1. Introduzzjoni
This manual provides detailed instructions for the installation, operation, and maintenance of the Inkbird ITC-100VH PID Temperature Controller. The ITC-100VH is designed for precise temperature control in various industrial and scientific applications, offering both PID and ON/OFF control modes with a self-adjusting function for long-term stability.
2. Informazzjoni dwar is-Sigurtà
- Tiżgura l-provvista tal-enerġija voltage matches the controller's specifications (AC 100~240V).
- All wiring should be performed by a qualified electrician to prevent electric shock or damage to the device.
- Do not operate the controller in environments with excessive humidity, dust, corrosive gases, or strong vibrations.
- Skonnettja l-enerġija qabel ma tagħmel xi manutenzjoni jew bidliet fil-wajers.
- This device is not intended for life-support systems or other applications where device malfunction could result in personal injury or property damage.
3. Prodott Aktarview
The Inkbird ITC-100VH is a compact and versatile PID temperature controller featuring a dual digital display for Process Value (PV) and Set Value (SV). It supports multiple temperature sensor types and offers an SSR output for precise control and a relay alarm output for safety or process indication.
Karatteristiċi ewlenin:
- PID and ON/OFF Control Mode with high standard self-adjust function.
- Compatible with multiple temperature sensors like K, S, Wre, T, E, J, B, N, CU50, PT100.
- Display and control accuracy of ±0.2%FS, 0.1°C (<1000°C), 1°C (≥1000°C).
- Intelligent control ensures long-term stability.
- Suitable for devices without water circulation, such as ovens.
Komponenti:

Figura 3.1: Quddiem view of the Inkbird ITC-100VH PID Temperature Controller, showing the dual digital display for PV and SV, and control buttons.

Figura 3.2: Wara view of the controller, illustrating the screw terminals for power, sensor input, and output connections.

