiem view of the PeakTech 4095 Bench Multimeter, showing the 4-inch TFT display, function buttons, navigation controls, and input terminals.
The front panel features the 4-inch TFT color display, which shows measurement values, graphs, and menu options. To the right of the display are the primary function buttons (Save, Record, Math, Utility, Port, Run/Stop) and navigation controls (Range, up/down/left/right arrows, Enter). Below the display are additional function buttons (Graph, Dual, V=, A=, Ω, Freq, Temp). On the far right are the input terminals for various measurements: HI/LO for voltage and resistance, 10A RMS for high current, and mA/µA for low current measurements. A USB host port is also located on the front for data storage.
4.2 Panel ta 'wara

Figura 2: Wara view of the PeakTech 4095 Bench Multimeter, showing power input, LAN, USB, RS-232, and external trigger ports.
The rear panel includes the main power input socket, a line selector switch (110V/220V), LAN port for network connectivity, USB device port for PC connection, RS-232 serial port, and external trigger/AUX output ports. Ensure the line selector is set correctly for your region's mains voltage before connecting power.
5. Setup
5.1 Konnessjoni tal-Enerġija
- Before connecting the power cord, verify that the voltage selector switch on the rear panel is set to the correct mains voltage għar-reġjun tiegħek (110V jew 220V).
- Connect the supplied power cord to the power input socket on the rear panel of the multimeter.
- Ipplaggja t-tarf l-ieħor tal-korda tal-enerġija f'sokit tal-enerġija AC ertjat.
- Press the power button on the front panel to turn on the device. The TFT display will illuminate, and the device will perform a self-test.
5.2 Konfigurazzjoni Inizjali
Upon first power-on or after a factory reset, you may need to configure basic settings such as language, date, and time. Navigate through the 'Utility' menu using the front panel buttons to adjust these settings.
6. Istruzzjonijiet Operattivi
The PeakTech 4095 offers various measurement functions accessible via the front panel buttons. Always ensure test leads are connected to the correct input terminals for the desired measurement type.
6.1 Kejl Bażiku
- Voltage (V= / V~): Connect test leads to the HI and LO input terminals. Press the 'V=' button for DC voltage or 'V~' (often combined with V= or selected via a sub-menu) for AC voltage. The device supports True RMS measurements up to 100 kHz.
- Current (A= / A~): For current measurements, connect the test leads in series with the circuit. Use the 10A RMS input for high currents or mA/µA for lower currents. Select 'A=' for DC current or 'A~' for AC current.
- Reżistenza (Ω): Connect test leads to the HI and LO input terminals. Press the 'Ω' button. The device features a fast response time for resistance and continuity tests.
- Test ta' Kontinwità: Select the resistance function and look for the continuity symbol. An audible tone indicates continuity.
- Test tad-Diode: Select the diode test function (often combined with resistance). Connect the test leads to the diode to measure its forward voltagqatra e.
- Frequency (Freq): Connect the signal source to the HI and LO terminals. Press the 'Freq' button to measure the frequency of an AC signal.
- Temperatura (Temp): Connect the Type K thermocouple wire sensor to the dedicated temperature input terminals (if available, or via adapter to HI/LO). Press the 'Temp' button. The device can measure temperatures up to 1000 °C (1372 °C maximum specified).
6.2 Graphical Display and Data Logging
The 4-inch TFT display allows for graphical representation of measurements, such as voltage trends over time. Use the 'Graph' button to switch to graphical mode. The 'Record' button initiates data logging, storing measurement points to internal memory or an external USB drive connected to the front panel port. The device can store up to 1 million measurement points.

Figure 3: Graphical display showing a trend of voltage measurements over time.
6.3 Funzjonijiet Avvanzati
- Funzjonijiet tal-Matematika: The 'Math' button provides access to various mathematical operations on measurement data, such as MIN/MAX, AVG, dB, dBm.
- Utility Menu: The 'Utility' button allows access to system settings, calibration, display options, and interface configurations.
