1. Prodott Aktarview
The Orbit RN-50-300 is a rigid nipple designed for use in electrical conduit systems. It provides a secure and durable connection between two threaded conduit components, ensuring proper grounding and protection of electrical wiring. This specific model features a 1/2-inch trade size and a 3-inch length, making it suitable for various standard installations.

Figure 1: Assortment of rigid nipples, similar to the Orbit RN-50-300. The product is a metallic, cylindrical pipe segment with external threads on both ends, used for connecting electrical conduits.
Karatteristiċi ewlenin:
- Mudell: RN-50-300
- Daqs: 1/2 pulzier x 3 pulzier
- Materjal: Typically galvanized steel or other corrosion-resistant metal.
- Applikazzjoni: Electrical conduit systems, providing rigid connections.
- Konformità: Designed to meet industry standards for electrical fittings.
2. Informazzjoni dwar is-Sigurtà
Always follow local electrical codes and safety regulations when installing electrical components. Failure to do so may result in electrical shock, fire, or property damage.
- Ensure power is disconnected before beginning any installation.
- Ilbes tagħmir protettiv personali (PPE) xieraq, inklużi nuċċalijiet u ingwanti tas-sigurtà.
- Use only tools designed for electrical work.
- Ikkonsulta elettriċista kwalifikat jekk m'intix ċert dwar xi parti tal-proċess tal-installazzjoni.
3. Installazzjoni (Setup)
The RN-50-300 rigid nipple is designed for straightforward installation in threaded conduit systems.
- Ipprepara l-Komponenti: Ensure both conduit sections or fittings you intend to connect have clean, properly threaded openings. Remove any burrs or debris.
- Apply Thread Sealant (Optional): For applications requiring a watertight or airtight seal, apply a suitable thread sealant or PTFE tape to the threads of the rigid nipple.
- Thread Nipple: Carefully thread one end of the RN-50-300 rigid nipple into the first conduit component. Hand-tighten initially to ensure proper alignment and prevent cross-threading.
- Qabbad it-Tieni Komponent: Thread the second conduit component onto the other end of the rigid nipple.
- Issikka l-Konnessjonijiet: Use a pipe wrench or appropriate tool to securely tighten both connections. Do not overtighten, as this can damage the threads or components. Ensure the connection is firm and stable.
- Ivverifika l-Konnessjoni: Visually inspect the connection to ensure the nipple is fully engaged and the conduit components are aligned correctly.
4. Operazzjoni
The Orbit RN-50-300 rigid nipple is a passive component and does not have operational controls. Its function is to provide a fixed, rigid connection within an electrical conduit system, facilitating the safe routing and protection of electrical conductors.
Once installed, ensure the conduit system remains intact and free from physical damage or excessive strain that could compromise the integrity of the connections.
5. Manutenzjoni
The RN-50-300 rigid nipple requires minimal maintenance once properly installed. Regular inspections of the conduit system are recommended to ensure long-term performance and safety.
- Spezzjoni Viżwali: Periodically inspect the nipple and surrounding conduit for signs of corrosion, physical damage, or loosening.
- Indafa: Keep the area around the conduit connections clean and free of excessive dust, dirt, or moisture, which could contribute to corrosion.
- Verifika tal-Issikkar: If accessible and safe to do so (with power disconnected), occasionally check the tightness of the connections to ensure they have not vibrated loose over time.
- Sostituzzjoni: If the nipple shows signs of significant corrosion, cracking, or other damage, it should be replaced immediately by a qualified professional.
6 Issolvi l-problemi
As a passive component, troubleshooting for the rigid nipple primarily involves identifying issues related to its installation or integrity within the conduit system.
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Konnessjoni Laxka | Insufficient tightening during installation; vibration over time. | Disconnect power, then re-tighten the nipple connections using appropriate tools. |
| Corrosion/Rust | Exposure to moisture or harsh environments; damaged protective coating. | Replace the nipple if corrosion is severe. Consider using corrosion-resistant fittings or protective coatings in corrosive environments. |
| Damaged Threads | Cross-threading during installation; overtightening; physical impact. | The nipple must be replaced. Ensure proper alignment and avoid overtightening during new installation. |
| Dħul tal-Ilma | Improperly sealed connections; lack of thread sealant in wet locations. | Disconnect power, disassemble, apply appropriate thread sealant (e.g., PTFE tape or pipe dope), and reassemble. Ensure proper drainage if applicable. |
Nota: Always ensure power is disconnected before attempting any troubleshooting or maintenance on electrical conduit systems.
7. Speċifikazzjonijiet
| Attribut | Dettall |
|---|---|
| Numru tal-Mudell | RN-50-300 |
| Brand | Orbit |
| Tip ta' Konnettur | Beżżula |
| Daqs tal-ħajt | 0.5 inch (1/2") |
| Tul | 3 pulzieri |
| Materjal | Galvanized Steel (Typical for rigid nipples) |
| Applikazzjoni | Electrical Conduit Systems |
8. Garanzija u Appoġġ
For specific warranty information and technical support regarding the Orbit RN-50-300 Rigid Nipple, please refer to the official Orbit Industries webis-sit jew ikkuntattja lis-servizz tal-klijenti tagħhom direttament.
Orbit Industries Contact Information:
- Websit: www.orbitindustries.com (Nota: Dan huwa detentur tal-post URL as specific support links were not provided.)
- Servizz tal-Klijent: Jekk jogħġbok iċċekkja l-uffiċjal webis-sit għad-dettalji ta’ kuntatt l-aktar riċenti, inklużi n-numri tat-telefon u l-indirizzi tal-email.
Always retain your purchase receipt for warranty claims.