The Eaton Cutler-Hammer BR120 is a 20 Amp, single-pole, Type BR circuit breaker designed to protect electrical wiring from damage caused by overcurrent, which can result from an overload or a short circuit. This device is crucial for maintaining the safety and integrity of your electrical system.
Key features of the BR120 circuit breaker include:
- AmpKlassifikazzjoni ta' l-età: 20 Amps
- Pole Configuration: Single-pole, 1 inch wide
- Voltage Rating: 120/240 Volts
- Kompatibilità: UL approved replacement for Westinghouse, Challenger, and Bryant load centers.
- Funzjoni: Protects circuits from overheating due to overload and fault currents (short circuits).
2. Informazzjoni dwar is-Sigurtà
TWISSIJA: Electrical shock hazard. Improper installation or maintenance can result in serious injury or death. All electrical work should be performed by a qualified electrician in accordance with all national and local electrical codes.
- Always turn off the main power supply at the service panel before working on any electrical circuits.
- Ivverifika li l-enerġija hija mitfija billi tuża voltagIċċekkja t-tester qabel ma tmiss xi wajers jew komponenti.
- Ensure the circuit breaker's amperage rating matches the circuit's requirements.
- Do not use damaged or modified circuit breakers.
- Ilbes tagħmir protettiv personali (PPE) xieraq, inklużi ingwanti iżolati u nuċċalijiet tas-sigurtà.
- Aċċerta ruħek li l-konnessjonijiet tal-ert u tal-wajers huma xierqa.
3. Installazzjoni
Installation of circuit breakers should only be performed by a qualified electrician. The following steps are for informational purposes and highlight the general process.
- Ipprepara ċ-Ċentru tat-Tagħbija: Ensure the main power to the electrical panel is completely shut off. Open the panel cover.
- Identifika s-Slott: Locate an available slot on the bus bar within the load center.
- Qabbad il-Wajer: Connect the circuit wire (typically black or red) to the terminal screw on the circuit breaker. Ensure the wire is stripped to the correct length and securely tightened. Refer to the breaker's label for wire gauge compatibility and torque specifications.
- Attach Breaker: Hook the rear clip of the breaker onto the retaining clip in the load center.
- Engage Bus Bar: Firmly press the front of the breaker down until it snaps securely onto the bus bar. Ensure it is fully seated.
- Agħlaq il-Panel: Ladarba l-konnessjonijiet kollha jkunu siguri u vverifikati, erġa' poġġi l-għatu tal-pannell.
- Irrestawra l-Enerġija: Ixgħel il-qawwa prinċipali lura.

Stampa 1: Quddiem view of the Eaton Cutler-Hammer BR120 20A circuit breaker, showing the 'On/I' and 'Off/O' markings, the 20 Amp rating, and the Eaton brand logo. This view also displays the UL listing and Type BR designation.

Stampa 2: Angolat view of the BR120 circuit breaker, highlighting the rear clip mechanism used for attachment to the load center's bus bar. The side label with detailed specifications like voltage (120/240V) and wire type (Cu/Al) is also visible.

Stampa 3: Qiegħ view of the BR120 circuit breaker, illustrating the terminal screw where the circuit wire is connected. This screw ensures a secure electrical connection.

Stampa 4: Packaging for the Eaton Cutler-Hammer Type BR 20 Amp Single Pole Circuit Breaker, indicating a quantity of 10. The packaging displays the brand, type, amperage, and compatibility information.
4. Operazzjoni
The BR120 circuit breaker operates with a simple toggle switch:
- ON (I): Pushing the toggle switch to the 'ON' or 'I' position closes the circuit, allowing electricity to flow.
- MITFI (O): Pushing the toggle switch to the 'OFF' or 'O' position opens the circuit, stopping the flow of electricity.
- TRIPPED: If an overload or short circuit occurs, the breaker will automatically move to a tripped position, typically midway between 'ON' and 'OFF', or fully 'OFF' depending on the specific breaker design. This indicates that the circuit has been interrupted for safety.
Biex tirrisettja breaker li jkun qabad:
- First, identify and correct the cause of the trip (e.g., unplug overloaded appliances).
- Move the breaker toggle firmly to the full 'OFF' position.
- Then, move the toggle firmly to the full 'ON' position.
5. Manutenzjoni
Circuit breakers generally require minimal maintenance. However, periodic visual inspection is recommended:
- Spezzjoni Viżwali: Annually, with the main power off, inspect the circuit breakers for any signs of physical damage, discoloration, or loose connections.
- Indafa: Ensure the area around the breakers inside the panel is free from dust and debris.
- Issikkar: Periodically check that terminal screws are tight. Do not overtighten.
If any issues are observed, consult a qualified electrician.
6 Issolvi l-problemi
Din it-taqsima tindirizza kwistjonijiet komuni li tista' tiltaqa' magħhom bis-circuit breaker tiegħek.
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Breaker jivvjaġġa spiss | Overloaded circuit, short circuit, or faulty appliance. | Skonnettja xi apparati miċ-ċirkwit. Spezzjona l-apparat għal difetti. Jekk il-problema tippersisti, ikkonsulta elettriċista. |
| Il-brejker mhux se jerġa' jiġi rrisettjat | Persistent short circuit or internal breaker fault. | Kun żgur li l-apparati kollha fuq iċ-ċirkwit huma skonnettjati. Jekk xorta ma jerġax jiġi rrisettjat, il-brejker jista' jkun difettuż u jeħtieġ li jiġi mibdul minn elettriċista. |
| No power to circuit, but breaker is ON | Loose wiring connection, faulty outlet/switch, or internal wiring issue. | Check connections at outlets/switches. If not resolved, consult a qualified electrician to diagnose the wiring. |
7. Speċifikazzjonijiet
| Speċifikazzjoni | Dettall |
|---|---|
| Brand | Eaton |
| Numru tal-Mudell | BR120 |
| Klassifikazzjoni kurrenti | 20 Amps |
| VoltagKlassifikazzjoni e | 120/240 Volts |
| Tip ta 'Circuit Breaker | Standard, Type BR |
| Tip ta 'Immuntar | Immonta fuq il-Panew |
| Numru Ta' Poli | 1 |
| Materjal | Plastik |
| Dimensjonijiet tal-Prodott | 3 x 2.5 x 1 pulzieri |
| Piż tal-oġġett | 4.8 uqija |
| UPC | 643129363979 |
8. Garanzija u Appoġġ
Deskrizzjoni tal-garanzija: This product comes with a Limited Warranty. For specific terms and conditions, please refer to the warranty documentation provided with your purchase or visit the official Eaton websit.
For technical support, product inquiries, or warranty claims, please contact Eaton customer service. Contact information can typically be found on the Eaton official webis-sit jew fuq l-imballaġġ tal-prodott.