Astralpool 65562

Astral Pool 65562 Victoria Plus Silent 1 CV Single-Phase Filtration Pump User Manual

1. Introduzzjoni

1.1 Prodott Fuqview

The Astral Pool Victoria Plus Silent pump, model 65562, is a high-performance, self-priming filtration pump designed for swimming pools. Engineered with thermoplastic materials, this pump offers enhanced durability and protection. Its design focuses on ease of use and maintenance, while operating at a reduced noise level, typically between 61 dBA and 70 dBA. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your pump.

Astral Pool Victoria Plus Silent pump, side view

Figura 1: Ġenb view of the Astral Pool Victoria Plus Silent pump.

1.2 Informazzjoni dwar is-Sigurtà

Before installing, operating, or performing maintenance on this pump, please read and understand all safety instructions. Failure to follow these instructions could result in serious injury or property damage.

  • Sigurtà Elettrika: Always disconnect power to the pump before servicing. Electrical work should only be performed by a qualified electrician.
  • Sigurtà tal-Ilma: Ensure proper water flow and avoid running the pump dry, as this can cause damage.
  • Sigurtà Kimika: Be aware of pool chemicals and their interaction with pump components.
  • Tfal: Żomm lit-tfal 'il bogħod mill-pompa u l-konnessjonijiet elettriċi.

2. Setup u Installazzjoni

2.1 Pump Placement

Position the pump on a solid, level surface, as close to the pool as possible to minimize friction losses in the suction line. Ensure adequate ventilation around the pump for cooling and easy access for maintenance.

2.2 Konnessjonijiet tal-plaming

Connect the pump to your pool's filtration system using appropriate plumbing fittings. Ensure all connections are watertight to prevent leaks and maintain prime. Use thread sealant on all threaded connections.

2.3 Konnessjoni Elettrika

This pump operates on 230V single-phase power. All electrical wiring must comply with local codes and regulations and should be performed by a licensed electrician. Ensure the pump is properly grounded and protected by a Ground Fault Circuit Interrupter (GFCI) or Residual Current Device (RCD).

3. Istruzzjonijiet Operattivi

3.1 Priming tal-Pompa

Before initial startup or after the pump has been drained, it must be primed. Open the pre-filter lid, fill the basket with water until it overflows, then replace the lid securely. Ensure all valves are open to allow water flow from the pool to the pump.

3.2 Tibda tal-Pompa

Once primed, turn on the power to the pump. The pump should start drawing water and expel air from the system. If the pump does not prime within a few minutes, turn it off, re-prime, and check for air leaks in the suction line.

3.3 Operazzjoni ta 'Kuljum

Operate the pump for a sufficient duration each day to ensure proper filtration of your pool water. The exact duration depends on pool size, bather load, and environmental conditions. Consult your pool professional for recommended run times.

4. Manutenzjoni

4.1 Tindif tal-Qoffa tal-Pre-Filtru

Regularly inspect and clean the pre-filter basket to remove debris. A clogged basket reduces pump efficiency and can lead to damage.

  1. Itfi l-pompa u skonnettja l-enerġija.
  2. Agħlaq kwalunkwe valv meħtieġ biex tevita l-fluss tal-ilma mill-pixxina.
  3. Unscrew the pre-filter lid.
  4. Remove the basket and empty any debris.
  5. Laħlaħ il-basket sewwa bl-ilma.
  6. Inspect the lid O-ring for damage and lubricate if necessary.
  7. Replace the basket and secure the lid tightly.
  8. Erġa' ħejji l-pompa jekk meħtieġ qabel ma terġa' tibdaha.
Fuq view of the Astral Pool Victoria Plus Silent pump showing the pre-filter lid

Figura 2: Fuq view showing the pre-filter lid for cleaning access.

4.2 Winterization

In regions subject to freezing temperatures, the pump must be properly winterized to prevent damage. Drain all water from the pump and plumbing lines. Store the pump in a dry, frost-free location if possible, or follow manufacturer guidelines for in-place winterization.

5 Issolvi l-problemi

This section addresses common issues you might encounter with your pump. For problems not listed here, or if solutions do not resolve the issue, contact a qualified service technician.