Figure 3.3: Model number breakdown for the ITC-100 series, indicating power supply and output configurations. The ITC-100VH model features AC100-240V power, one SSR output, and one relay alarm output.
4. Speċifikazzjonijiet
| Speċifikazzjoni | Valur |
|---|---|
| Numru tal-Mudell | ITC-100VH |
| Dimensjoni tal-Panew ta 'quddiem | DIN 48mm(W) x 48mm(L) |
| Provvista tal-Enerġija Voltage | AC 100 ~ 240V 50/60Hz |
| Vol Operattivtage Firxa | 85~110% Rated voltage |
| Konsum tal-Enerġija | 5VA (approx) |
| PV Character Display | 4 digital 9.9mm height Red LED Letters |
| SV Character Display | 4 digital 8mm height Green LED Letters |
| Preċiżjoni tal-Wiri | ±0.2%FS, 0.1°C (<1000°C), 1°C (≥1000°C) |
| Period of Samplipp | 0.5S |
| Kumpens tat-Temperatura | 0 ~ 50°C |
| Output Prinċipali | Voltage Pulses Output (DC 12V, 30mA) |
| Ħruġ ta' Allarm | AC250V 3A (Resistive load) ON/NC |
| Life Expectancy of Relay | Mechanical ≥10,000,000 operations, Electrical ≥10,000,000 operations |
| Piż | 140g (madwar) |
| Kundizzjonijiet Ambjentali | -10~55°C, RH 35~85% Humidity (no icy or condensation) |
| Temperatura tal-Ħażna | -25~65°C (no icy or condensation) |
| Ħażna tad-Data | 10 snin |
| Daqs tal-qtugħ | 45x45mm |
| Metodu ta 'Immuntar | Flush mounting and screw terminals |
5. Setup u Installazzjoni
The ITC-100VH is designed for flush mounting into a panel. Ensure the cutout size is 45x45mm. Connect the power supply, temperature sensor, and output devices to the appropriate screw terminals on the rear of the controller.
Dijagramma tal-Wiring:
Refer to the diagram on the product label or in Figure 3.3 for correct wiring connections. The ITC-100VH model has an SSR output and a relay alarm output. Ensure all connections are secure and insulated.
Proċess ta' Installazzjoni:
- Prepare a panel cutout of 45x45mm.
- Daħħal il-kontrollur fil-qtugħ minn quddiem.
- Secure the controller using the provided mounting brackets from the rear.
- Connect the power supply (AC 100-240V) to the designated terminals.
- Connect your chosen temperature sensor (e.g., K-type thermocouple, PT100 RTD) to the sensor input terminals. Ensure correct polarity for thermocouples.
- Connect your Solid State Relay (SSR) to the SSR output terminals (DC 12V, 30mA).
- Connect your alarm device to the relay alarm output terminals (AC250V 3A).
- Iċċekkja darbtejn il-konnessjonijiet kollha qabel ma tapplika l-enerġija.
Gwida għall-Installazzjoni Viżwali:
Video 5.1: This video illustrates the assembly and wiring of a temperature control box utilizing a PID temperature controller, showcasing the integration of components. While it features a different model, the general principles of installation and wiring are applicable.
Video 5.2: This video demonstrates the general installation process for a PID temperature controller, including mounting and basic wiring connections. It provides a visual aid for understanding the physical setup.
6. Istruzzjonijiet Operattivi
The Inkbird ITC-100VH features a user-friendly interface for setting and monitoring temperature. The upper display (PV) shows the current process temperature, while the lower display (SV) shows the set target temperature.
Operazzjoni Bażika:
- Qawwa Mixgħul: Once wired correctly, apply power to the controller. The displays will light up.
- Setting Temperature (SV): Agħfas il- SET button to enter the setting mode. Use the arrow keys (▲ / ▼) to adjust the Set Value (SV). Press SET mill-ġdid biex tikkonferma u toħroġ.
- Monitoraġġ: In normal operating mode, the PV display shows the actual temperature, and the SV display shows your target temperature.
- Indikazzjoni tal-Output: The 'OUT' indicator will illuminate when the control output is active. The 'AL1' and 'AL2' indicators will light up when the respective alarms are triggered.
Advanced Settings (Parameter Configuration):
The controller has various parameters for fine-tuning its operation, including sensor type, control mode (PID/ON-OFF), alarm settings, and self-tuning. Accessing and modifying these parameters typically involves pressing and holding the SET button for several seconds to enter the parameter menu. Consult the full technical manual for a complete list of parameters and their functions.
- Tip ta' Sensor: Ensure the controller is configured for the correct sensor type (e.g., K, PT100) to ensure accurate readings.
- PID Auto-Tuning: The self-adjust function (AT/RUN button) can automatically calculate optimal PID parameters for your specific heating/cooling system, improving control accuracy and stability.
- Settings tal-allarm: Configure alarm thresholds and modes (e.g., high limit, low limit) for the relay alarm output.
7. Manutenzjoni
Regular maintenance ensures the longevity and accurate operation of your Inkbird ITC-100VH PID Temperature Controller.
- Tindif: Naddaf il-pannell ta’ quddiem perjodikament b’ċarruta ratba u niexfa. Tużax prodotti tat-tindif jew solventi li joborxu.
- Kontrolli tal-Konnessjoni: Regularly inspect all wiring connections for tightness and signs of corrosion or damage. Loose connections can lead to inaccurate readings or intermittent operation.
- Kundizzjonijiet Ambjentali: Kun żgur li l-ambjent operattiv jibqa' fil-firxiet speċifikati tat-temperatura u l-umdità biex tevita l-ħsara.
- Spezzjoni tas-Sensor: Check the temperature sensor for physical damage or degradation, which can affect measurement accuracy.
8 Issolvi l-problemi
If you encounter issues with your ITC-100VH controller, refer to the following common troubleshooting steps:
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| L-ebda wiri/Mitfi | Ebda provvista tal-enerġija; Wajers mhux korretti; Fjus maħruq | Check power connections; Verify wiring against diagram; Replace fuse if necessary. |
| Qari tat-temperatura mhux preċiż | Incorrect sensor type setting; Faulty sensor; Loose sensor connection; Temperature offset needed | Verify sensor type in settings; Check sensor for damage; Secure sensor wiring; Adjust temperature offset if a consistent deviation is observed. |
| Controller not heating/cooling | Output wiring incorrect; Faulty SSR/relay; Set value not reached; PID parameters incorrect | Check output wiring; Test SSR/relay functionality; Adjust SV; Perform PID auto-tuning. |
| L-allarm mhux qed jattiva | Alarm settings incorrect; Alarm wiring incorrect; Faulty alarm device | Review alarm parameters; Check alarm output wiring; Test alarm device. |
If the problem persists after attempting these solutions, please contact Inkbird customer support.
9. Garanzija u Appoġġ
Garanzija:
The Inkbird ITC-100VH PID Temperature Controller comes with a garanzija ta 'sena from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage caused by misuse, unauthorized modification, accident, or improper installation.
Appoġġ għall-Klijent:
For technical assistance, troubleshooting, or warranty claims, please contact Inkbird customer support through their official website or the retailer where the product was purchased. Please have your model number (ITC-100VH) and purchase information ready when contacting support.