- Wiri Doppju: The 'Dual' button enables simultaneous display of two different measurement parameters or a primary measurement with a secondary parameter (e.g., AC voltage and frequency).
7. Konnettività
The PeakTech 4095 offers multiple interfaces for data transfer and remote control.
- Interface USB: Connect the multimeter to a PC using the USB device port on the rear panel. This allows for data transfer and remote control via software. The front panel USB host port is for connecting USB storage devices for data logging.
- Interface LAN: Connect the multimeter to a network using an Ethernet cable. This enables remote control and data access over a local area network.
- Interface RS-232: The serial RS-232 port on the rear panel provides another option for connecting the multimeter to a PC or other control systems.
For PC connectivity, install the 'DMM Tool' software and drivers from the supplied CD or PeakTech's website. While the software is designed for data acquisition and control, users have reported that specific versions may not be fully updated for the 4095 model's advanced features, particularly for direct PC control and processing of .csv recordings. For detailed instructions on using the software, refer to the software's documentation.
8. Manutenzjoni
8.1 Tindif
Biex tnaddaf l-apparat, uża artab, damp cloth with a mild detergent. Do not use abrasive cleaners or solvents. Ensure the device is powered off and disconnected from all power sources and circuits before cleaning.
8.2 Sostituzzjoni tal-Fjus
If the current measurement function fails, the fuse may need replacement. Refer to the specifications for the correct ceramic fuse type and rating. Fuse replacement should only be performed by qualified personnel. Disconnect the device from all power sources and test leads before attempting to open the casing.
8.3 Kalibrazzjoni
The PeakTech 4095 is factory calibrated. For continued accuracy, periodic calibration by an authorized service center is recommended. Refer to the 'Utility' menu for calibration information.
9 Issolvi l-problemi
- L-apparat ma jixgħelx: Check the power cord connection and ensure the power outlet is functional. Verify the rear panel voltage selector switch is set correctly (110V/220V).
- L-ebda qari jew 'OL' muri: Ensure test leads are correctly connected to the appropriate input terminals and the circuit under test. Check if the measurement range is appropriate for the expected value; try a higher range if 'OL' (Overload) is displayed.
- Incorrect current reading: Check the fuse. Ensure the test leads are connected to the correct current input (10A or mA/µA) and in series with the circuit.
- Connectivity issues (LAN/USB/RS-232): Verify cable connections. Ensure correct drivers are installed on the PC. Check network settings for LAN connectivity.
- Problemi bil-wiri: If the display is dim or flickering, check power supply. If specific segments are missing, contact support.
10. Speċifikazzjonijiet
| Parametru | Valur |
|---|---|
| Numru tal-Mudell | 4095 |
| Wiri | 4-inch TFT Color Display, 60,000 Counts |
| Tip ta' Kejl | Multimetru RMS Veru |
| AC Bandwidth | Sa 100 kHz |
| Logging tad-Data | 1 Million Measurement Points |
| Interfaces | LAN, USB (Device & Host), RS-232 |
| Klassifikazzjoni tas-Sigurtà | CAT III 300V, TÜV/GS, EN-61010-1 |
| Tip ta 'Fjus | Ceramic Fuse |
| Kejl tat-Temperatura | Up to 1372 °C (Type K Thermocouple) |
| Sors tal-Enerġija | Mains Powered (110V/220V selectable) |
| Dimensjonijiet tal-Prodott (L x W x H) | 30 x 24 x 11 ċm |
| Piż tal-oġġett | 3 kg |
| Manifattur | PeakTech |
| Pajjiż ta' Oriġini | Iċ-Ċina |
11. Garanzija u Appoġġ
PeakTech products are manufactured with quality and reliability in mind. For warranty information, please refer to the warranty card included with your product or visit the official PeakTech website. In case of technical issues, questions, or service requests, please contact PeakTech customer support or your local distributor. Ensure you have your product model number (4095) and purchase details available when seeking support.