ProblemaKawża PossibbliSoluzzjoni
Il-pompa ma tibdaxBla enerġija; interruttur li qata’; problema bil-muturCheck power supply, reset breaker; consult electrician.
Pump runs but does not prime or loses primeLow water level; air leak in suction line; clogged pre-filter; closed valveCheck pool water level; inspect suction line for leaks; clean pre-filter basket; ensure all valves are open.
Rata tal-fluss imnaqqsaClogged pre-filter; dirty main filter; restricted plumbingClean pre-filter basket; backwash or clean main filter; check plumbing for obstructions.
Ħsejjes jew vibrazzjonijiet eċċessiviAir leak; cavitation; worn bearings; loose mountingCheck for air leaks; ensure proper water flow; contact service for worn parts; tighten mounting bolts.

6. Speċifikazzjonijiet

Technical data for the Astral Pool Victoria Plus Silent 1 CV Single-Phase Filtration Pump, Model 65562:

KaratteristikaSpeċifikazzjoni
BrandAstralpool
Numru tal-Mudell65562
Voltage (V)230
Qawwa (CV)1
Capacity (l/h)16,000
Nominal Flow Rate (m³/h)16
MaterjalPlastik (Termoplastiku)
Dimensjonijiet tal-Pakkett69 x 40 x 28 ċm
Piż tal-oġġett10 kg (22.05 lbs)
Sors tal-EnerġijaElettriku tal-AC

7. Garanzija u Appoġġ

Specific warranty details for the Astral Pool 65562 Victoria Plus Silent pump are not provided in this manual. For warranty information, please refer to the documentation included with your purchase or contact Astral Pool directly or your authorized dealer. For technical support or spare parts, please reach out to your supplier or an authorized service center.

Dokumenti Relatati - 65562

Preview Gwida għall-Installazzjoni tad-Doċċa tal-Pixxina AstralPool Niagara
Istruzzjonijiet pass pass għall-installazzjoni tad-doċċa ta' barra AstralPool Niagara, inklużi partijiet, dijagrammi tal-assemblaġġ, u speċifikazzjonijiet tekniċi.
Preview Manwal tal-Installazzjoni u l-Manutenzjoni tal-Għata Awtomatika tal-Pixxina Astralpool Rousillon
Gwida komprensiva għall-installazzjoni u l-manutenzjoni tal-għata awtomatika tal-pixxina Astralpool Rousillon, li tiddeskrivi l-komponenti, ir-rekwiżiti tal-inġinerija ċivili, il-passi tal-assemblaġġ, l-installazzjoni elettrika, u l-karatteristiċi tas-sigurtà.
Preview AstralPool E Series Saltwater Chlorinator Installation Manual
Comprehensive installation, operation, and maintenance guide for the AstralPool E Series Saltwater Chlorinator (E25/E35). Covers safety warnings, system overview, plumbing, electrical connections, water chemistry, operation modes, electrode maintenance, winterizing, and troubleshooting.
Preview Manwal tal-Installazzjoni u l-Manutenzjoni taż-Żennuna tal-Qiegħ Aġġustabbli tal-Astralpool
Gwida komprensiva għall-installazzjoni u l-manutenzjoni taż-Żennuna tal-Qiegħ Aġġustabbli tal-Astralpool, li tkopri l-karatteristiċi tal-prodott, l-installazzjoni pass pass, l-assemblaġġ, il-bidu, u l-ispeċifikazzjonijiet tekniċi għal tindif ottimali tal-pixxina.
Preview Astralpool Winterizer Copper Free: Pool Maintenance Guide
Comprehensive guide to using Astralpool Winterizer Copper Free for complete winter pool maintenance, preventing algae and bacteria growth. Includes product properties, characteristics, instructions, and dosage recommendations.
Preview ASTRALPOOL INVERLONG: Gwida għall-Manutenzjoni tal-Pixxina fix-Xitwa
Gwida komprensiva għal ASTRALPOOL INVERLONG, prodott għall-manutenzjoni tal-pixxini fix-xitwa ddisinjat biex iżomm l-ilma ċar, jipprevjeni l-alka, u jipprepara l-pixxina tiegħek għall-istaġun li jmiss. Tinkludi struzzjonijiet, dożaġġ, u proprjetajiet.